Service time: Monday to Friday 9:00-18:00
SAC-5P-M12MR/1,94PUR/M12FS 2X4 - SAC-5P-M12MR/1,94PUR/M12FS 2X4 1413021 PHOENIX CONTACT Sensor/actuator cable SAC-5P-M12MR/1,94PUR/M12FS 2X4 ..
In Stock Hot Product

SAC-5P-M12MR/1,94PUR/M12FS 2X4

SAC-5P-M12MR/1,94PUR/M12FS 2X4 1413021 PHOENIX CONTACT Sensor/actuator cable SAC-5P-M12MR/1,94PUR/M12FS 2X4 ..

$0.00USD
4579 in stock
Key Specifications
GTIN:4046356981682
(Cable):No hazardous substances above threshold values
Orderkey:1413021
Packing unit:1
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356981682
(Cable)No hazardous substances above threshold values
Orderkey1413021
Packing unit1
ETIM 4.0 (eCl@ss)EC001855
ETIM 5.0 (eCl@ss)EC001855
ETIM 6.0 (eCl@ss)EC001855
ETIM 7.0 (eCl@ss)EC001855
China RoHS (Cable)Environmentally friendly use period: unlimited = EFUP-e
UNSPSC 13.2 (ETIM)31251501
Custom tariff number85444290
(Ambient conditions)60 V DC
Contact material (General)CuSn
Material, knurls (General)Zinc die-cast, nickel-plated
Sealing material (General)NBR
Coding (Ambient conditions)A - standard
(Standards and Regulations)-25 °C ... 80 °C (cable, flexible installation)
eCl@ss 5.1 (Classifications)27061800
eCl@ss 6.0 (Classifications)27279200
eCl@ss 7.0 (Classifications)27279218
eCl@ss 8.0 (Classifications)27279218
eCl@ss 9.0 (Classifications)27060311
Material of grip body (General)TPU, hardly inflammable, self-extinguishing
Standard designation (Material)M12 connector
Standards/regulations (Material)IEC 61076-2-101
Contact carrier material (General)TPU GF
Contact surface material (General)Ni/Au
Rated voltage (Ambient conditions)48 V AC
Status display (Ambient conditions)No
Length of cable (Key Commercial Data)1.94 m
Cable type (Standards and Regulations)PUR halogen-free black
Wire colors (Standards and Regulations)brown, white, blue, black, green-yellow
Acceleration (Standards and Regulations)10 m/s²
Cable weight (Standards and Regulations)33 kg/km
Degree of pollution (Ambient conditions)3
Halogen-free (Standards and Regulations)in accordance with DIN VDE 0472 part 815
Number of positions (Ambient conditions)5
UL AWM style (Standards and Regulations)20549
Overvoltage category (Ambient conditions)II
Bending radius (Standards and Regulations)50 mm
Insulation resistance (Ambient conditions)≥ 100 MΩ
Standards/regulations (Ambient conditions)M12 connector IEC 61076-2-101
AWG signal line (Standards and Regulations)22
Rated current at 40°C (Ambient conditions)4 A
Traversing path (Standards and Regulations)10 m
Traversing rate (Standards and Regulations)3 m/s
Ambient temperature (operation) (Dimensions)-25 °C ... 90 °C (Plug / socket)
Flame resistance (Standards and Regulations)in accordance with UL 758/1581 FT2
Other resistance (Standards and Regulations)Highly resistant to acids, alkaline solutions and solvents
Resistance to oil (Standards and Regulations)in accordance with DIN EN 60811-2-1
Conductor material (Standards and Regulations)Bare Cu litz wires
Special properties (Standards and Regulations)Flexible cable conduit capable
Test voltage, cable (Standards and Regulations)3000 V
Conductor resistance (Standards and Regulations)max. 58 Ω/km (at 20 °C)
Flammability rating according to UL 94 (General)HB
Insertion/withdrawal cycles (Ambient conditions)≥ 100
Flammability rating according to UL 94 (Material)HB
Insulation resistance (Standards and Regulations)≥ 16 GΩ*km (at 20 °C)
Protective circuit/component (Ambient conditions)unwired
Thickness, insulation (Standards and Regulations)approx. 0.5 mm
External sheath, color (Standards and Regulations)black-gray RAL 7021
Nominal voltage, cable (Standards and Regulations)300 V
Outer sheath, material (Standards and Regulations)PUR
Conductor cross section (Standards and Regulations)5x 0.34 mm² (Signal line)
Number of bending cycles (Standards and Regulations)10000000
Cable type (abbreviation) (Standards and Regulations)PUR
External cable diameter D (Standards and Regulations)4.55 mm ±0.15 mm
Material conductor insulation (Standards and Regulations)PP
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 80 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations)42x 0.10 mm
Core diameter including insulation (Standards and Regulations)1.27 mm ±0.02 mm (Signal line)
Smallest bending radius, fixed installation (Standards and Regulations)23 mm
Smallest bending radius, movable installation (Standards and Regulations)46 mm

Product Description

Sensor/actuator cable, 5-pole, halogen-free PUR, greyish black RAL 7021, Angled male connector M12, coding: coded A, a Straight connection female M12, coding: coded A, cable length: 1.94 m, Customer v
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Sensor/actuator cable, 5-position, PUR halogen-free, black-gray RAL 7021, Plug angled M12, A-coded, on Socket straight M12, A-coded, cable length: 1.94 m, Customer version

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top