Service time: Monday to Friday 9:00-18:00
SAC-5P-M12FS/ 1,5-PUR/M12FS SH - SAC-5P-M12FS/ 1,5-PUR/M12FS SH 1404326 PHOENIX CONTACT Sensor/actuator cable, 5-pos., PUR halogen-free, RAL ..
In Stock Hot Product

SAC-5P-M12FS/ 1,5-PUR/M12FS SH

SAC-5P-M12FS/ 1,5-PUR/M12FS SH 1404326 PHOENIX CONTACT Sensor/actuator cable, 5-pos., PUR halogen-free, RAL ..

$0.00USD
4937 in stock
Key Specifications
GTIN:4046356691062
(Cable):No hazardous substances above threshold values
Orderkey:1404326
(Drawings):
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356691062
(Cable)No hazardous substances above threshold values
Orderkey1404326
(Drawings)
Packing unit1 pc
(Dimensions)IP67
UNSPSC 11 (ETIM)31251501
Country of originPL (Poland)
ETIM 3.0 (eCl@ss)EC001855
ETIM 4.0 (eCl@ss)EC001855
ETIM 5.0 (eCl@ss)EC001855
ETIM 6.0 (eCl@ss)EC001855
ETIM 7.0 (eCl@ss)EC001855
China RoHS (Cable)Environmentally friendly use period: unlimited = EFUP-e
UNSPSC 13.2 (ETIM)31251501
UNSPSC 19.0 (ETIM)31251501
UNSPSC 20.0 (ETIM)31251501
UNSPSC 21.0 (ETIM)31251501
UNSPSC 6.01 (ETIM)31251501
UNSPSC 12.01 (ETIM)31251501
Custom tariff number85444290
UNSPSC 7.0901 (ETIM)31251501
(Ambient conditions)60 V DC
Minimum order quantity50 pc
Contact material (General)CuSn
Length of cable (Drawings)1.5 m
Material, knurls (General)Zinc die-cast, nickel-plated
Sealing material (General)NBR
Coding (Ambient conditions)A - standard
(Standards and Regulations)-25 °C ... 80 °C (cable, flexible installation)
eCl@ss 4.0 (Classifications)27060300
eCl@ss 4.1 (Classifications)27060300
eCl@ss 5.0 (Classifications)27061800
eCl@ss 5.1 (Classifications)27061800
eCl@ss 6.0 (Classifications)27279200
eCl@ss 7.0 (Classifications)27279218
eCl@ss 8.0 (Classifications)27279218
eCl@ss 9.0 (Classifications)27060311
Material of grip body (General)TPU, hardly inflammable, self-extinguishing
Degree of protection (Dimensions)IP65
Contact carrier material (General)TPU GF
Contact surface material (General)Ni/Au
Rated voltage (Ambient conditions)48 V AC
Status display (Ambient conditions)No
Weight per Piece (excluding packing)80.000 g
Shielding (Standards and Regulations)Tinned copper braided shield
Cable type (Standards and Regulations)PUR halogen-free black
Wire colors (Standards and Regulations)Brown, white, blue, black, gray
Acceleration (Standards and Regulations)10 m/s²
Cable weight (Standards and Regulations)43 kg/km
Degree of pollution (Ambient conditions)3
Halogen-free (Standards and Regulations)in accordance with DIN VDE 0472 part 815
Number of positions (Ambient conditions)5
UL AWM style (Standards and Regulations)20549 / 10493 (80°C/300 V)
Overall twist (Standards and Regulations)5 wires around filler to the core
Overvoltage category (Ambient conditions)II
Bending radius (Standards and Regulations)52 mm
Insulation resistance (Ambient conditions)≥ 100 MΩ
AWG signal line (Standards and Regulations)22
Rated current at 40°C (Ambient conditions)4 A
Traversing path (Standards and Regulations)10 m
Traversing rate (Standards and Regulations)3 m/s
Flame resistance (Standards and Regulations)in accordance with UL 758/1581 FT2
Other resistance (Standards and Regulations)Highly resistant to acids, alkaline solutions and solvents
Resistance to oil (Standards and Regulations)in accordance with DIN EN 60811-2-1
Cable abbreviation (Standards and Regulations)LiF9YC11Y
Conductor material (Standards and Regulations)Bare Cu litz wires
Special properties (Standards and Regulations)Flexible cable conduit capable
Conductor resistance (Standards and Regulations)max. 57 Ω/km (at 20 °C)
Flammability rating according to UL 94 (General)HB
Insertion/withdrawal cycles (Ambient conditions)≥ 100
Flammability rating according to UL 94 (Material)HB
Insulation resistance (Standards and Regulations)70 GΩ*km (at 20 °C)
Thickness, insulation (Standards and Regulations)≥ 0.21 mm
External sheath, color (Standards and Regulations)black-gray RAL 7021
Nominal voltage, cable (Standards and Regulations)300 V (at 20 °C)
Outer sheath thickness (Standards and Regulations)approx. 0.5 mm
Outer sheath, material (Standards and Regulations)PUR
Test voltage Core/Core (Standards and Regulations)3000 V (at 20 °C)
Conductor cross section (Standards and Regulations)5x 0.34 mm² (Signal line)
Optical shield covering (Standards and Regulations)80 %
Number of bending cycles (Standards and Regulations)10000000
Cable type (abbreviation) (Standards and Regulations)PUR
External cable diameter D (Standards and Regulations)5.25 mm ±0.2 mm
Material conductor insulation (Standards and Regulations)PP
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 80 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations)42x 0.10 mm
Core diameter including insulation (Standards and Regulations)1.27 mm ±0.02 mm (Signal line)
Dimensional drawingM12 x 1 socket, straight, shielded (Drawings)
Smallest bending radius, fixed installation (Standards and Regulations)26 mm
Smallest bending radius, movable installation (Standards and Regulations)52 mm (up to +60°C)
Schematic diagramPin assignment M12 socket, 5-pos., A-coded, socket side view (Drawings)

Product Description

Sensor/actuator cable, 5 poles, halogen-free PUR, greyish black RAL 7021, shielded, straight connection female M12, coded A, in straight connection female M12, coded A, cable length: 1.5 m
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Dimensional drawingM12 x 1 socket, straight, shielded

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top