| Parameter | Value |
|---|---|
| DeviceNet™ | |
| Type | Plug straight M12 SPEEDCON |
| Coding | A |
| Shielded | yes |
| Bus system | CANopen®/DeviceNet™ |
| Cable type | CANopen®/DeviceNet™, FRNC, black [925] |
| Coding type | A (Standard) |
| Sensor type | CANopen® |
| Cable length | 0.2 m |
| Cable weight | 70 kg/km |
| Locking type | SPEEDCON |
| Product type | Data cable preassembled |
| Test voltage | 2000 V |
| Overall twist | 2 pairs and one drain wire to the core |
| Seal material | NBR |
| Twisted pairs | 2 cores to the pair |
| Status display | No |
| Wave impedance | 120 Ω ±10 % |
| AWG signal line | 24 |
| Contact material | CuSn |
| Conductor material | Tin-plated Cu litz wires |
| Nominal current IN | 4 A |
| Nominal voltage UN | 48 V AC |
| Shield attenuation | < 0.95 dB (At 125 kHz) |
| Single wire, color | red-black, blue-white |
| Conductor structure | 2xAWG24/19+2xAWG22/19 |
| Degree of pollution | 3 |
| Dimensional drawing | |
| Number of positions | 5 |
| Transmission medium | Copper |
| Working capacitance | 39.8 nF |
| Degree of protection | IP65 |
| No. of cable outlets | 1 |
| Overvoltage category | II |
| Signal type/category | CANopen® |
| Insulation resistance | ≥ 0.2 GΩ*km |
| Material of grip body | TPU, hardly inflammable, self-extinguishing |
| External sheath, color | red lilac RAL 4001 |
| Outer sheath, material | FRNC |
| Status display present | No |
| Type of pair shielding | Aluminum-lined polyester foil |
| Conductor cross section | 2x 0.25 mm² (Signal line) |
| External cable diameter | 6.9 mm ±0.3 mm |
| Contact carrier material | TPU GF |
| Contact surface material | Ni/Au |
| Material wire insulation | Cell PE |
| Max. conductor resistance | ≤ 90 Ω/km |
| Material for screw connection | Zinc die-cast, nickel-plated |
| Ambient temperature (operation) | -25 °C ... 80 °C (cable, fixed installation) |
| Conductor structure signal line | 19x 0.12 mm |
| Flammability rating according to UL 94 | HB |
| Smallest bending radius, fixed installation | 110 mm |
Technical specifications and performance data
Installation and operation guide