Service time: Monday to Friday 9:00-18:00
SAC-5P-FY/0,2-925/MS-FS - SAC-5P-FY/0,2-925/MS-FS 1422422 PHOENIX CONTACT Cable bus system SAC-5P-FY/0,2-925/MS-FS 1422422
In Stock Hot Product

SAC-5P-FY/0,2-925/MS-FS

SAC-5P-FY/0,2-925/MS-FS 1422422 PHOENIX CONTACT Cable bus system SAC-5P-FY/0,2-925/MS-FS 1422422

$0.00USD
3973 in stock
Key Specifications
:DeviceNet™
Type:Plug straight M12 SPEEDCON
Coding:A
Shielded:yes
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
DeviceNet™
TypePlug straight M12 SPEEDCON
CodingA
Shieldedyes
Bus systemCANopen®/DeviceNet™
Cable typeCANopen®/DeviceNet™, FRNC, black [925]
Coding typeA (Standard)
Sensor typeCANopen®
Cable length0.2 m
Cable weight70 kg/km
Locking typeSPEEDCON
Product typeData cable preassembled
Test voltage2000 V
Overall twist2 pairs and one drain wire to the core
Seal materialNBR
Twisted pairs2 cores to the pair
Status displayNo
Wave impedance120 Ω ±10 %
AWG signal line24
Contact materialCuSn
Conductor materialTin-plated Cu litz wires
Nominal current IN4 A
Nominal voltage UN48 V AC
Shield attenuation< 0.95 dB (At 125 kHz)
Single wire, colorred-black, blue-white
Conductor structure2xAWG24/19+2xAWG22/19
Degree of pollution3
Dimensional drawing
Number of positions5
Transmission mediumCopper
Working capacitance39.8 nF
Degree of protectionIP65
No. of cable outlets1
Overvoltage categoryII
Signal type/categoryCANopen®
Insulation resistance≥ 0.2 GΩ*km
Material of grip bodyTPU, hardly inflammable, self-extinguishing
External sheath, colorred lilac RAL 4001
Outer sheath, materialFRNC
Status display presentNo
Type of pair shieldingAluminum-lined polyester foil
Conductor cross section2x 0.25 mm² (Signal line)
External cable diameter6.9 mm ±0.3 mm
Contact carrier materialTPU GF
Contact surface materialNi/Au
Material wire insulationCell PE
Max. conductor resistance≤ 90 Ω/km
Material for screw connectionZinc die-cast, nickel-plated
Ambient temperature (operation)-25 °C ... 80 °C (cable, fixed installation)
Conductor structure signal line19x 0.12 mm
Flammability rating according to UL 94HB
Smallest bending radius, fixed installation110 mm

Product Description

Bus system cable, CANopen®, DeviceNet™, 5-position, shielded, Plug straight M12, coding: A SPEEDCON, on Socket straight M12, coding: A SPEEDCON and Plug straight M12, coding: A SPEEDCON, cable length:
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top