| Parameter | Value |
|---|---|
| 60 V DC | |
| Shielded | Yes |
| Feed rate | 3 m/s |
| Screening | Tinned Copper Wire Mesh |
| Cable type | Halogen-free PUR black |
| Plug Cycles | ≥ 100 |
| application | Standard |
| Abbreviation | LiF9YC11Y |
| Acceleration | 10 m/s² |
| Advance path | 10 m |
| Cable Weight | 43 kg/km |
| Cable length | 60 m |
| Codification | to |
| Construction | Free Cable End |
| Line Section | 5x 0.34 mm² (signal conductor) |
| Product Type | Sensor/Actuator Cables |
| UL AWM Style | 20549 / 10493 (80°C/300V) |
| Encoding Type | to |
| Total cabling | 5 conductors around filling as core |
| Bending radius | 52 mm |
| Oil Resistance | according to DIN EN 60811-2-1 |
| Surge Category | Ii |
| AWG Signal Line | 22 |
| Gasket material | NBR |
| Line Resistance | max. 57 Ω/km (at 20 °C) |
| Number of poles | 5 |
| Contact material | CuSn |
| Dimension Scheme | |
| Flame Resistance | according to UL 758/1581 FT2 |
| Protection Index | IP65 |
| Rules/Provisions | IEC 61076-2-101 |
| Special Features | suitable for energy chains |
| Other resistances | Good resistance to acids, alkalis and solvents |
| Outer Wrap, Color | greyish black RAL 7021 |
| Status Indication | No |
| Contact resistance | ≤ 5 mΩ |
| Grip body material | Fire-resistant, self-extinguishing TPU |
| Nominal Current IN | 4 A |
| Nominal voltage UN | 48 V AC |
| Protection Circuit | Unplugged |
| Absence of halogens | according to DIN VDE 0472 part 815 |
| Conductive Material | Naked Cu Conductor |
| Degree of pollution | 3 |
| Visual Screen Cover | 80 % |
| Cable Outer Diameter | 5.25 mm ±0.2 mm |
| Outer Wrap, Material | PUR |
| Single Driver, Color | brown, white, blue, black, grey |
| Insulation resistance | ≥ 100 MΩ |
| Nominal Voltage Cable | 300 V (at 20°C) |
| Number of Cable Outlets | 1 |
| Contact Support Material | TPU GF |
| Denomination of standard | M12 plug-in connector |
| Number of bending cycles | 10000000 |
| Cable Type (abbreviation) | PUR |
| Material: Contact Surface | Ni/AU |
| Screw connection material | Zinc die-cast iron, nickel-plated |
| Wall Thickness Insulation | ≥ 0.21 mm |
| Wall Thickness Outer Wrap | approx. 0.5 mm |
| Line Insulation Resistance | 70 GΩ*km (at 20 °C) |
| Available Status Indication | No |
| Ambient Temperature (Service) | -25 °C ... 80 °C (Cable, movable arrangement) |
| Material: Conductor Insulation | PP |
| Test Voltage Conductor/Conductor | 3000 V (at 20°C) |
| Conductor Construction Signal Cable | 42x 0.10 mm |
| Conductor diameter incl. insulation | 1.27 mm ±0.02 mm (signal conductor) |
| Flammability class according to UL 94 | HB |
| Smaller bending radius, fixed mounting | 26 mm |
| Smaller bending radius, movable mounting | 52 mm (up to +60 °C) |
Technical specifications and performance data