Service time: Monday to Friday 9:00-18:00
SAC-5P-5,0-515/M12FR VA E-UL - SAC-5P-5,0-515/M12FR VA E-UL 1031268 PHOENIX CONTACT Cable for sensors/actuators 5-pin, PVC, black RAL 9005,..
In Stock Hot Product

SAC-5P-5,0-515/M12FR VA E-UL

SAC-5P-5,0-515/M12FR VA E-UL 1031268 PHOENIX CONTACT Cable for sensors/actuators 5-pin, PVC, black RAL 9005,..

$0.00USD
4976 in stock
Key Specifications
EAN:Four trillion fifty five billion six hundred twenty six million five hundred thirty four thousand seven hundred sixty three
(Cable):No dangerous substances above the thresholds
Key order:One million thirty one thousand two hundred sixty eight
(Measures):IP69K
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
EANFour trillion fifty five billion six hundred twenty six million five hundred thirty four thousand seven hundred sixty three
(Cable)No dangerous substances above the thresholds
Key orderOne million thirty one thousand two hundred sixty eight
(Measures)IP69K
Key sellingBF1CDA -
Packing unit1 pcs
ETIM 5.0 (eCl@ss)EC001855
China RoHS (Cable)Space of time for the intended use: unlimited = FEUP-e
Tariff number tariffEighty five million four hundred forty four thousand two hundred ninety
eCl@ss 8.0 (Ratings)Twenty seven million two hundred seventy nine thousand two hundred eighteen
eCl@ss 9.0 (Ratings)Twenty seven million sixty thousand three hundred eleven
Minimum order quantity50 pcs
(Environmental conditions)60 V DC
Material contact (Overview)CuSn
Material knurled (Overview)Stainless steel 1.4404
Name of standard (Material)Plug-in connector M12
Material body grip (Overview)TPU fire-retardant, self-extinguishing
Cable length (Data commercial)5 m
Index of protection (Measures)IP65
(Standards and specifications)-25 °C ... 80 °C (cable, available mobile)
Unit weight (excluding packaging)271,000 g
Encoding (Environmental conditions)A - standard
Material contact surface (Overview)Ni/Au
Standards/specifications (Material)IEC 61076-2-101
Room temperature (service) (Measures)-25 °C ... 90 °C (male / female)
Material support of contacts (Overview)TPU GF
Category surge (Environmental conditions)II
Cycles of plug (Environmental conditions)≥ 100
Tension sizing (Environmental conditions)48 V AC
Number of poles (Environmental conditions)Five
Pollution degree (Environmental conditions)Three
UL AWM Style (Standards and specifications)2464 / 1729 (80 °C/300 V)
Cabling total (Standards and specifications)5 drivers around padding as soul
Colors driver (Standards and specifications)Brown, white, blue, black, grey
Status indication (Environmental conditions)Not
Type of cable (Standards and specifications)Black PVC 5. Driver gray
Oil resistance (Standards and specifications)according to DIN en 60811-2-1, 168 h at 60 °C
Filling Material (Standards and specifications)Yarn of PP
Flame resistance (Standards and specifications)According to UL 758/1581 (Cable Flame)
Signal cable AWG (Standards and specifications)Twenty two
Insulation resistance (Environmental conditions)≥ 100 MΩ
Outer wrap, color (Standards and specifications)black RAL 9005
Section of driver (Standards and specifications)5x 0,34 mm2 (driver signals)
Test voltage Cable (Standards and specifications)≥ 3000 V AC
Conductive Material (Standards and specifications)Conductor Cu bare
Rated voltage Cable (Standards and specifications)≤ 300 V AC
Weight of the cable (Standards and specifications)52 kg/km
Class of flammability according to UL 94 (Material)HB
Class of flammability according to UL 94 (Overview)HB
Current sizing at 40 °C (Environmental conditions)4 To
Standards/specifications (Environmental conditions)Plug-in connector M12 to IEC 61076-2-101
Step of wiring total (Standards and specifications)60 mm
Abbreviation of cable (Standards and specifications)LiYY
Insulation resistance (Standards and specifications)≥ 100 MΩ*km (at 20 °C)
Outer casing, material (Standards and specifications)PVC
Cable type (abbreviation) (Standards and specifications)Five hundred fifteen
Outer diameter of cable D (Standards and specifications)To 5.9 mm ±0.15 mm
Room temperature (service) (Standards and specifications)-40 °C ... 80 °C (cable, fixed)
Resistance of the conductor (Standards and specifications)≤ 58 Ω/km (at 20 °C)
Thickness of wall Insulation (Standards and specifications)≥ 0.23 mm (Insulated conductor)
Material Insulation conductor (Standards and specifications)PVC
Protective circuit/component protection (Environmental conditions)without connect
Construction of the driver signal cable (Standards and specifications)42x 0.10 mm
Diameter of the conductors, insulation included (Standards and specifications)1,45 mm ±0.02 mm
Minimum bending radius, placed in a fixed manner (Standards and specifications)5 x D
Minimum bending radius, placed in a flexible way (Standards and specifications)10 x D

Product Description

Sensor/actuator cable, 5-pole, PVC, black RAL 9005, free cable end, to Elbowed Female M12, coding: A, cable length: 5 m
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Cable for sensors/actuators 5-pin, PVC, black RAL 9005, end of free cable, to connection socket angled M12, coded, cable length: 5 m

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top