Key Specifications
:DeviceNet™
Type:free cable end
Coding:A
Damping:≤ 22.9 dB/km (with 1 MHz)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
DeviceNet™
Typefree cable end
CodingA
Damping≤ 22.9 dB/km (with 1 MHz)
Shieldedyes
ShieldingTinned copper braided shield
Bus systemCANopen®/DeviceNet™
Cable typeCANopen®/DeviceNet™, PUR, black
ApplicationBus system
Coding typeA (Standard)
Sensor typeCANopen®
Acceleration3 m/s²
Cable length20 m
Cable weight90 kg/km
Halogen-freein accordance with DIN VDE 0472 part 815
Product typeData cable preassembled
UL AWM Style21198 (80°C/300 V)
Overall twist2 pairs around a drain wire in the center to the core
Seal materialNBR
Twisted pairs2 cores to the pair
Bending radius70 mm
Cable capacitynom. 40 nF/km (Data cable)
Status displayNo
Wave impedance120 Ω ±10 % (with 1 MHz)
AWG signal line24
Cable structure2xAWG24/19+2xAWG22/19
Loop resistance≤ 181.80 Ω/km (Data cable)
Traversing path4.5 m
Traversing rate3 m/s
AWG power supply22
Contact materialCuSn
Flame resistanceUL 1581, Sec. 1060 (FT-1)
Other resistanceLow adhesion
Conductor materialTin-plated Cu litz wires
Contact resistance≤ 5 mΩ
Nominal current IN4 A
Nominal voltage UN48 V AC
Single wire, colorred-black, blue-white
Degree of pollution3
Dimensional drawing
Number of positions5
Transmission mediumCopper
Degree of protectionIP65
No. of cable outlets1
Overvoltage categoryII
Signal type/categoryCANopen®
Insulation resistance≥ 100 MΩ
Material of grip bodyTPU, hardly inflammable, self-extinguishing
External sheath, colorblack RAL 9005
Nominal voltage, cable≤ 300 V (Peak value, not for high-power applications)
Outer sheath, materialPUR
Status display presentNo
Test voltage Core/Core2000 V (50 Hz, 1 min.)
Type of pair shieldingPlastic-coated aluminum foil, aluminum side outside
Conductor cross section2x 0.25 mm² (Data cable)
External cable diameter6.7 mm ±0.3 mm
Optical shield covering80 %
Contact carrier materialTPU GF
Contact surface materialNi/Au
Material wire insulationFoamed PE (Data cable)
Number of bending cycles5000000
Test voltage Core/Shield2000 V (50 Hz, 1 min.)
Cable type (abbreviation)921
Cable insulation resistance≥ 5 GΩ*km (Data cable)
Insertion/withdrawal cycles≥ 100
Material for screw connectionZinc die-cast, nickel-plated
Wire diameter incl. insulation1.95 mm ±0.05 mm (Data cable)
Ambient temperature (operation)≤ 70 °C (cable, drag chain applications)
Conductor structure signal line19x 0.13 mm
Conductor structure, voltage supply19x 0.15 mm
Flammability rating according to UL 94HB
Minimum bending radius, fixed installation5 x D
Minimum bending radius, flexible installation10 x D
Minimum bending radius, drag chain applications10 x D

Product Description

Bus system cable, CANopen®, DeviceNet™, 5-position, free cable end, on Socket straight M12, coding: A, cable length: 20 m
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top