| Parameter | Value |
|---|---|
| DeviceNet™ | |
| Type | free cable end |
| Coding | A |
| Damping | ≤ 22.9 dB/km (with 1 MHz) |
| Shielded | yes |
| Shielding | Tinned copper braided shield |
| Bus system | CANopen®/DeviceNet™ |
| Cable type | CANopen®/DeviceNet™, PUR, black |
| Application | Bus system |
| Coding type | A (Standard) |
| Sensor type | CANopen® |
| Acceleration | 3 m/s² |
| Cable length | 20 m |
| Cable weight | 90 kg/km |
| Halogen-free | in accordance with DIN VDE 0472 part 815 |
| Product type | Data cable preassembled |
| UL AWM Style | 21198 (80°C/300 V) |
| Overall twist | 2 pairs around a drain wire in the center to the core |
| Seal material | NBR |
| Twisted pairs | 2 cores to the pair |
| Bending radius | 70 mm |
| Cable capacity | nom. 40 nF/km (Data cable) |
| Status display | No |
| Wave impedance | 120 Ω ±10 % (with 1 MHz) |
| AWG signal line | 24 |
| Cable structure | 2xAWG24/19+2xAWG22/19 |
| Loop resistance | ≤ 181.80 Ω/km (Data cable) |
| Traversing path | 4.5 m |
| Traversing rate | 3 m/s |
| AWG power supply | 22 |
| Contact material | CuSn |
| Flame resistance | UL 1581, Sec. 1060 (FT-1) |
| Other resistance | Low adhesion |
| Conductor material | Tin-plated Cu litz wires |
| Contact resistance | ≤ 5 mΩ |
| Nominal current IN | 4 A |
| Nominal voltage UN | 48 V AC |
| Single wire, color | red-black, blue-white |
| Degree of pollution | 3 |
| Dimensional drawing | |
| Number of positions | 5 |
| Transmission medium | Copper |
| Degree of protection | IP65 |
| No. of cable outlets | 1 |
| Overvoltage category | II |
| Signal type/category | CANopen® |
| Insulation resistance | ≥ 100 MΩ |
| Material of grip body | TPU, hardly inflammable, self-extinguishing |
| External sheath, color | black RAL 9005 |
| Nominal voltage, cable | ≤ 300 V (Peak value, not for high-power applications) |
| Outer sheath, material | PUR |
| Status display present | No |
| Test voltage Core/Core | 2000 V (50 Hz, 1 min.) |
| Type of pair shielding | Plastic-coated aluminum foil, aluminum side outside |
| Conductor cross section | 2x 0.25 mm² (Data cable) |
| External cable diameter | 6.7 mm ±0.3 mm |
| Optical shield covering | 80 % |
| Contact carrier material | TPU GF |
| Contact surface material | Ni/Au |
| Material wire insulation | Foamed PE (Data cable) |
| Number of bending cycles | 5000000 |
| Test voltage Core/Shield | 2000 V (50 Hz, 1 min.) |
| Cable type (abbreviation) | 921 |
| Cable insulation resistance | ≥ 5 GΩ*km (Data cable) |
| Insertion/withdrawal cycles | ≥ 100 |
| Material for screw connection | Zinc die-cast, nickel-plated |
| Wire diameter incl. insulation | 1.95 mm ±0.05 mm (Data cable) |
| Ambient temperature (operation) | ≤ 70 °C (cable, drag chain applications) |
| Conductor structure signal line | 19x 0.13 mm |
| Conductor structure, voltage supply | 19x 0.15 mm |
| Flammability rating according to UL 94 | HB |
| Minimum bending radius, fixed installation | 5 x D |
| Minimum bending radius, flexible installation | 10 x D |
| Minimum bending radius, drag chain applications | 10 x D |
Technical specifications and performance data