ParameterValue
GTIN4046356895651
(Cable)No hazardous substances above threshold values
Orderkey1410367
Packing unit1
(Dimensions)IP68
ETIM 5.0 (eCl@ss)EC001855
ETIM 6.0 (eCl@ss)EC001855
ETIM 7.0 (eCl@ss)EC001855
China RoHS (Cable)Environmentally friendly use period: unlimited = EFUP-e
UNSPSC 13.2 (ETIM)31251501
Custom tariff number85444290
(Ambient conditions)60 V DC
Contact material (General)CuSn
Material, knurls (General)Zinc die-cast, nickel-plated
Sealing material (General)NBR
Coding (Ambient conditions)B - inverse
Torque (Ambient conditions)0.4 Nm (M12 connector)
(Standards and Regulations)-25 °C ... 80 °C (cable, flexible installation)
eCl@ss 5.1 (Classifications)27061800
eCl@ss 6.0 (Classifications)27279200
eCl@ss 7.0 (Classifications)27279218
eCl@ss 8.0 (Classifications)27279218
eCl@ss 9.0 (Classifications)27060311
Material of grip body (General)TPU, hardly inflammable, self-extinguishing
Standard designation (Material)M12 connector
Standards/regulations (Material)IEC 61076-2-101
Degree of protection (Dimensions)IP65
Contact carrier material (General)TPU GF
Contact surface material (General)Ni/Au
Rated voltage (Ambient conditions)48 V AC
Status display (Ambient conditions)No
Length of cable (Key Commercial Data)2 m
Cable type (Standards and Regulations)PUR, black, 5th conductor gray
Wire colors (Standards and Regulations)Brown, white, blue, black, gray
Acceleration (Standards and Regulations)10 m/s²
Cable weight (Standards and Regulations)35 kg/km
Degree of pollution (Ambient conditions)3
Halogen-free (Standards and Regulations)in accordance with DIN VDE 0472 part 815
Number of positions (Ambient conditions)5
UL AWM style (Standards and Regulations)20549 / 10493 (80°C/300 V)
Overall twist (Standards and Regulations)5 cores, twisted
Overvoltage category (Ambient conditions)II
Bending radius (Standards and Regulations)50 mm
Insulation resistance (Ambient conditions)≥ 100 MΩ
Standards/regulations (Ambient conditions)M12 connector IEC 61076-2-101
AWG signal line (Standards and Regulations)22
Rated current at 40°C (Ambient conditions)4 A
Traversing path (Standards and Regulations)10 m
Traversing rate (Standards and Regulations)3 m/s
Ambient temperature (operation) (Dimensions)-25 °C ... 90 °C (Plug / socket)
Flame resistance (Standards and Regulations)in accordance with DIN UL-Style 20549
Material, filler (Standards and Regulations)PP
Other resistance (Standards and Regulations)partly UV-resistant in accordance with DIN EN ISO 4892-2-A
Resistance to oil (Standards and Regulations)in accordance with DIN EN 60811-2-1
Cable abbreviation (Standards and Regulations)Li9Y11Y-HF
Conductor material (Standards and Regulations)Bare Cu litz wires
Special properties (Standards and Regulations)Flexible cable conduit capable
Test voltage, cable (Standards and Regulations)≥ 3000 V
Conductor resistance (Standards and Regulations)≤ 58 Ω/km
Flammability rating according to UL 94 (General)HB
Insertion/withdrawal cycles (Ambient conditions)≥ 100
Flammability rating according to UL 94 (Material)HB
Thickness, insulation (Standards and Regulations)≥ 0.21 mm
External sheath, color (Standards and Regulations)black-gray RAL 7021
Nominal voltage, cable (Standards and Regulations)≤ 300 V
Outer sheath thickness (Standards and Regulations)approx. 0.7 mm
Outer sheath, material (Standards and Regulations)PUR
Conductor cross section (Standards and Regulations)5x 0.34 mm²
Number of bending cycles (Standards and Regulations)4000000
Cable type (abbreviation) (Standards and Regulations)115
External cable diameter D (Standards and Regulations)5 mm ±0.15 mm
Material conductor insulation (Standards and Regulations)PP
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 80 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations)42x 0.10 mm
Core diameter including insulation (Standards and Regulations)1.27 mm ±0.02 mm
Stripping length of the free conductor end (Key Commercial Data)50 mm
Minimum bending radius, fixed installation (Standards and Regulations)5 x D
Minimum bending radius, flexible installation (Standards and Regulations)10 x D

Product Description

Sensor/actuator cable, 5-pole, halogen-free PUR, greyish black RAL 7021, free cable end, to Straight connection female M12 SPEEDCON, coding: B, cable length: 2 m
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Sensor/actuator cable, 5-position, PUR halogen-free, black-gray RAL 7021, free cable end, on Socket straight M12 SPEEDCON, B-coded, cable length: 2 m

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top