| Parameter | Value |
|---|---|
| GTIN | 4046356637473 |
| (Cable) | No hazardous substances above threshold values |
| Orderkey | 1402958 |
| Packing unit | 1 |
| (Dimensions) | DeviceNet™ |
| UNSPSC 11 (ETIM) | 26121604 |
| ETIM 4.0 (eCl@ss) | EC001855 |
| ETIM 5.0 (eCl@ss) | EC001855 |
| ETIM 6.0 (eCl@ss) | EC001855 |
| ETIM 7.0 (eCl@ss) | EC001855 |
| China RoHS (Cable) | Environmentally friendly use period: unlimited = EFUP-e |
| UNSPSC 13.2 (ETIM) | 31251501 |
| UNSPSC 6.01 (ETIM) | 26121616 |
| Coding (Dimensions) | A - standard |
| UNSPSC 12.01 (ETIM) | 31251501 |
| Custom tariff number | 85444290 |
| UNSPSC 7.0901 (ETIM) | 26121616 |
| Contact material (General) | CuSn |
| Material, knurls (General) | Stainless steel |
| Rated voltage (Dimensions) | 48 V AC |
| Sealing material (General) | NBR |
| (Standards and Regulations) | ≤ 4000 pF (Signal line, Core-Shield) |
| eCl@ss 4.0 (Classifications) | 27060306 |
| eCl@ss 4.1 (Classifications) | 27060306 |
| eCl@ss 5.0 (Classifications) | 27061801 |
| eCl@ss 5.1 (Classifications) | 27061800 |
| eCl@ss 6.0 (Classifications) | 27279200 |
| eCl@ss 7.0 (Classifications) | 27279218 |
| eCl@ss 8.0 (Classifications) | 27279218 |
| eCl@ss 9.0 (Classifications) | 27060311 |
| Material of grip body (General) | TPU, hardly inflammable, self-extinguishing |
| Degree of pollution (Dimensions) | 3 |
| Number of positions (Dimensions) | 5 |
| Overvoltage category (Dimensions) | II |
| Signal type/category (Dimensions) | CANopen® |
| Contact carrier material (General) | TPU GF |
| Contact surface material (General) | Ni/Au |
| Insulation resistance (Dimensions) | ≥ 100 MΩ |
| Rated current at 40°C (Dimensions) | 4 A |
| Length of cable (Key Commercial Data) | 10 m |
| Shielding (Standards and Regulations) | Tinned copper braided shield |
| Cable type (Standards and Regulations) | DeviceNet™ |
| Wire colors (Standards and Regulations) | Red-black, blue-white |
| Cable weight (Standards and Regulations) | 83 kg/km |
| Insertion/withdrawal cycles (Dimensions) | ≥ 100 |
| UL AWM style (Standards and Regulations) | 2464 (80°C/300 V) |
| Overall twist (Standards and Regulations) | 2 pairs with filler elements, around a drain wire in the center to the core |
| Twisted pairs (Standards and Regulations) | 2 cores to the pair |
| Signal runtime (Standards and Regulations) | 4.46 ns/m |
| Wave impedance (Standards and Regulations) | 120 Ω ±12 Ω (f = 1 MHz) |
| AWG signal line (Standards and Regulations) | 22 |
| AWG power supply (Standards and Regulations) | 22 |
| Flame resistance (Standards and Regulations) | in acc. with UL 1581, section 1061 |
| Conductor material (Standards and Regulations) | Tin-plated Cu litz wires |
| Test voltage, cable (Standards and Regulations) | 2000 V (50 Hz, 1 min.) |
| Working capacitance (Standards and Regulations) | approx. 39.8 nF (Signal line, Core-Core) |
| Conductor resistance (Standards and Regulations) | ≤ 56 Ω/km |
| Flammability rating according to UL 94 (General) | HB |
| Flammability rating according to UL 94 (Material) | HB |
| Insulation resistance (Standards and Regulations) | ≥ 20 MΩ*km |
| Thickness, insulation (Standards and Regulations) | ≥ 0.3 mm (Wire insulation power supply) |
| External sheath, color (Standards and Regulations) | black |
| Nominal voltage, cable (Standards and Regulations) | ≤ 300 V |
| Outer sheath thickness (Standards and Regulations) | ≥ 1 mm |
| Outer sheath, material (Standards and Regulations) | PVC |
| Type of pair shielding (Standards and Regulations) | Aluminum-lined polyester foil |
| Conductor cross section (Standards and Regulations) | 2x 0.34 mm² (Signal line) |
| Optical shield covering (Standards and Regulations) | 85 % |
| Cable type (abbreviation) (Standards and Regulations) | 927 |
| External cable diameter D (Standards and Regulations) | 8.3 mm ±0,3 mm |
| Material conductor insulation (Standards and Regulations) | Foamed PP (Signal line) |
| Ambient temperature (operation) (Standards and Regulations) | -30 °C ... 80 °C |
| Conductor structure signal line (Standards and Regulations) | 44x 0.10 mm |
| Core diameter including insulation (Standards and Regulations) | 2.55 mm (Signal line) |
| Conductor structure, voltage supply (Standards and Regulations) | 44x 0.10 mm |
| Minimum bending radius, fixed installation (Standards and Regulations) | 4 x D |
| Minimum bending radius, flexible installation (Standards and Regulations) | 8 x D |