Service time: Monday to Friday 9:00-18:00
SAC-5P-10,0-927/M12FS VA - SAC-5P-10,0-927/M12FS VA 1402958 PHOENIX CONTACT Bus system cable SAC-5P-10,0-927/M12FS VA 1402958
In Stock Hot Product

SAC-5P-10,0-927/M12FS VA

SAC-5P-10,0-927/M12FS VA 1402958 PHOENIX CONTACT Bus system cable SAC-5P-10,0-927/M12FS VA 1402958

$0.00USD
4398 in stock
Key Specifications
GTIN:4046356637473
(Cable):No hazardous substances above threshold values
Orderkey:1402958
Packing unit:1
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356637473
(Cable)No hazardous substances above threshold values
Orderkey1402958
Packing unit1
(Dimensions)DeviceNet™
UNSPSC 11 (ETIM)26121604
ETIM 4.0 (eCl@ss)EC001855
ETIM 5.0 (eCl@ss)EC001855
ETIM 6.0 (eCl@ss)EC001855
ETIM 7.0 (eCl@ss)EC001855
China RoHS (Cable)Environmentally friendly use period: unlimited = EFUP-e
UNSPSC 13.2 (ETIM)31251501
UNSPSC 6.01 (ETIM)26121616
Coding (Dimensions)A - standard
UNSPSC 12.01 (ETIM)31251501
Custom tariff number85444290
UNSPSC 7.0901 (ETIM)26121616
Contact material (General)CuSn
Material, knurls (General)Stainless steel
Rated voltage (Dimensions)48 V AC
Sealing material (General)NBR
(Standards and Regulations)≤ 4000 pF (Signal line, Core-Shield)
eCl@ss 4.0 (Classifications)27060306
eCl@ss 4.1 (Classifications)27060306
eCl@ss 5.0 (Classifications)27061801
eCl@ss 5.1 (Classifications)27061800
eCl@ss 6.0 (Classifications)27279200
eCl@ss 7.0 (Classifications)27279218
eCl@ss 8.0 (Classifications)27279218
eCl@ss 9.0 (Classifications)27060311
Material of grip body (General)TPU, hardly inflammable, self-extinguishing
Degree of pollution (Dimensions)3
Number of positions (Dimensions)5
Overvoltage category (Dimensions)II
Signal type/category (Dimensions)CANopen®
Contact carrier material (General)TPU GF
Contact surface material (General)Ni/Au
Insulation resistance (Dimensions)≥ 100 MΩ
Rated current at 40°C (Dimensions)4 A
Length of cable (Key Commercial Data)10 m
Shielding (Standards and Regulations)Tinned copper braided shield
Cable type (Standards and Regulations)DeviceNet™
Wire colors (Standards and Regulations)Red-black, blue-white
Cable weight (Standards and Regulations)83 kg/km
Insertion/withdrawal cycles (Dimensions)≥ 100
UL AWM style (Standards and Regulations)2464 (80°C/300 V)
Overall twist (Standards and Regulations)2 pairs with filler elements, around a drain wire in the center to the core
Twisted pairs (Standards and Regulations)2 cores to the pair
Signal runtime (Standards and Regulations)4.46 ns/m
Wave impedance (Standards and Regulations)120 Ω ±12 Ω (f = 1 MHz)
AWG signal line (Standards and Regulations)22
AWG power supply (Standards and Regulations)22
Flame resistance (Standards and Regulations)in acc. with UL 1581, section 1061
Conductor material (Standards and Regulations)Tin-plated Cu litz wires
Test voltage, cable (Standards and Regulations)2000 V (50 Hz, 1 min.)
Working capacitance (Standards and Regulations)approx. 39.8 nF (Signal line, Core-Core)
Conductor resistance (Standards and Regulations)≤ 56 Ω/km
Flammability rating according to UL 94 (General)HB
Flammability rating according to UL 94 (Material)HB
Insulation resistance (Standards and Regulations)≥ 20 MΩ*km
Thickness, insulation (Standards and Regulations)≥ 0.3 mm (Wire insulation power supply)
External sheath, color (Standards and Regulations)black
Nominal voltage, cable (Standards and Regulations)≤ 300 V
Outer sheath thickness (Standards and Regulations)≥ 1 mm
Outer sheath, material (Standards and Regulations)PVC
Type of pair shielding (Standards and Regulations)Aluminum-lined polyester foil
Conductor cross section (Standards and Regulations)2x 0.34 mm² (Signal line)
Optical shield covering (Standards and Regulations)85 %
Cable type (abbreviation) (Standards and Regulations)927
External cable diameter D (Standards and Regulations)8.3 mm ±0,3 mm
Material conductor insulation (Standards and Regulations)Foamed PP (Signal line)
Ambient temperature (operation) (Standards and Regulations)-30 °C ... 80 °C
Conductor structure signal line (Standards and Regulations)44x 0.10 mm
Core diameter including insulation (Standards and Regulations)2.55 mm (Signal line)
Conductor structure, voltage supply (Standards and Regulations)44x 0.10 mm
Minimum bending radius, fixed installation (Standards and Regulations)4 x D
Minimum bending radius, flexible installation (Standards and Regulations)8 x D

Product Description

Bus System Cable, CANopen®, DeviceNet™, 5-pole, shielded, free cable end, to Straight female M12, encoding: A, cable length: 10 m
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Bus system cable, CANopen®, DeviceNet™, 5-position, PVC, black, shielded, free cable end, on Socket straight M12, A-coded, cable length: 10 m

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top