| Parameter | Value |
|---|---|
| Silicone-free | |
| Note | Due to the extremely robust outer sheath, this cable should only be stripped in 5 cm increments. |
| Type | free cable end |
| Coding | A |
| Shielded | no |
| Cable type | Gray, highly flexible PUR |
| Coding type | A |
| Acceleration | 5 m/s² |
| Cable length | 10 m |
| Cable weight | 38 kg/km |
| Halogen-free | in accordance with DIN VDE 0472 part 815 |
| Product type | Sensor/actuator cable |
| Short symbol | LiF9Y11Y |
| UL AWM Style | 20549 |
| Overall twist | 5 wires around filler to the core |
| Torsion force | ± 360 °/m |
| Status display | No |
| Torsion cycles | 1000000 |
| AWG signal line | 22 |
| Traversing path | 5 m |
| Traversing rate | 3.3 m/s |
| Cable resistance | approx. 53 Ω/km |
| Flame resistance | in accordance with UL 758/1581 FT2 |
| Material, filler | PE |
| Other resistance | Highly resistant to acids, alkaline solutions and solvents |
| Resistance to oil | in accordance with DIN EN 60811-2-1 |
| Conductor material | Bare Cu litz wires |
| Contact resistance | ≤ 5 mΩ |
| Nominal current IN | 4 A |
| Nominal voltage UN | 60 V |
| Single wire, color | black, brown,blue, white, gray |
| Special properties | Cable jacket is welding spark-resistant, recyclable, matt, low-adhesion, abrasion-resistant, flame-retardant, and self-extinguishing |
| Degree of pollution | 3 |
| Dimensional drawing | |
| Number of positions | 5 |
| Test voltage, cable | 2000 V |
| Degree of protection | IP65 |
| No. of cable outlets | 1 |
| Overvoltage category | II |
| Insulation resistance | ≥ 100 MΩ |
| External sheath, color | gray RAL 7001 |
| Nominal voltage, cable | 300 V |
| Outer sheath, material | PUR |
| Status display present | No |
| Conductor cross section | 5x 0.34 mm² (Signal line) |
| External cable diameter | 5.1 mm ±0.2 mm |
| Material wire insulation | PP |
| Number of bending cycles | 10000000 |
| Cable type (abbreviation) | 800 |
| Cable insulation resistance | ≥ 20 MΩ*km |
| Insertion/withdrawal cycles | ≥ 100 |
| Wire diameter incl. insulation | 1.3 mm ±0.05 mm (Signal line) |
| Ambient temperature (operation) | -25 °C ... 80 °C (Cable, flexible installation) |
| Conductor structure signal line | 42x 0.10 mm |
| Flammability rating according to UL 94 | HB |
| Minimum bending radius, fixed installation | 4 x D |
| Minimum bending radius, flexible installation | 7.5 x D |
| Minimum bending radius, drag chain applications | 7,5 x D |
Technical specifications and performance data