Service time: Monday to Friday 9:00-18:00
SAC-5P-10,0-28X/M12FS OD - SAC-5P-10,0-28X/M12FS OD 1407260 PHOENIX CONTACT Sensor/actuator cable
In Stock Hot Product

SAC-5P-10,0-28X/M12FS OD

SAC-5P-10,0-28X/M12FS OD 1407260 PHOENIX CONTACT Sensor/actuator cable

$0.00USD
4217 in stock
Key Specifications
GTIN:4046356773775
Note:Made to Order (non-returnable)
(Cable):No hazardous substances above threshold values
Orderkey:1407260
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356773775
NoteMade to Order (non-returnable)
(Cable)No hazardous substances above threshold values
Orderkey1407260
Catalog pagePage 155 (C-4-2013)
Packing unit1 pc
(Dimensions)IP69K
Country of originPL (Poland)
China RoHS (Cable)Environmentally friendly use period: unlimited = EFUP-e
Custom tariff number85444290
(Ambient conditions)60 V DC
Contact material (General)CuSn
Material, knurls (General)Stainless steel
Sealing material (General)FPM
Coding (Ambient conditions)A - standard
Torque (Ambient conditions)0.4 Nm (M12 connector)
(Standards and Regulations)20 °C ±5 °C (cable, drag chain applications)
Material of grip body (General)PP
Standard designation (Material)M12 connector
Standards/regulations (Material)IEC 61076-2-101
Degree of protection (Dimensions)IP65
Contact carrier material (General)PP
Contact surface material (General)Ni/Au
Rated voltage (Ambient conditions)48 V AC
Status display (Ambient conditions)No
Weight per Piece (excluding packing)678.500 g
Length of cable (Key Commercial Data)10 m
Cable type (Standards and Regulations)PE-X black
Wire colors (Standards and Regulations)Brown, white, blue, black, gray
Acceleration (Standards and Regulations)10 m/s²
Cable weight (Standards and Regulations)70 kg/km
Degree of pollution (Ambient conditions)3
Halogen-free (Standards and Regulations)in accordance with DIN VDE 0472 part 815
Number of positions (Ambient conditions)5
Overall twist (Standards and Regulations)5 wires around filler to the core
Insulation resistance (Ambient conditions)≥ 100 MΩ
Standards/regulations (Ambient conditions)M12 connector IEC 61076-2-101
AWG signal line (Standards and Regulations)20
Rated current at 40°C (Ambient conditions)4 A
Traversing path (Standards and Regulations)10 m
Traversing rate (Standards and Regulations)3 m/s
Ambient temperature (operation) (Dimensions)-40 °C ... 105 °C (Plug / socket)
Flame resistance (Standards and Regulations)According to DIN EN 60332-1-2
Material, filler (Standards and Regulations)PP yarn
Other resistance (Standards and Regulations)Resistance to fuels according to IEC 60811, 168 h at 70°C
Resistance to oil (Standards and Regulations)According to DIN EN 60811-2-1, 168 h at 100°C
Cable abbreviation (Standards and Regulations)Li2X2X
Conductor material (Standards and Regulations)Bare Cu litz wires
Special properties (Standards and Regulations)Irradiated
Test voltage, cable (Standards and Regulations)≥ 3000 V AC (Spark test)
Conductor resistance (Standards and Regulations)≤ 39 Ω/m (at 20 °C)
Flammability rating according to UL 94 (General)V0
Insertion/withdrawal cycles (Ambient conditions)≥ 100
Flammability rating according to UL 94 (Material)V0
Insulation resistance (Standards and Regulations)≥ 100 MΩ*km (at 20 °C)
Protective circuit/component (Ambient conditions)unwired
Thickness, insulation (Standards and Regulations)approx. 0.3 mm (Core insulation)
External sheath, color (Standards and Regulations)black-gray RAL 7021
Nominal voltage, cable (Standards and Regulations)≤ 300 V AC
Outer sheath thickness (Standards and Regulations)approx. 1.25 mm
Outer sheath, material (Standards and Regulations)PE-X
Conductor cross section (Standards and Regulations)5x 0.5 mm²
Number of bending cycles (Standards and Regulations)2000000
Cable type (abbreviation) (Standards and Regulations)28X
External cable diameter D (Standards and Regulations)6.8 mm ±0.2 mm
Material conductor insulation (Standards and Regulations)PE-X
Length of twist, overall twist (Standards and Regulations)68 mm
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 105 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations)28x 0.15 mm
Core diameter including insulation (Standards and Regulations)1.6 mm ±0.5 mm
Minimum bending radius, fixed installation (Standards and Regulations)5 x D
Minimum bending radius, flexible installation (Standards and Regulations)10 x D
Minimum bending radius, drag chain applications (Standards and Regulations)10 x D

Product Description

Sensor/actuator cable, 5-pole, halogen-free PE-X, greyish black RAL 7021, free cable end, to straight connection female M12, coding: A, cable length: 10 m, for outdoor applications, with stainless ste
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top