Service time: Monday to Friday 9:00-18:00
SAC-5P- 0,75-28X/FS OD CH-AC - SAC-5P- 0,75-28X/FS OD CH-AC 1073775 PHOENIX CONTACT Sensor/actuator cable SAC-5P- 0,75-28X/FS OD CH-AC 1073..
In Stock Hot Product

SAC-5P- 0,75-28X/FS OD CH-AC

SAC-5P- 0,75-28X/FS OD CH-AC 1073775 PHOENIX CONTACT Sensor/actuator cable SAC-5P- 0,75-28X/FS OD CH-AC 1073..

$0.00USD
3842 in stock
Key Specifications
GTIN:4055626770147
Orderkey:1073775
Packing unit:1
(Dimensions):-40 °C ... 85 °C (On sudden changes in temperature (according to IEC 60512-11-4))
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626770147
Orderkey1073775
Packing unit1
(Dimensions)-40 °C ... 85 °C (On sudden changes in temperature (according to IEC 60512-11-4))
Custom tariff number85444290
(Ambient conditions)60 V DC
Contact material (General)CuSn
Material, knurls (General)Stainless steel
Sealing material (General)FPM
Coding (Ambient conditions)A - standard
(Standards and Regulations)20 °C ±5 °C (cable, drag chain applications)
Material of grip body (General)PP
Standard designation (Material)M12 connector
Standards/regulations (Material)IEC 61076-2-101
Contact carrier material (General)PP
Contact surface material (General)Ni/Au
Rated voltage (Ambient conditions)48 V AC
Status display (Ambient conditions)No
Length of cable (Key Commercial Data)0.75 m
Cable type (Standards and Regulations)PE-X black
Wire colors (Standards and Regulations)Brown, white, blue, black, gray
Acceleration (Standards and Regulations)10 m/s²
Cable weight (Standards and Regulations)70 kg/km
Degree of pollution (Ambient conditions)3
Halogen-free (Standards and Regulations)in accordance with DIN VDE 0472 part 815
Number of positions (Ambient conditions)5
Overall twist (Standards and Regulations)5 wires around filler to the core
Insulation resistance (Ambient conditions)≥ 100 MΩ
Standards/regulations (Ambient conditions)M12 connector IEC 61076-2-101
AWG signal line (Standards and Regulations)20
Rated current at 40°C (Ambient conditions)4 A
Traversing path (Standards and Regulations)10 m
Traversing rate (Standards and Regulations)3 m/s
Ambient temperature (operation) (Dimensions)-40 °C ... 105 °C (Plug / socket)
Flame resistance (Standards and Regulations)According to DIN EN 60332-1-2
Material, filler (Standards and Regulations)PP yarn
Other resistance (Standards and Regulations)Resistance to fuels according to IEC 60811, 168 h at 70°C
Resistance to oil (Standards and Regulations)According to DIN EN 60811-2-1, 168 h at 100°C
Cable abbreviation (Standards and Regulations)Li2X2X
Conductor material (Standards and Regulations)Bare Cu litz wires
Special properties (Standards and Regulations)Irradiated
Test voltage, cable (Standards and Regulations)≥ 3000 V AC (Spark test)
Conductor resistance (Standards and Regulations)≤ 39 Ω/m (at 20 °C)
Flammability rating according to UL 94 (General)V0
Insertion/withdrawal cycles (Ambient conditions)≥ 100
Flammability rating according to UL 94 (Material)V0
Insulation resistance (Standards and Regulations)≥ 100 MΩ*km (at 20 °C)
Protective circuit/component (Ambient conditions)unwired
Thickness, insulation (Standards and Regulations)approx. 0.3 mm (Core insulation)
External sheath, color (Standards and Regulations)black-gray RAL 7021
Nominal voltage, cable (Standards and Regulations)≤ 300 V AC
Outer sheath thickness (Standards and Regulations)approx. 1.25 mm
Outer sheath, material (Standards and Regulations)PE-X
Conductor cross section (Standards and Regulations)5x 0.5 mm²
Number of bending cycles (Standards and Regulations)2000000
Cable type (abbreviation) (Standards and Regulations)28X
External cable diameter D (Standards and Regulations)6.8 mm ±0.2 mm
Material conductor insulation (Standards and Regulations)PE-X
Length of twist, overall twist (Standards and Regulations)68 mm
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 105 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations)28x 0.15 mm
Core diameter including insulation (Standards and Regulations)1.6 mm ±0.5 mm
Minimum bending radius, fixed installation (Standards and Regulations)5 x D
Minimum bending radius, flexible installation (Standards and Regulations)10 x D
Minimum bending radius, drag chain applications (Standards and Regulations)10 x D

Product Description

Sensor/Actuator Cable, 5-Pole, Halogen-Free PE-X, Grey-Black RAL 7021, Free Cable End, to Straight Connecting Female M12, Coding: A, Cable Length: 0.75 m, For Outdoor Applications, With Stainless Stee
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Sensor/actuator cable, 5-position, PE-X halogen-free, black-gray RAL 7021, free cable end, on Socket straight M12, A-coded, cable length: 0.75 m, for outdoor applications, with high-grade steel knurl

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top