| Parameter | Value |
|---|---|
| 60 V DC | |
| Type | Plug straight M12 Push Pull |
| Coding | A |
| Shielded | yes |
| Cable type | PUR halogen-free black [PUR] |
| Application | Standard |
| Coding type | A |
| Cable length | 3 m |
| Cable weight | 36 kg/km |
| Halogen-free | in accordance with DIN VDE 0472 part 815 |
| Locking type | Push Pull |
| Product type | Sensor/actuator cable |
| Test voltage | ≥ 3000 V |
| UL AWM Style | 20549 / 10493 (80°C/300 V) |
| Overall twist | 4 wires, twisted |
| Cable capacity | ≤ 80 pF/m (Conductor-Conductor) |
| Status display | No |
| Wave impedance | ≥ 62 Ω (f = 10 MHz) |
| AWG signal line | 22 |
| Flame resistance | in accordance with UL 758/1581 FT2 |
| Other resistance | Highly resistant to acids, alkaline solutions and solvents |
| Connection method | Push-Pull |
| Resistance to oil | in accordance with DIN EN 60811-2-1 |
| Conductor material | Bare Cu litz wires |
| Contact resistance | ≤ 5 mΩ |
| Nominal current IN | 4 A |
| Nominal voltage UN | 48 V AC |
| Protective circuit | unwired |
| Single wire, color | brown, white, blue, black |
| Special properties | Flexible cable conduit capable |
| Degree of pollution | 3 |
| Dimensional drawing | |
| Max. bending cycles | 10000000 |
| Number of positions | 4 |
| Degree of protection | IP65 |
| No. of cable outlets | 1 |
| Overvoltage category | II |
| Standard designation | M12-Push-Pull |
| Insulation resistance | ≥ 100 MΩ |
| Thickness, insulation | ≥ 0.21 mm |
| External sheath, color | black-gray RAL 7021 |
| Nominal voltage, cable | ≤ 300 V |
| Outer sheath, material | PUR |
| Status display present | No |
| Conductor cross section | 4x 0.34 mm² (Signal line) |
| External cable diameter | 4.95 mm ±0.2 mm |
| Optical shield covering | 80 % |
| Thickness, outer sheath | approx. 0.5 mm |
| Material wire insulation | PP |
| Standards/specifications | IEC 61076-2-010 |
| Max. conductor resistance | 58 Ω/km |
| Insertion/withdrawal cycles | ≥ 100 |
| Wire diameter incl. insulation | 1.27 mm ±0.02 mm (Signal line) |
| Ambient temperature (operation) | -40 °C ... 80 °C (cable, fixed installation) |
| Conductor structure signal line | 42x 0.10 mm |
| Flammability rating according to UL 94 | V0 |
| Minimum bending radius, fixed installation | 5 x D |
| Smallest bending radius, fixed installation | 25 mm |
| Minimum bending radius, flexible installation | 10 x D |
| Smallest bending radius, movable installation | 50 mm |
Technical specifications and performance data