| Parameter | Value |
|---|---|
| GTIN | 4055626353210 |
| (Cable) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Orderkey | 1423669 |
| Packing unit | 1 |
| (Dimensions) | IP67 |
| China RoHS (Cable) | Environmentally Friendly Use Period = 50 |
| REACh SVHC (Cable) | Lead 7439-92-1 |
| Custom tariff number | 85444290 |
| Contact material (General) | CuZn |
| Material, knurls (General) | Zinc die-cast, nickel-plated |
| Coding (Ambient conditions) | S power |
| Torque (Ambient conditions) | 0.4 Nm (M12 connector) |
| (Standards and Regulations) | -30 °C ... 90 °C (cable, flexible installation) |
| Material of grip body (General) | PA |
| Standard designation (Material) | M12 connector |
| Standards/regulations (Material) | IEC 61076-2-111 |
| Degree of protection (Dimensions) | IP65 |
| Contact carrier material (General) | PA |
| Contact surface material (General) | Ni/Au |
| Rated voltage (Ambient conditions) | 690 V AC |
| Status display (Ambient conditions) | No |
| Length of cable (Key Commercial Data) | 12.5 m |
| Shielding (Standards and Regulations) | Tinned copper-braided shield, approx. 85% covering |
| Cable type (Standards and Regulations) | PUR halogen-free orange shielded |
| Color handle area (Ambient conditions) | black |
| Wire colors (Standards and Regulations) | Black 1, black 2, black 3, green/yellow |
| Acceleration (Standards and Regulations) | 10 m/s² |
| Degree of pollution (Ambient conditions) | 3 |
| Halogen-free (Standards and Regulations) | according to VDE 0282-13 Appendix C |
| Number of positions (Ambient conditions) | 4 |
| UL AWM style (Standards and Regulations) | 20234 / 10492 (80°C/1000 V) |
| Overall twist (Standards and Regulations) | 4 wires optimally twisted |
| Overvoltage category (Ambient conditions) | III |
| Torsion force (Standards and Regulations) | ± 25 °/m |
| Insulation resistance (Ambient conditions) | ≥ 100 MΩ |
| Standards/regulations (Ambient conditions) | M12 connector IEC 61076-2-111 |
| Rated current at 40°C (Ambient conditions) | 12 A |
| Traversing path (Standards and Regulations) | 10 m |
| Traversing rate (Standards and Regulations) | 3 m/s |
| AWG power supply (Standards and Regulations) | 16 |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 85 °C (Plug / socket) |
| Flame resistance (Standards and Regulations) | according to EN 60332-1-2 |
| Other resistance (Standards and Regulations) | UV resistant |
| Resistance to oil (Standards and Regulations) | in accordance with DIN EN 60811-2-1 |
| Cable abbreviation (Standards and Regulations) | 9YSLC11Y-JZ |
| Conductor material (Standards and Regulations) | Bare Cu litz wires |
| Test voltage, cable (Standards and Regulations) | 4260 V AC (5 min.) |
| Conductor resistance (Standards and Regulations) | ≤ 13.3 Ω/km (at 20 °C) |
| Flammability rating according to UL 94 (General) | V0 |
| Insertion/withdrawal cycles (Ambient conditions) | > 100 |
| Flammability rating according to UL 94 (Material) | V0 |
| Insulation resistance (Standards and Regulations) | ≥ 10 MΩ*km (at 20 °C) |
| Protective circuit/component (Ambient conditions) | unwired |
| Thickness, insulation (Standards and Regulations) | 0.4 mm |
| External sheath, color (Standards and Regulations) | orange RAL 2003 |
| Nominal voltage, cable (Standards and Regulations) | 1000 V AC |
| Outer sheath thickness (Standards and Regulations) | 1.2 mm |
| Outer sheath, material (Standards and Regulations) | PUR |
| Conductor cross section (Standards and Regulations) | 4x 1.5 mm² |
| Number of bending cycles (Standards and Regulations) | 4000000 |
| Cable type (abbreviation) (Standards and Regulations) | PUR |
| External cable diameter D (Standards and Regulations) | 9.7 mm ±0,3 mm |
| Material conductor insulation (Standards and Regulations) | PP |
| Ambient temperature (operation) (Standards and Regulations) | -40 °C ... 90 °C (cable, fixed installation) |
| Core diameter including insulation (Standards and Regulations) | ≤ 2.5 mm |
| Conductor structure, voltage supply (Standards and Regulations) | 78x 0.15 mm |
| Minimum bending radius, fixed installation (Standards and Regulations) | 5 x D |
| Minimum bending radius, flexible installation (Standards and Regulations) | 7.5 x D |
| Minimum bending radius, drag chain applications (Standards and Regulations) | 10 x D |
Technical specifications and performance data