Service time: Monday to Friday 9:00-18:00
SAC-4P-MS/ 5,0-28R/MS SCO RAIL - SAC-4P-MS/ 5,0-28R/MS SCO RAIL 1420330 PHOENIX CONTACT Cable for sensors/actuators SAC-4P-MS/ 5,0-28R/MS SCO..
In Stock Hot Product

SAC-4P-MS/ 5,0-28R/MS SCO RAIL

SAC-4P-MS/ 5,0-28R/MS SCO RAIL 1420330 PHOENIX CONTACT Cable for sensors/actuators SAC-4P-MS/ 5,0-28R/MS SCO..

$0.00USD
3201 in stock
Key Specifications
EAN:Four trillion fifty five billion six hundred twenty six million two hundred five thousand eight hundred ninety two
Key order:One million four hundred twenty thousand three hundred thirty
(Measures):Shocks, vibrations 50155
Key selling:BF1CCA -
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
EANFour trillion fifty five billion six hundred twenty six million two hundred five thousand eight hundred ninety two
Key orderOne million four hundred twenty thousand three hundred thirty
(Measures)Shocks, vibrations 50155
Key sellingBF1CCA -
Packing unit1 pcs
ETIM 5.0 (eCl@ss)EC001855
ETIM 6.0 (eCl@ss)EC001855
ETIM 7.0 (eCl@ss)EC001855
Encoding (Measures)A - standard
Tariff number tariffEighty five million four hundred forty four thousand two hundred ninety
eCl@ss 6.0 (Ratings)Twenty seven million two hundred seventy nine thousand two hundred
eCl@ss 7.0 (Ratings)Twenty seven million two hundred seventy nine thousand two hundred eighteen
eCl@ss 9.0 (Ratings)Twenty seven million sixty thousand three hundred eleven
Category surge (Measures)II
Cycles of plug (Measures)≥ 100
Tension sizing (Measures)48 V AC
Number of poles (Measures)Four
Material contact (Overview)CuSn
Material knurled (Overview)Die-cast zinc, nickel plated
Name of standard (Material)Shock, vibration
Pollution degree (Measures)Three
Status indication (Measures)Not
Material body grip (Overview)PA 6.6
Cable length (Data commercial)5 m
(Standards and specifications)-25 °C ... 90 °C (cable, available mobile)
Standards/provisions (Overview)PA 6.6: fire Protection in vehicles on rails - one set of requirements R22, R23 and R24 according to DIN en 45545-2 (hazard Level HL1 - HL3)
Insulation resistance (Measures)≥ 100 MΩ
Material of the board (Overview)NBR
Unit weight (excluding packaging)300,200 g
Current sizing at 40 °C (Measures)4 To
Material contact surface (Overview)Ni/Au
Standards/specifications (Material)IN 50155
Standards/specifications (Measures)Plug-in connector M12 to IEC 61076-2-101
Material support of contacts (Overview)PA 6.6
Shielding (Standards and specifications)Mesh of copper wires tinned
Cabling total (Standards and specifications)4-conductor longitudinally twisted
Colors driver (Standards and specifications)white 1, white 2, white 3, white 4
Type of cable (Standards and specifications)RADOX®black, shielded
Oil resistance (Standards and specifications)according to IRM-902, 72 hrs at 100 °C
Other resistors (Standards and specifications)resistant against fuels, according to IRM 903, 168 h at 70 °C
Flame resistance (Standards and specifications)IN 60332-1-2
Signal cable AWG (Standards and specifications)Twenty
Outer wrap, color (Standards and specifications)black
Section of driver (Standards and specifications)4x 0.5 mm2
Absence of halogen (Standards and specifications)according to en 50267-2-1
Test voltage Cable (Standards and specifications)3500 V AC (50 Hz, 5 min)
Conductive Material (Standards and specifications)Conductor Cu tinned
Density of flue gas (Standards and specifications)BS 6853 D. 8.7
Protective circuit/component protection (Measures)without connect
Rated voltage Cable (Standards and specifications)600 V AC (Conductor-to-ground, OrZero)
Weight of the cable (Standards and specifications)56 kg/km
Class of flammability according to UL 94 (Material)V0
Class of flammability according to UL 94 (Overview)V0
Corrosion of gas fire (Standards and specifications)IN 50267-2-2
Outer casing, material (Standards and specifications)PE-X
Cable type (abbreviation) (Standards and specifications)28R
Outer diameter of cable D (Standards and specifications)5.4 mm ±0.3 mm
Room temperature (service) (Standards and specifications)-50 °C ... 120 °C (cable, fixed)
Resistance of the conductor (Standards and specifications)≤ 40,1 Ω/km
Material Insulation conductor (Standards and specifications)PE-X
Toxicity of gases from the fire (Standards and specifications)BS 6853 B. 1
Fire protection in vehicles on rails (Standards and specifications)BS 6853 (Category Ia, Ib, II)
Construction of the driver signal cable (Standards and specifications)19x 0.18 mm
Diameter of the conductors, insulation included (Standards and specifications)1.43 mm
Minimum bending radius, placed in a fixed manner (Standards and specifications)3 x D
Minimum bending radius, placed in a flexible way (Standards and specifications)4 x D

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Cable for sensors/actuators, 4-pole, PE-X halogen-free, black, shielded, cable length: 5 m, For railway applications

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top