Service time: Monday to Friday 9:00-18:00
SAC-4P-MS/2,55-240/FS SCO NLM - SAC-4P-MS/2,55-240/FS SCO NLM 1424273 PHOENIX CONTACT Sensor/actuator cable SAC-4P-MS/2,55-240/FS SCO NLM 14..
In Stock Hot Product

SAC-4P-MS/2,55-240/FS SCO NLM

SAC-4P-MS/2,55-240/FS SCO NLM 1424273 PHOENIX CONTACT Sensor/actuator cable SAC-4P-MS/2,55-240/FS SCO NLM 14..

$0.00USD
4842 in stock
Key Specifications
GTIN:4055626376349
(Cable):No hazardous substances above threshold values
Orderkey:1424273
Packing unit:1
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626376349
(Cable)No hazardous substances above threshold values
Orderkey1424273
Packing unit1
(Dimensions)IP67
ETIM 5.0 (eCl@ss)EC001855
ETIM 6.0 (eCl@ss)EC001855
ETIM 7.0 (eCl@ss)EC001855
China RoHS (Cable)Environmentally friendly use period: unlimited = EFUP-e
Custom tariff number85444290
(Ambient conditions)250 V DC
Contact material (General)CuSn
Material, knurls (General)Zinc die-cast, nickel-plated
Sealing material (General)NBR
Coding (Ambient conditions)A - standard
Torque (Ambient conditions)0.4 Nm
(Standards and Regulations)-25 °C ... 80 °C (cable, flexible installation)
eCl@ss 6.0 (Classifications)27279200
eCl@ss 7.0 (Classifications)27279218
eCl@ss 8.0 (Classifications)27279218
eCl@ss 9.0 (Classifications)27060311
Material of grip body (General)TPU, hardly inflammable, self-extinguishing
Standard designation (Material)M12 connector
Standards/regulations (Material)IEC 61076-2-101
Degree of protection (Dimensions)IP65
Contact carrier material (General)TPU GF
Contact surface material (General)Ni/Au
Rated voltage (Ambient conditions)250 V AC
Status display (Ambient conditions)No
Length of cable (Key Commercial Data)2.55 m
Cable type (Standards and Regulations)PUR halogen-free yellow
Wire colors (Standards and Regulations)brown, white, blue, black
Acceleration (Standards and Regulations)10 m/s²
Cable weight (Standards and Regulations)30 kg/km
Degree of pollution (Ambient conditions)3
Halogen-free (Standards and Regulations)in accordance with DIN VDE 0472 part 815
Number of positions (Ambient conditions)4
Overall twist (Standards and Regulations)4 wires, twisted
Overvoltage category (Ambient conditions)II
Bending radius (Standards and Regulations)47 mm
Insulation resistance (Ambient conditions)≥ 10 MΩ
Standards/regulations (Ambient conditions)M12 connector IEC 61076-2-101
AWG signal line (Standards and Regulations)22
Rated current at 40°C (Ambient conditions)4 A
Traversing path (Standards and Regulations)10 m
Traversing rate (Standards and Regulations)3 m/s
Ambient temperature (operation) (Dimensions)-25 °C ... 90 °C (Plug / socket)
Flame resistance (Standards and Regulations)in accordance with DIN UL-Style 20549
Other resistance (Standards and Regulations)Highly resistant to acids, alkaline solutions and solvents
Resistance to oil (Standards and Regulations)in accordance with DIN EN 60811-2-1
Cable abbreviation (Standards and Regulations)Li9Y11Y
Conductor material (Standards and Regulations)Bare Cu litz wires
Special properties (Standards and Regulations)Flexible cable conduit capable
Test voltage, cable (Standards and Regulations)≥ 3000 V
Conductor resistance (Standards and Regulations)max. 58 Ω/km (at 20 °C)
Flammability rating according to UL 94 (General)HB
Insertion/withdrawal cycles (Ambient conditions)≥ 100
Flammability rating according to UL 94 (Material)HB
Insulation resistance (Standards and Regulations)≥ 1 GΩ*km (at 20 °C)
Protective circuit/component (Ambient conditions)unwired
Thickness, insulation (Standards and Regulations)≥ 0.21 mm (Core insulation)
External sheath, color (Standards and Regulations)yellow
Nominal voltage, cable (Standards and Regulations)≤ 300 V
Outer sheath, material (Standards and Regulations)PUR
Conductor cross section (Standards and Regulations)4x 0.34 mm²
Number of bending cycles (Standards and Regulations)4000000
Cable type (abbreviation) (Standards and Regulations)240
External cable diameter D (Standards and Regulations)4.7 mm ±0.15 mm
Material conductor insulation (Standards and Regulations)PP
Length of twist, overall twist (Standards and Regulations)49.5 mm
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 80 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations)42x 0.10 mm
Core diameter including insulation (Standards and Regulations)1.27 mm ±0.02 mm
Smallest bending radius, fixed installation (Standards and Regulations)23.5 mm
Smallest bending radius, movable installation (Standards and Regulations)47 mm

Product Description

Sensor/actuator cable, 4-pole, halogen-free PUR, yellow, M12 SPEEDCON straight male connector, coding: A, to M12 SPEEDCON straight connection female, coding: A, cable length: 2.55 m, Customer variant
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Sensor/actuator cable, 4-position, PUR halogen-free, yellow, Plug straight M12 SPEEDCON, A-coded, on Socket straight M12 SPEEDCON, A-coded, cable length: 2.55 m, Customer version

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide