Service time: Monday to Friday 9:00-18:00
SAC-4P-MRDC2/ 5,0-936 SCO - SAC-4P-MRDC2/ 5,0-936 SCO 1410296 PHOENIX CONTACT Bus system cable, PROFINET, 4-pos., RADOX
In Stock Hot Product

SAC-4P-MRDC2/ 5,0-936 SCO

SAC-4P-MRDC2/ 5,0-936 SCO 1410296 PHOENIX CONTACT Bus system cable, PROFINET, 4-pos., RADOX

$0.00USD
4244 in stock
Key Specifications
GTIN:4046356895095
(Cable):For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey:1410296
(Drawings):
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356895095
(Cable)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey1410296
(Drawings)
Packing unit1 pc
(Dimensions)60 V DC
Country of originPL (Poland)
ETIM 4.0 (eCl@ss)EC000830
ETIM 5.0 (eCl@ss)EC001855
ETIM 6.0 (eCl@ss)EC001855
ETIM 7.0 (eCl@ss)EC001855
China RoHS (Cable)Environmentally Friendly Use Period = 50
REACh SVHC (Cable)
UNSPSC 13.2 (ETIM)31251501
UNSPSC 19.0 (ETIM)31251501
UNSPSC 20.0 (ETIM)31251501
UNSPSC 21.0 (ETIM)31251501
Coding (Dimensions)D - data
Custom tariff number85444290
Minimum order quantity50 pc
Contact material (General)CuSn
Length of cable (Drawings)5 m
Material, knurls (General)Zinc die-cast, nickel-plated
Rated voltage (Dimensions)48 V AC
Sealing material (General)NBR
(Standards and Regulations)-40 °C ... 90 °C (cable, flexible installation)
eCl@ss 4.0 (Classifications)27060300
eCl@ss 4.1 (Classifications)27060300
eCl@ss 5.0 (Classifications)27061800
eCl@ss 5.1 (Classifications)27061800
eCl@ss 6.0 (Classifications)27279200
eCl@ss 7.0 (Classifications)27279218
eCl@ss 8.0 (Classifications)27279218
eCl@ss 9.0 (Classifications)27060311
Material of grip body (General)TPU, hardly inflammable, self-extinguishing
Degree of pollution (Dimensions)3
Number of positions (Dimensions)4
Overvoltage category (Dimensions)II
Signal type/category (Dimensions)PROFINET
Contact carrier material (General)PA 6.6
Contact surface material (General)Ni/Au
Rated current at 40°C (Dimensions)4 A
Weight per Piece (excluding packing)0.000 g
Shielding (Standards and Regulations)Plastic-coated aluminum foil, tinned copper braided shield
Cable type (Standards and Regulations)Ethernet
Attenuation (Standards and Regulations)2 dB (with 1 MHz)
Return Loss (Standards and Regulations)35 dB (at 4 МHz)
Wire colors (Standards and Regulations)white-blue, orange-yellow
Cable weight (Standards and Regulations)81 g/m
Halogen-free (Standards and Regulations)According to EN 50267-2-1
Signal speed (Standards and Regulations)66 c
Fume toxicity (Standards and Regulations)BS 6853 B.1
Overall twist (Standards and Regulations)Star quad
Wave impedance (Standards and Regulations)100 Ω ±5 Ω (f = 100 MHz)
AWG signal line (Standards and Regulations)22
Cable structure (Standards and Regulations)1x4xAWG22/7; SF/TQ
Flame resistance (Standards and Regulations)EN 60332-1-2
Other resistance (Standards and Regulations)Resistance to fuels according to IRM 903, 168 h at 70 °C
Resistance to oil (Standards and Regulations)according to IRM 902, 72 h at 100 °C
Conductor material (Standards and Regulations)silver-plated Cu litz wires
Fume corrosiveness (Standards and Regulations)EN 50267-2-2
Shield attenuation (Standards and Regulations)40 dB (30 MHz ≤ f ≤ 100 MHz)
Coupling resistance (Standards and Regulations)200.00 mΩ/m (f ≤ 30 MHz)
Test voltage, cable (Standards and Regulations)2000 V AC (50 Hz, 5 minutes)
Working capacitance (Standards and Regulations)≤ 65 pF (core-core)
Conductor resistance (Standards and Regulations)≤ 54.4 Ω/km
Flammability rating according to UL 94 (General)V0
Flammability rating according to UL 94 (Material)V0
Concentration of fumes (Standards and Regulations)BS 6853 D.8.7
External sheath, color (Standards and Regulations)black RAL 9005
Nominal voltage, cable (Standards and Regulations)300 V AC
Outer sheath thickness (Standards and Regulations)≥ 0.8 mm
Outer sheath, material (Standards and Regulations)PE-X
Conductor cross section (Standards and Regulations)4x 0.34 mm²
Optical shield covering (Standards and Regulations)100 %
Cable type (abbreviation) (Standards and Regulations)936
External cable diameter D (Standards and Regulations)7.25 mm ±0,3 mm
Stripping length of the free conductor end (Drawings)50 mm
Material conductor insulation (Standards and Regulations)PE-X
Ambient temperature (operation) (Standards and Regulations)-50 °C ... 90 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations)7x 0.25 mm
Fire protection in rail vehicles (Standards and Regulations)BS 6853 (Category Ia, Ib, II)
Core diameter including insulation (Standards and Regulations)1.95 mm
Near end crosstalk attenuation (NEXT) (Standards and Regulations)80 dB (with 1 MHz)
Minimum bending radius, fixed installation (Standards and Regulations)6 x D
Minimum bending radius, flexible installation (Standards and Regulations)10 x D

Product Description

Cable for bus system, PROFINET, 4 poles, RADOX® GKW S, black RAL 9005, angled male connector M12 SPEEDCON, codif. D, to free cable end, cable length: 5 m, 270º coding
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Cable cross sectionPROFINET railway applications [936]

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top