Service time: Monday to Friday 9:00-18:00
SAC-4P-MRDC2/3,0-936 SCO - SAC-4P-MRDC2/3,0-936 SCO 1435849 PHOENIX CONTACT Cable, system bus, PROFINET, 4-pole, PE-X, black RAL 9005, ..
In Stock Hot Product

SAC-4P-MRDC2/3,0-936 SCO

SAC-4P-MRDC2/3,0-936 SCO 1435849 PHOENIX CONTACT Cable, system bus, PROFINET, 4-pole, PE-X, black RAL 9005, ..

$0.00USD
3700 in stock
Key Specifications
GTIN:Four trillion forty six billion three hundred fifty six million five hundred fifty four thousand eight hundred twenty four
(Size):IP68
(Cable):The information on hazardous substances found in the declaration of the manufacturer under "Downlaods"
Sales key:BF1CJN -
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTINFour trillion forty six billion three hundred fifty six million five hundred fifty four thousand eight hundred twenty four
(Size)IP68
(Cable)The information on hazardous substances found in the declaration of the manufacturer under "Downlaods"
Sales keyBF1CJN -
Pieces/pack.1 PCS
UNSPSC 11 (ETIM)Thirty one million two hundred fifty one thousand five hundred one
ETIM 3.0 (eCl@ss)EC001855
ETIM 4.0 (eCl@ss)EC001855
ETIM 5.0 (eCl@ss)EC001855
ETIM 6.0 (eCl@ss)EC001855
ETIM 7.0 (eCl@ss)EC001855
China RoHS (Cable)Period of use conforms to the target without damage to the environment (EFUP): 50 years
REACh SVHC (Cable)
UNSPSC 13.2 (ETIM)Thirty one million two hundred fifty one thousand five hundred one
UNSPSC 6.01 (ETIM)Thirty one million two hundred fifty one thousand five hundred one
UNSPSC 12.01 (ETIM)Thirty one million two hundred fifty one thousand five hundred one
UNSPSC 7.0901 (ETIM)Thirty one million two hundred fifty one thousand five hundred one
Number customs tariffEighty five million four hundred forty four thousand two hundred ninety
eCl@ss 4.0 (Rankings)Twenty seven million two hundred fifty thousand three hundred thirteen
eCl@ss 4.1 (Rankings)Twenty seven million two hundred fifty thousand three hundred thirteen
eCl@ss 5.0 (Rankings)Twenty seven million one hundred forty three thousand four hundred twenty three
eCl@ss 5.1 (Rankings)Twenty seven million one hundred forty three thousand four hundred
eCl@ss 6.0 (Rankings)Twenty seven million two hundred seventy nine thousand two hundred
eCl@ss 7.0 (Rankings)Twenty seven million two hundred seventy nine thousand two hundred eighteen
eCl@ss 8.0 (Rankings)Twenty seven million two hundred seventy nine thousand two hundred eighteen
eCl@ss 9.0 (Rankings)Twenty seven million sixty thousand three hundred eleven
Nut material (General)Zinc die-cast, nickel-plated
The code for the orderOne million four hundred thirty five thousand eight hundred forty nine
Material gasket (General)NBR
Contact material (General)CuSn
Material handles (General)TPU, hardly inflammable, self-extinguishing
(Environmental conditions)60 V DC
Degree of protection (Size)IP65
(Regulations and requirements)-40 °C ... 90 °C (cable, mobile installation)
Insert material latch (General)PA 6.6
Length. cable (Commercial data)3 m
Encoding (Environmental conditions)D - Data
Material surface contacts (General)Ni/Au
Weight per piece (package included)223,000 g
N. of poles (Environmental conditions)Four
Capacity (Regulations and requirements)≤ 65 pF (wire-to-wire )
Shielding (Regulations and requirements)Aluminium film plastic-coated, braided copper wire tinned
Cable type (Regulations and requirements)Ethernet
Color wire (Regulations and requirements)white-blue-orange-yellow
Rating voltage (Environmental conditions)48 V AC
Attenuation (Regulations and requirements)2 dB (1 MHz)
Pollution degree (Environmental conditions)Three
Class behaviour according to UL 94 (General)V0
Class behaviour according to UL 94 (Material)V0
Lay the entire (Regulations and requirements)Sternvierer
Oil resistance (Regulations and requirements)according to IRM-902, 72 h, 100 °C
Signal line AWG (Regulations and requirements)Twenty two
Structure cable (Regulations and requirements)1x4xAWG22/7; SF/TQ
Flame resistance (Regulations and requirements)EN 60332-1-2
Overvoltage category (Environmental conditions)II
Signal type/category (Environmental conditions)PROFINET
Gas-tight, flared (Regulations and requirements)BS 6853 D. 8.7
Test voltage cable (Regulations and requirements)2000 V AC (50 Hz, 5 minutes)
Rated current at 40 ℃ (Environmental conditions)4 To
Resistance coupling (Regulations and requirements)200,00 mΩ/m (f ≤ 30 MHz)
Stripping length of the free end (Commercial data)50 mm
Cover screen optical (Regulations and requirements)100 %
The other resistance (Regulations and requirements)resistant against fuels, according to IRM 903, 168 h at 70 °C
Attenuation of return (Regulations and requirements)35 dB (4 MHz)
Attenuation shielding (Regulations and requirements)40 dB (30 MHz ≤ f ≤ 100 MHz)
Cable outer diameter D (Regulations and requirements)7,25 mm ±0.3 mm
External sheath, color (Regulations and requirements)black RAL 9005
Outer sheath, material (Regulations and requirements)PE-X
Rated voltage of cable (Regulations and requirements)300 V AC
Conductor cross section (Regulations and requirements)4x 0.34 mm2
The absence of halogens (Regulations and requirements)according to EN 50267-2-1
The conductive material (Regulations and requirements)Cu wire silver
The speed of the signal (Regulations and requirements)66 c
The weight of the cable (Regulations and requirements)81 g/m
Characteristic impedance (Regulations and requirements)100 Ω ±5 Ω (f = 100 MHz)
Material insulation wire (Regulations and requirements)PE-X
Toxicity flammable gases (Regulations and requirements)BS 6853 B. 1
Cable type (abbreviation) (Regulations and requirements)Nine hundred thirty six
Corrosivity gas, flammable (Regulations and requirements)EN 50267-2-2
Tree conductor signal line (Regulations and requirements)7x 0.25 mm
Bend radius, minimum, fixed (Regulations and requirements)6 x D
Wall thickness outer jacket (Regulations and requirements)≥ 0.8 mm
resistance of the conductor (Regulations and requirements)≤ Eur 54.4 Ω/km
Bend radius, minimum, flexible (Regulations and requirements)10 x D
Ambient temperature (operation) (Regulations and requirements)-50 °C ... 90 °C (cable, fixed installation)
Attenuation paradiafonica (NEXT) (Regulations and requirements)80 dB (with 1 MHz)
Fire protection in rail vehicles (Regulations and requirements)BS 6853 (Category Ia, Ib, II)
Wire diameter including insulation (Regulations and requirements)1,95 mm

Product Description

Bus system cable, PROFINET, 4-pole, M12 angled connector, coding: D SPEEDCON, to free cable end, cable length: 3 m, 270° coding
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Cable, system bus, PROFINET, 4-pin, PE-X without halogenated, RAL 9005 black, Male angled M12 SPEEDCON, D-coded, on the ends of conductor the free, cable length: 3 m, Encoding 270°

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top