Service time: Monday to Friday 9:00-18:00
SAC-4P-M12Y/28X-9XM12F OD RI - SAC-4P-M12Y/28X-9XM12F OD RI 1421454 PHOENIX CONTACT Sensor/actuator cable SAC-4P-M12Y/28X-9XM12F OD RI 1421..
In Stock Hot Product

SAC-4P-M12Y/28X-9XM12F OD RI

SAC-4P-M12Y/28X-9XM12F OD RI 1421454 PHOENIX CONTACT Sensor/actuator cable SAC-4P-M12Y/28X-9XM12F OD RI 1421..

$0.00USD
3048 in stock
Key Specifications
GTIN:4055626263922
Orderkey:1421454
Packing unit:1
ETIM 5.0 (eCl@ss):EC001855
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626263922
Orderkey1421454
Packing unit1
ETIM 5.0 (eCl@ss)EC001855
ETIM 6.0 (eCl@ss)EC001855
Custom tariff number85444290
(Ambient conditions)250 V DC
(Key Commercial Data)120 °C (at 48 h - see test report 19233)
Contact material (General)CuSn
Material, knurls (General)Stainless steel
Sealing material (General)FPM
Coding (Ambient conditions)A - standard
Torque (Ambient conditions)0.4 Nm (M12 connector)
(Standards and Regulations)-15 °C ... 105 °C (cable, flexible installation)
eCl@ss 6.0 (Classifications)27279200
eCl@ss 7.0 (Classifications)27279218
eCl@ss 9.0 (Classifications)27060311
Material of grip body (General)PP
Standard designation (Material)M12 connector
Standards/regulations (Material)IEC 61076-2-101
Contact carrier material (General)PP
Contact surface material (General)Ni/Au
Rated voltage (Ambient conditions)250 V AC
Status display (Ambient conditions)No
Cable type (Standards and Regulations)PE-X black
Wire colors (Standards and Regulations)brown, white, blue, black
Acceleration (Standards and Regulations)10 m/s²
Cable weight (Standards and Regulations)44 kg/km
Degree of pollution (Ambient conditions)3
Halogen-free (Standards and Regulations)in accordance with DIN VDE 0472 part 815
Number of positions (Ambient conditions)4
Overall twist (Standards and Regulations)4 wires, twisted
Bending radius (Standards and Regulations)52 mm
Insulation resistance (Ambient conditions)≥ 100 MΩ
Standards/regulations (Ambient conditions)M12 connector IEC 61076-2-101
AWG signal line (Standards and Regulations)20
Rated current at 40°C (Ambient conditions)4 A
Traversing path (Standards and Regulations)10 m
Traversing rate (Standards and Regulations)3 m/s
Flame resistance (Standards and Regulations)according to DIN 60332-1-2
Other resistance (Standards and Regulations)UV resistant according to DIN VDE 0276-605
Resistance to oil (Standards and Regulations)in accordance with DIN EN 60811-2-1
Cable abbreviation (Standards and Regulations)Li2X2X
Conductor material (Standards and Regulations)Bare Cu litz wires
Fume corrosiveness (Standards and Regulations)according to IEC 60754
Special properties (Standards and Regulations)Irradiated
Test voltage, cable (Standards and Regulations)≥ 3000 V AC
Conductor resistance (Standards and Regulations)≤ 39 Ω/km (at 20 °C)
Flammability rating according to UL 94 (General)V0
Insertion/withdrawal cycles (Ambient conditions)≥ 100
Flammability rating according to UL 94 (Material)V0
Insulation resistance (Standards and Regulations)≥ 100 MΩ*km (at 20 °C)
Protective circuit/component (Ambient conditions)unwired
Thickness, insulation (Standards and Regulations)approx. 0.3 mm (Core insulation)
Concentration of fumes (Standards and Regulations)according to DIN EN 61034
External sheath, color (Standards and Regulations)black-gray RAL 7021
Nominal voltage, cable (Standards and Regulations)≤ 300 V AC
Outer sheath, material (Standards and Regulations)PE-X
Conductor cross section (Standards and Regulations)4x 0.5 mm² (Signal line)
Number of bending cycles (Standards and Regulations)2000000
Ambient temperature (operation) (Key Commercial Data)-40 °C ... 105 °C (Plug / socket)
Cable type (abbreviation) (Standards and Regulations)28X
External cable diameter D (Standards and Regulations)5.2 mm ±0.2 mm
Material conductor insulation (Standards and Regulations)PE-X
Length of twist, overall twist (Standards and Regulations)61.6 mm
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 105 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations)28x 0.15 mm
Core diameter including insulation (Standards and Regulations)1.6 mm ±0.05 mm (Signal line)
Smallest bending radius, fixed installation (Standards and Regulations)26 mm
Smallest bending radius, movable installation (Standards and Regulations)52 mm

Product Description

Sensor/Actuator Cable, 4-Pole, Halogen-Free, PE-X, Grey-Black RAL 7021, M12 Straight Male Connector, A, A Encoding: A, A Straight Male M12, Coding: A, M12 Y-Distributor, Outdoor Application, with Stai
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Sensor/actuator cable, 4-position, PE-X halogen-free, black-gray RAL 7021, Plug straight M12, A-coded, on Plug straight M12, A-coded, M12 Y-distributor, for outdoor applications, with high-grade steel knurl

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top