| Parameter | Value |
|---|---|
| according to IEC 60754-1 | |
| Type | Plug straight M12 |
| Coding | T |
| Shielded | yes |
| Cable type | PUR halogen-free black [PUR] |
| Application | Power supply |
| Coding type | T (Power) |
| Cable length | 5 m |
| Cable weight | 133 kg/km |
| Halogen-free | in accordance with DIN VDE 0472 part 815 |
| Product type | Power cable |
| Test voltage | 1500 V AC (5 min.) |
| UL AWM Style | 20233 / 10493 (80°C/300 V) |
| Overall twist | 4 wires optimally twisted |
| Article revision | 06 |
| Contact material | CuZn |
| Flame resistance | in accordance with EN 60332-1-2 |
| Resistance to oil | in accordance with DIN EN 60811-2-1 |
| Conductor material | Bare Cu litz wires |
| Nominal current IN | 12 A |
| Nominal voltage UN | 63 V DC |
| Single wire, color | brown, white, blue, black |
| Degree of pollution | 3 |
| Dimensional drawing | |
| Number of positions | 4 |
| Degree of protection | IP65 |
| No. of cable outlets | 1 |
| Overvoltage category | III |
| Standard designation | M12 connector |
| Insulation resistance | ≥ 100 MΩ |
| Material of grip body | PP |
| Thickness, insulation | 1.20 mm (Outer cable sheath) |
| External sheath, color | black RAL 9005 |
| Nominal voltage, cable | 300 V AC |
| Outer sheath, material | PUR |
| Conductor cross section | 4x 1.5 mm² |
| External cable diameter | 9.70 mm ±0.3 mm |
| Contact carrier material | PA |
| Contact surface material | Ni/Au |
| Material wire insulation | PP |
| Standards/specifications | IEC 61076-2-111 |
| Max. conductor resistance | ≤ 13.3 Ω/km (at 20 °C) |
| Insertion/withdrawal cycles | > 100 |
| Material for screw connection | Zinc die-cast, nickel-plated |
| Wire diameter incl. insulation | 2.4 mm |
| Ambient temperature (operation) | -40 °C ... 90 °C (cable, fixed installation) |
| Dynamic load capacity (bending) | Max. bending cycles: 4000000, Bending radius: 97 mm, Traversing path: 10 m, Traversing rate: 3 m/s, Acceleration: 10 m/s² |
| Dynamic load capacity (torsion) | Torsion: ±25 °/m |
| Flammability rating according to UL 94 | V0 |
| Smallest bending radius, fixed installation | 49 mm |
| Smallest bending radius, movable installation | 73 mm |
Technical specifications and performance data