Technical Specifications

ParameterValue
GTIN4055626898674
(Cable)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey1089999
(Drawings)
Packing unit1 pc
(Dimensions)IP67
Country of originPL (Poland)
ETIM 5.0 (eCl@ss)EC001855
ETIM 6.0 (eCl@ss)EC001855
ETIM 7.0 (eCl@ss)EC001855
China RoHS (Cable)Environmentally Friendly Use Period = 50
REACh SVHC (Cable)
Custom tariff number85444290
Contact material (General)CuZn
Length of cable (Drawings)10 m
Material, knurls (General)Zinc die-cast, nickel-plated
Coding (Ambient conditions)T power
(Standards and Regulations)-20 °C ... 80 °C (cable, flexible installation)
eCl@ss 6.0 (Classifications)27279200
eCl@ss 7.0 (Classifications)27279218
eCl@ss 8.0 (Classifications)27279218
eCl@ss 9.0 (Classifications)27060311
Material of grip body (General)PP
Degree of protection (Dimensions)IP65
Contact carrier material (General)PA
Contact surface material (General)Ni/Au
Rated voltage (Ambient conditions)63 V DC
Standards/specifications (Material)M12 connector IEC 61076-2-111
Status display (Ambient conditions)No
Weight per Piece (excluding packing)1,080.000 g
Cable type (Standards and Regulations)PVC black
Wire colors (Standards and Regulations)brown, white, blue, black
Acceleration (Standards and Regulations)10 m/s²
Degree of pollution (Ambient conditions)3
Number of positions (Ambient conditions)4
UL AWM style (Standards and Regulations)20233 / 10493 (80°C/300 V)
Overvoltage category (Ambient conditions)III
Insulation resistance (Ambient conditions)≥ 100 MΩ
Standards/regulations (Ambient conditions)M12 connector IEC 61076-2-111
Rated current at 40°C (Ambient conditions)12 A
Traversing path (Standards and Regulations)10 m
Traversing rate (Standards and Regulations)3 m/s
AWG power supply (Standards and Regulations)16
Ambient temperature (operation) (Dimensions)-25 °C ... 85 °C (Plug / socket)
Flame resistance (Standards and Regulations)According to UL 758/1581 (Cable Flame)
Resistance to oil (Standards and Regulations)According to DIN EN 60811-404, 168 h at 60 °C
Conductor material (Standards and Regulations)Bare Cu litz wires
Test voltage, cable (Standards and Regulations)≥ 3000 V AC (Spark test)
Conductor resistance (Standards and Regulations)≤ 13 Ω/km (at 20 °C)
Flammability rating according to UL 94 (General)V0
Insertion/withdrawal cycles (Ambient conditions)> 100
Flammability rating according to UL 94 (Material)V0
Insulation resistance (Standards and Regulations)≥ 1 GΩ*km (at 20 °C)
Protective circuit/component (Ambient conditions)unwired
Thickness, insulation (Standards and Regulations)≥ 0.25 mm
External sheath, color (Standards and Regulations)black-gray RAL 7021
Nominal voltage, cable (Standards and Regulations)≤ 300 V AC
Outer sheath thickness (Standards and Regulations)approx. 1.3 mm
Outer sheath, material (Standards and Regulations)PVC
Conductor cross section (Standards and Regulations)4x 1.5 mm²
Number of bending cycles (Standards and Regulations)2000000
Cable type (abbreviation) (Standards and Regulations)110
Dimensional drawingPlug, M12 x 1, straight (Drawings)
External cable diameter D (Standards and Regulations)7.55 mm ±0.25 mm
Material conductor insulation (Standards and Regulations)PVC
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 80 °C (cable, fixed installation)
Core diameter including insulation (Standards and Regulations)2.35 mm ±0.05 mm
Conductor structure, voltage supply (Standards and Regulations)78x 0.15 mm
Minimum bending radius, fixed installation (Standards and Regulations)5 x D
Minimum bending radius, flexible installation (Standards and Regulations)10 x D
Minimum bending radius, drag chain applications (Standards and Regulations)10 x D
Circuit diagramContact assignment of the M12 connector and the M12 socket (Drawings)
Schematic diagramPin assignment of M12 socket, 4-pos., T-coded, socket side view (Drawings)

Product Description

Power cable, 4-pole, M12 straight connector, encoding: T, to M12 straight female, encoding: T, cable length: 10 m, for direct current up to 12 A/63 V
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Dimensional drawingPlug, M12 x 1, straight

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top