SAC-4P-M12MST/ 1,5-PUR/M12FST - SAC-4P-M12MST/ 1,5-PUR/M12FST 1413211 PHOENIX CONTACT Power cable SAC-4P-M12MST/ 1,5-PUR/M12FST 1413211
In Stock Hot Product

SAC-4P-M12MST/ 1,5-PUR/M12FST

SAC-4P-M12MST/ 1,5-PUR/M12FST 1413211 PHOENIX CONTACT Power cable SAC-4P-M12MST/ 1,5-PUR/M12FST 1413211

$0.00USD
4880 in stock
Key Specifications
GTIN:4046356994576
(Cable):For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey:1413211
Packing unit:1
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356994576
(Cable)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey1413211
Packing unit1
(Dimensions)IP67
ETIM 4.0 (eCl@ss)EC001855
ETIM 5.0 (eCl@ss)EC001855
ETIM 6.0 (eCl@ss)EC001855
ETIM 7.0 (eCl@ss)EC001855
China RoHS (Cable)Environmentally Friendly Use Period = 50
REACh SVHC (Cable)
UNSPSC 13.2 (ETIM)31251501
Custom tariff number85444290
Contact material (General)CuSn
Material, knurls (General)Zinc die-cast, nickel-plated
Coding (Ambient conditions)T power
(Standards and Regulations)-30 °C ... 80 °C (cable, flexible installation)
eCl@ss 5.1 (Classifications)27143400
eCl@ss 6.0 (Classifications)27279200
eCl@ss 7.0 (Classifications)27279218
eCl@ss 8.0 (Classifications)27279218
eCl@ss 9.0 (Classifications)27060311
Material of grip body (General)PA
Standard designation (Material)M12 connector
Standards/regulations (Material)IEC 61076-2-111
Degree of protection (Dimensions)IP65
Contact carrier material (General)PA
Contact surface material (General)Ni/Au
Rated voltage (Ambient conditions)63 V DC
Status display (Ambient conditions)No
Length of cable (Key Commercial Data)1.5 m
Cable type (Standards and Regulations)PUR halogen-free black
Wire colors (Standards and Regulations)brown, white, blue, black
Acceleration (Standards and Regulations)10 m/s²
Cable weight (Standards and Regulations)109 kg/km
Degree of pollution (Ambient conditions)3
Halogen-free (Standards and Regulations)in accordance with DIN VDE 0472 part 815
Number of positions (Ambient conditions)4
UL AWM style (Standards and Regulations)20233 / 10493 (80°C/300 V)
Overall twist (Standards and Regulations)4 wires, twisted
Overvoltage category (Ambient conditions)III
Insulation resistance (Ambient conditions)≥ 100 MΩ
Standards/regulations (Ambient conditions)M12 connector IEC 61076-2-111
Rated current at 40°C (Ambient conditions)12 A
Traversing path (Standards and Regulations)10 m
Traversing rate (Standards and Regulations)3 m/s
AWG power supply (Standards and Regulations)16
Ambient temperature (operation) (Dimensions)-25 °C ... 85 °C (Plug / socket)
Flame resistance (Standards and Regulations)According to UL 758/1581 (Cable Flame)
Other resistance (Standards and Regulations)Hydrolysis and microbe resistant as per VDE 0282 section 10
Resistance to oil (Standards and Regulations)According to DIN EN 60811-2-1, 168 h at 100°C
Cable abbreviation (Standards and Regulations)Li9YV1-11Y
Conductor material (Standards and Regulations)Bare Cu litz wires
Test voltage, cable (Standards and Regulations)≥ 3000 V AC (Spark test)
Conductor resistance (Standards and Regulations)≤ 13 Ω/km (at 20 °C)
Flammability rating according to UL 94 (General)V0
Insertion/withdrawal cycles (Ambient conditions)> 100
Flammability rating according to UL 94 (Material)V0
Insulation resistance (Standards and Regulations)≥ 1 GΩ*km (at 20 °C)
Protective circuit/component (Ambient conditions)unwired
Thickness, insulation (Standards and Regulations)≥ 0.25 mm
External sheath, color (Standards and Regulations)black-gray RAL 7021
Nominal voltage, cable (Standards and Regulations)≤ 300 V AC
Outer sheath thickness (Standards and Regulations)approx. 1.3 mm
Outer sheath, material (Standards and Regulations)PUR
Conductor cross section (Standards and Regulations)4x 1.5 mm²
Number of bending cycles (Standards and Regulations)4000000
Cable type (abbreviation) (Standards and Regulations)PUR
External cable diameter D (Standards and Regulations)8.4 mm ±0.25 mm
Material conductor insulation (Standards and Regulations)PP
Length of twist, overall twist (Standards and Regulations)90 mm
Ambient temperature (operation) (Standards and Regulations)-50 °C ... 80 °C (cable, fixed installation)
Core diameter including insulation (Standards and Regulations)2.35 mm ±0.05 mm
Conductor structure, voltage supply (Standards and Regulations)78x 0.15 mm
Minimum bending radius, fixed installation (Standards and Regulations)5 x D
Minimum bending radius, flexible installation (Standards and Regulations)10 x D
Minimum bending radius, drag chain applications (Standards and Regulations)10 x D

Product Description

Power cable, 4-pole halogen-free, M12 straight connector, encoding: T, to M12 straight female, encoding: T, cable length: 1.5 m, for direct current up to 12 A/63 V
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Power cable, 4-position, PUR halogen-free, black-gray RAL 7021, Plug straight M12, T-coded, on Socket straight M12, T-coded, cable length: 1.5 m

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide