| Parameter | Value |
|---|---|
| EAN | Four trillion fifty five billion six hundred twenty six million three hundred eighty one thousand eight |
| (Cable) | You will find information about hazardous substances in the manufacturer's declaration in the "Downloads"tab |
| Key order | One million four hundred twenty four thousand seven hundred twenty nine |
| (Measures) | IP67 |
| Key selling | BF1CCP - |
| Packing unit | 1 pcs |
| Country of origin | DE (Germany) |
| ETIM 6.0 (eCl@ss) | EC001855 |
| ETIM 7.0 (eCl@ss) | EC001855 |
| China RoHS (Cable) | Space of time for the intended use (FEUP): 50 years |
| REACh SVHC (Cable) | |
| Tariff number tariff | Eighty five million four hundred forty four thousand two hundred ninety |
| eCl@ss 6.0 (Ratings) | Twenty seven million two hundred seventy nine thousand two hundred |
| eCl@ss 7.0 (Ratings) | Twenty seven million two hundred seventy nine thousand two hundred eighteen |
| eCl@ss 9.0 (Ratings) | Twenty seven million sixty thousand three hundred eleven |
| Minimum order quantity | 50 pcs |
| Material contact (Overview) | CuZn |
| Material knurled (Overview) | Die-cast zinc, nickel plated |
| Name of standard (Material) | Plug-in connector M12 |
| Material body grip (Overview) | PA |
| Cable length (Data commercial) | 2.4 m |
| Index of protection (Measures) | IP65 |
| (Standards and specifications) | -30 °C ... 80 °C (cable, available mobile) |
| Unit weight (excluding packaging) | 22,220 g |
| Encoding (Environmental conditions) | S - Power |
| Material contact surface (Overview) | Ni/Au |
| Standards/specifications (Material) | IEC 61076-2-111 |
| Room temperature (service) (Measures) | -25 °C ... 85 °C (male / female) |
| Material support of contacts (Overview) | PA |
| Category surge (Environmental conditions) | III |
| Cycles of plug (Environmental conditions) | > 100 |
| Tension sizing (Environmental conditions) | 690 V AC |
| Number of poles (Environmental conditions) | Four |
| Acceleration (Standards and specifications) | 10 m/s2 |
| Pollution degree (Environmental conditions) | Three |
| UL AWM Style (Standards and specifications) | 20234 / 10492 (80 °C/1000 V) |
| Cabling total (Standards and specifications) | 4-conductor longitudinally twisted |
| Colors driver (Standards and specifications) | black 1, black 2, black 3, green / yellow |
| Forward speed (Standards and specifications) | 3 m/s |
| Status indication (Environmental conditions) | Not |
| Tightening torque (Environmental conditions) | 0.4 Nm (M12 Connector) |
| Type of cable (Standards and specifications) | PUR halogen-free black |
| Oil resistance (Standards and specifications) | according to DIN en 60811-2-1, 168 h at 100 °C |
| Journey forward (Standards and specifications) | 10 m |
| Other resistors (Standards and specifications) | resistant to hydrolysis and microbes according to VDE 0282 part 10 |
| Flame resistance (Standards and specifications) | According to UL 758/1581 (Cable Flame) |
| Power supply AWG (Standards and specifications) | Sixteen |
| Insulation resistance (Environmental conditions) | ≥ 100 MΩ |
| Outer wrap, color (Standards and specifications) | black-grey RAL 7021 |
| Section of driver (Standards and specifications) | 4x 1.5 mm2 |
| Absence of halogen (Standards and specifications) | according to DIN VDE 0472 part 815 |
| Color of the grip area (Environmental conditions) | black |
| Test voltage Cable (Standards and specifications) | ≥ 10000 V AC Test (spark) |
| Conductive Material (Standards and specifications) | Conductor Cu bare |
| Rated voltage Cable (Standards and specifications) | ≤ 1000 V AC |
| Weight of the cable (Standards and specifications) | 114 kg/km |
| Class of flammability according to UL 94 (Material) | V0 |
| Class of flammability according to UL 94 (Overview) | V0 |
| Current sizing at 40 °C (Environmental conditions) | 12 To |
| Standards/specifications (Environmental conditions) | Plug-in connector M12 IEC 61076-2-111 |
| Step of wiring total (Standards and specifications) | 93 mm |
| Abbreviation of cable (Standards and specifications) | Li9YV1-11Y |
| Insulation resistance (Standards and specifications) | ≥ 1 GΩ*km (at 20 °C) |
| Outer casing, material (Standards and specifications) | PUR |
| Number of bending cycles (Standards and specifications) | Two million |
| Cable type (abbreviation) (Standards and specifications) | PUR |
| Outer diameter of cable D (Standards and specifications) | 8,8 mm ±0.25 mm |
| Wall thickness outer wrap (Standards and specifications) | approx. 1.3 mm |
| Room temperature (service) (Standards and specifications) | -50 °C ... 80 °C (cable, fixed) |
| Resistance of the conductor (Standards and specifications) | ≤ 13 Ω/km (at 20 °C) |
| Thickness of wall Insulation (Standards and specifications) | ≥ 0.36 mm |
| Material Insulation conductor (Standards and specifications) | PP |
| Protective circuit/component protection (Environmental conditions) | without connect |
| Radius of curvature, insert drag chains (Standards and specifications) | 10 x D |
| Construction of the driver voltage supply (Standards and specifications) | 78x 0.15 mm |
| Diameter of the conductors, insulation included (Standards and specifications) | 2,45 mm ±0.05 mm |
| Minimum bending radius, placed in a fixed manner (Standards and specifications) | 5 x D |
| Minimum bending radius, placed in a flexible way (Standards and specifications) | 10 x D |
Technical specifications and performance data
Installation and operation guide