Service time: Monday to Friday 9:00-18:00
SAC-4P-M12MSS/10-PUR/FRS PE SH - SAC-4P-M12MSS/10-PUR/FRS PE SH 1065586 PHOENIX CONTACT Power cable, 4-position, PUR halogen-free, orange RAL..
In Stock Hot Product

SAC-4P-M12MSS/10-PUR/FRS PE SH

SAC-4P-M12MSS/10-PUR/FRS PE SH 1065586 PHOENIX CONTACT Power cable, 4-position, PUR halogen-free, orange RAL..

$0.00USD
3702 in stock
Key Specifications
GTIN:4055626728421
(Cable):For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey:1065586
(Drawings):
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626728421
(Cable)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey1065586
(Drawings)
Packing unit1
(Dimensions)IP67
UNSPSC 11 (ETIM)31251501
ETIM 2.0 (eCl@ss)EC000830
ETIM 3.0 (eCl@ss)EC001855
ETIM 4.0 (eCl@ss)EC001855
ETIM 5.0 (eCl@ss)EC001855
ETIM 6.0 (eCl@ss)EC001855
ETIM 7.0 (eCl@ss)EC001855
China RoHS (Cable)Environmentally Friendly Use Period = 50
REACh SVHC (Cable)
UNSPSC 13.2 (ETIM)31251501
UNSPSC 19.0 (ETIM)31251501
UNSPSC 20.0 (ETIM)31251501
UNSPSC 21.0 (ETIM)31251501
UNSPSC 6.01 (ETIM)31251501
UNSPSC 12.01 (ETIM)31251501
Custom tariff number85444290
UNSPSC 7.0901 (ETIM)31251501
Contact material (General)CuZn
Length of cable (Drawings)10 m
Material, knurls (General)Zinc die-cast, nickel-plated
Coding (Ambient conditions)S power
Torque (Ambient conditions)0.4 Nm (M12 connector)
(Standards and Regulations)-30 °C ... 90 °C (cable, flexible installation)
eCl@ss 4.0 (Classifications)27060306
eCl@ss 4.1 (Classifications)27060306
eCl@ss 5.0 (Classifications)27061801
eCl@ss 5.1 (Classifications)27061801
eCl@ss 6.0 (Classifications)27279200
eCl@ss 7.0 (Classifications)27279218
eCl@ss 8.0 (Classifications)27279218
eCl@ss 9.0 (Classifications)27060311
Material of grip body (General)PP
Degree of protection (Dimensions)IP65
Contact carrier material (General)PA
Contact surface material (General)Ni/Au
Rated voltage (Ambient conditions)690 V AC
Standards/specifications (Material)M12 connector IEC 61076-2-111
Status display (Ambient conditions)No
Shielding (Standards and Regulations)Tinned copper-braided shield, approx. 85% covering
Cable type (Standards and Regulations)PUR halogen-free orange shielded
Color handle area (Ambient conditions)black
Wire colors (Standards and Regulations)Black 1, black 2, black 3, green/yellow
Acceleration (Standards and Regulations)10 m/s²
Degree of pollution (Ambient conditions)3
Halogen-free (Standards and Regulations)according to VDE 0282-13 Appendix C
Number of positions (Ambient conditions)4
UL AWM style (Standards and Regulations)20234 / 10492 (80°C/1000 V)
Overall twist (Standards and Regulations)4 wires optimally twisted
Overvoltage category (Ambient conditions)III
Torsion force (Standards and Regulations)± 25 °/m
Insulation resistance (Ambient conditions)≥ 100 MΩ
Standards/regulations (Ambient conditions)M12 connector IEC 61076-2-111
Rated current at 40°C (Ambient conditions)12 A
Traversing path (Standards and Regulations)10 m
Traversing rate (Standards and Regulations)3 m/s
AWG power supply (Standards and Regulations)16
Ambient temperature (operation) (Dimensions)-25 °C ... 85 °C (Plug / socket)
Flame resistance (Standards and Regulations)according to EN 60332-1-2
Other resistance (Standards and Regulations)UV resistant
Resistance to oil (Standards and Regulations)in accordance with DIN EN 60811-2-1
Cable abbreviation (Standards and Regulations)9YSLC11Y-JZ
Conductor material (Standards and Regulations)Bare Cu litz wires
Test voltage, cable (Standards and Regulations)4260 V AC (5 min.)
Conductor resistance (Standards and Regulations)≤ 13.3 Ω/km (at 20 °C)
Flammability rating according to UL 94 (General)V0
Insertion/withdrawal cycles (Ambient conditions)> 100
Flammability rating according to UL 94 (Material)V0
Insulation resistance (Standards and Regulations)≥ 10 MΩ*km (at 20 °C)
Protective circuit/component (Ambient conditions)unwired
Thickness, insulation (Standards and Regulations)0.4 mm
External sheath, color (Standards and Regulations)orange RAL 2003
Nominal voltage, cable (Standards and Regulations)1000 V AC
Outer sheath thickness (Standards and Regulations)1.2 mm
Outer sheath, material (Standards and Regulations)PUR
Conductor cross section (Standards and Regulations)4x 1.5 mm²
Number of bending cycles (Standards and Regulations)4000000
Cable type (abbreviation) (Standards and Regulations)PUR
External cable diameter D (Standards and Regulations)9.7 mm ±0,3 mm
Material conductor insulation (Standards and Regulations)PP
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 90 °C (cable, fixed installation)
Circuit diagramContact assignment of the M12 plug (Drawings)
Core diameter including insulation (Standards and Regulations)≤ 2.5 mm
Conductor structure, voltage supply (Standards and Regulations)78x 0.15 mm
Dimensional drawingPlug, M12 x 1, straight, shielded (Drawings)
Minimum bending radius, fixed installation (Standards and Regulations)5 x D
Minimum bending radius, flexible installation (Standards and Regulations)7.5 x D
Minimum bending radius, drag chain applications (Standards and Regulations)10 x D
Schematic diagramPin assignment of M12 socket, 4-pos., S-coded, socket side view (Drawings)

Product Description

Power cable, 4-pole halogen-free, shielded (Advanced Shielding Technology), Straight M12 connector, coding: S, to Elbow Female M12, coding: S, cable length: 10 m, for alternating current up to 12 A/69
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Dimensional drawingPlug, M12 x 1, straight, shielded

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top