Service time: Monday to Friday 9:00-18:00
SAC-4P-M12MSS/0,5-PUR PE 0,07 - SAC-4P-M12MSS/0,5-PUR PE 0,07 1426090 PHOENIX CONTACT Power Cable, 4-pole, PUR halogen-free, black-gray RAL ..
In Stock Hot Product

SAC-4P-M12MSS/0,5-PUR PE 0,07

SAC-4P-M12MSS/0,5-PUR PE 0,07 1426090 PHOENIX CONTACT Power Cable, 4-pole, PUR halogen-free, black-gray RAL ..

$0.00USD
3121 in stock
Key Specifications
GTIN:Four trillion fifty five billion six hundred twenty six million four hundred forty six thousand one hundred sixty five
(Cable):Information on hazardous substances is given in the manufacturer's Declaration in tab "Download"
Order code:One million four hundred twenty six thousand ninety
(Dimensions):IP67
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTINFour trillion fifty five billion six hundred twenty six million four hundred forty six thousand one hundred sixty five
(Cable)Information on hazardous substances is given in the manufacturer's Declaration in tab "Download"
Order codeOne million four hundred twenty six thousand ninety
(Dimensions)IP67
Packaging unitOne
ETIM 6.0 (eCl@ss)EC001855
ETIM 7.0 (eCl@ss)EC001855
China RoHS (Cable)The time period for use (EFUP) of 50 years
REACh SVHC (Cable)
Poles (Ambient conditions)Four
Coding (Ambient conditions)S - Power
eCl@ss 6.0 (Classification)Twenty seven million two hundred seventy nine thousand two hundred
eCl@ss 7.0 (Classification)Twenty seven million two hundred seventy nine thousand two hundred eighteen
eCl@ss 9.0 (Classification)Twenty seven million sixty thousand three hundred eleven
(Standards and regulations)-30 °C ... 80 °C (cable, for flexible installation)
Cable length (Commercial data)0.5 m
Color handle (Ambient conditions)black
Degree of protection (Dimensions)IP65
Rated voltage (Ambient conditions)690 V AC
Travel (Standards and regulations)10 m
Pollution degree (Ambient conditions)Three
Status indicator (Ambient conditions)No
Cable type (Standards and regulations)PUR zero halogen black
Tightening torque (Ambient conditions)0.4 Nm (M12 Connector)
Color lived (Standards and regulations)black 1, black 2, black 3, green/yellow
Material, contact (General information)CuZn
AWG, voltage (Standards and regulations)Sixteen
Acceleration (Standards and regulations)10 m/S2
Cycles installation (Ambient conditions)> 100
Halogen-free (Standards and regulations)according to DIN VDE 0472 part 815
Symbol cable (Standards and regulations)Li9YV1-11Y
UL AWM Style (Standards and regulations)20234 / 10492 (80 °C / 1000 V)
Oil resistant (Standards and regulations)according to DIN EN 60811-2-1, 168 h at 100 °C
Overvoltage category (Ambient conditions)III
Insulation resistance (Ambient conditions)≥ 100 MΩ
Standards / normative documents (Material)IEC 61076-2-111
The designation of the standard (Material)M12 Connector
Body material handles (General information)PA
Material knurled nuts (General information)Zinc. diecast, Nickel-plated
Weight of cable (Standards and regulations)114 kg/km
Ambient temperature (operating) (Dimensions)-25 °C ... 85 °C (plug / socket)
General twisting (Standards and regulations)4 wires in the strand
Incombustibility (Standards and regulations)according to UL 758/1581 (burning cables)
Rated current at 40 ℃ (Ambient conditions)12 A
Conductor material (Standards and regulations)copper flexible wire
Material contact surface (General information)Ni/Au
Outer shell, color (Standards and regulations)dark gray RAL 7021
Wire cross-section (Standards and regulations)4x 1.5 mm2
Step total twisting (Standards and regulations)93 mm
Protective circuit / module (Ambient conditions)without wiring diagrams
Vitality, other data (Standards and regulations)Resistance to hydrolysis and microbes in accordance with VDE 0282, part 10
Insulation resistance (Standards and regulations)≥ 1 ГΩ*km (at 20 °C)
The material holder contact (General information)PA
Outer sheath, material (Standards and regulations)PUR
Standards/normative documents (Ambient conditions)M12 connector IEC 61076-2-111
Class of Flammability according to UL 94 (Material)V0
Test voltage, conductor (Standards and regulations)≥ 10,000 AC (Test for spark)
Outer diameter of cable D (Standards and regulations)8,8 mm ±0.25 mm
Cable design, power supply (Standards and regulations)78x 0.15 mm
Nominal voltage, conductor (Standards and regulations)≤ 1000 V AC
Wall thickness, insulation (Standards and regulations)≥ 0.36 mm
The resistance of the cable (Standards and regulations)≤ 13 Ohm/km (at 20 °C)
The number of bending cycles (Standards and regulations)Two million
Material conductor insulation (Standards and regulations)PP
The speed of lateral movement (Standards and regulations)3 m/c
Cable type (short designation) (Standards and regulations)polyurethane
Ambient temperature (operating) (Standards and regulations)-50 °C ... 80 °C (cable firmly laid)
Class of Flammability according to UL 94 (General information)V0
Conductor diameter incl. insulation (Standards and regulations)2,45 mm ±0.05 mm
Minimum bending radius, rigid strip (Standards and regulations)5 x D
The wall thickness of the outer shell (Standards and regulations)about 1.3 mm
Minimum bending radius, flexible strip (Standards and regulations)10 x D
Minimum bending radius for use in tow chains (Standards and regulations)10 x D

Product Description

Power cable, 4-pole, halogen-free PUR, grayish black RAL 7021, Straight male connector M12, coding: S, to free cable end, cable length: 0.5 m, for alternating current up to 12 A/690 V
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Power cable, 4 -, Sz., PUR halogen-free, dark gray RAL 7021, Plug straight M12, S-coded, to a free end, cable length: 0.5 m, for AC current up to 12 A / 690 V

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide