| Parameter | Value |
|---|---|
| GTIN | Four trillion fifty five billion six hundred twenty six million four hundred forty six thousand one hundred sixty five |
| (Cable) | Information on hazardous substances is given in the manufacturer's Declaration in tab "Download" |
| Order code | One million four hundred twenty six thousand ninety |
| (Dimensions) | IP67 |
| Packaging unit | One |
| ETIM 6.0 (eCl@ss) | EC001855 |
| ETIM 7.0 (eCl@ss) | EC001855 |
| China RoHS (Cable) | The time period for use (EFUP) of 50 years |
| REACh SVHC (Cable) | |
| Poles (Ambient conditions) | Four |
| Coding (Ambient conditions) | S - Power |
| eCl@ss 6.0 (Classification) | Twenty seven million two hundred seventy nine thousand two hundred |
| eCl@ss 7.0 (Classification) | Twenty seven million two hundred seventy nine thousand two hundred eighteen |
| eCl@ss 9.0 (Classification) | Twenty seven million sixty thousand three hundred eleven |
| (Standards and regulations) | -30 °C ... 80 °C (cable, for flexible installation) |
| Cable length (Commercial data) | 0.5 m |
| Color handle (Ambient conditions) | black |
| Degree of protection (Dimensions) | IP65 |
| Rated voltage (Ambient conditions) | 690 V AC |
| Travel (Standards and regulations) | 10 m |
| Pollution degree (Ambient conditions) | Three |
| Status indicator (Ambient conditions) | No |
| Cable type (Standards and regulations) | PUR zero halogen black |
| Tightening torque (Ambient conditions) | 0.4 Nm (M12 Connector) |
| Color lived (Standards and regulations) | black 1, black 2, black 3, green/yellow |
| Material, contact (General information) | CuZn |
| AWG, voltage (Standards and regulations) | Sixteen |
| Acceleration (Standards and regulations) | 10 m/S2 |
| Cycles installation (Ambient conditions) | > 100 |
| Halogen-free (Standards and regulations) | according to DIN VDE 0472 part 815 |
| Symbol cable (Standards and regulations) | Li9YV1-11Y |
| UL AWM Style (Standards and regulations) | 20234 / 10492 (80 °C / 1000 V) |
| Oil resistant (Standards and regulations) | according to DIN EN 60811-2-1, 168 h at 100 °C |
| Overvoltage category (Ambient conditions) | III |
| Insulation resistance (Ambient conditions) | ≥ 100 MΩ |
| Standards / normative documents (Material) | IEC 61076-2-111 |
| The designation of the standard (Material) | M12 Connector |
| Body material handles (General information) | PA |
| Material knurled nuts (General information) | Zinc. diecast, Nickel-plated |
| Weight of cable (Standards and regulations) | 114 kg/km |
| Ambient temperature (operating) (Dimensions) | -25 °C ... 85 °C (plug / socket) |
| General twisting (Standards and regulations) | 4 wires in the strand |
| Incombustibility (Standards and regulations) | according to UL 758/1581 (burning cables) |
| Rated current at 40 ℃ (Ambient conditions) | 12 A |
| Conductor material (Standards and regulations) | copper flexible wire |
| Material contact surface (General information) | Ni/Au |
| Outer shell, color (Standards and regulations) | dark gray RAL 7021 |
| Wire cross-section (Standards and regulations) | 4x 1.5 mm2 |
| Step total twisting (Standards and regulations) | 93 mm |
| Protective circuit / module (Ambient conditions) | without wiring diagrams |
| Vitality, other data (Standards and regulations) | Resistance to hydrolysis and microbes in accordance with VDE 0282, part 10 |
| Insulation resistance (Standards and regulations) | ≥ 1 ГΩ*km (at 20 °C) |
| The material holder contact (General information) | PA |
| Outer sheath, material (Standards and regulations) | PUR |
| Standards/normative documents (Ambient conditions) | M12 connector IEC 61076-2-111 |
| Class of Flammability according to UL 94 (Material) | V0 |
| Test voltage, conductor (Standards and regulations) | ≥ 10,000 AC (Test for spark) |
| Outer diameter of cable D (Standards and regulations) | 8,8 mm ±0.25 mm |
| Cable design, power supply (Standards and regulations) | 78x 0.15 mm |
| Nominal voltage, conductor (Standards and regulations) | ≤ 1000 V AC |
| Wall thickness, insulation (Standards and regulations) | ≥ 0.36 mm |
| The resistance of the cable (Standards and regulations) | ≤ 13 Ohm/km (at 20 °C) |
| The number of bending cycles (Standards and regulations) | Two million |
| Material conductor insulation (Standards and regulations) | PP |
| The speed of lateral movement (Standards and regulations) | 3 m/c |
| Cable type (short designation) (Standards and regulations) | polyurethane |
| Ambient temperature (operating) (Standards and regulations) | -50 °C ... 80 °C (cable firmly laid) |
| Class of Flammability according to UL 94 (General information) | V0 |
| Conductor diameter incl. insulation (Standards and regulations) | 2,45 mm ±0.05 mm |
| Minimum bending radius, rigid strip (Standards and regulations) | 5 x D |
| The wall thickness of the outer shell (Standards and regulations) | about 1.3 mm |
| Minimum bending radius, flexible strip (Standards and regulations) | 10 x D |
| Minimum bending radius for use in tow chains (Standards and regulations) | 10 x D |