| Parameter | Value |
|---|---|
| 60 V DC | |
| Shielded | Yes |
| Cable type | CANopen®/DeviceNet™, PUR, violet [920] |
| Pair wiring | 2 conductors as pair |
| Plug Cycles | ≥ 100 |
| Cable Weight | 90 kg/km |
| Cable length | 50 m |
| Codification | B |
| Construction | M12 Straight Connector |
| Line Section | 2x 0.25 mm² (Data Line) |
| Product Type | Ready-made data cable |
| UL AWM Style | 21198 (80°C/300V) |
| Encoding Type | B (Standard) |
| Line Capacity | Nom. 40 nF/km (Data Line) |
| Total cabling | 2 pairs around a reference conductor in the center as the core |
| Screen dimming | ≤ 22.9 dB/km (at 1 MHz) |
| Self-impedance | 120 Ω ±10% (with 1 MHz) |
| Surge Category | Ii |
| AWG Signal Line | 24 |
| Gasket material | NBR |
| Number of poles | 4 |
| Conductor Design | 2xAWG24/19+2xAWG22/19 |
| Contact material | CuSn |
| Dimension Scheme | |
| Flame Resistance | IEC 60332-1-2 |
| Protection Index | IP65 |
| Other resistances | Non-adherent |
| Outer Wrap, Color | lilac red RAL 4001 |
| Status Indication | No |
| Contact resistance | ≤ 5 mΩ |
| Grip body material | Fire-resistant, self-extinguishing TPU |
| Nominal Current IN | 4 A |
| Nominal voltage UN | 48 V AC |
| Absence of halogens | according to DIN VDE 0472 part 815 |
| Conductive Material | Tinned Cu Conductor |
| Degree of pollution | 3 |
| Max. bending cycles | 5000000 |
| Pair Shielding Type | Plastic Coated Aluminum Sheet, Outer Aluminum Side |
| Visual Screen Cover | 80 % |
| Cable Outer Diameter | 6.7 mm ±0.3 mm |
| Outer Wrap, Material | PUR |
| Polishing resistance | ≤ 181.80 Ω/km (Data line) |
| Single Driver, Color | red-black, blue-white |
| Insulation resistance | ≥ 100 MΩ |
| Nominal Voltage Cable | ≤ 300 V (Peak value, not suitable for high intensity) |
| Number of Cable Outlets | 1 |
| Contact Support Material | TPU GF |
| Material: Contact Surface | Ni/AU |
| Screw connection material | Zinc die-cast iron, nickel-plated |
| Available Status Indication | No |
| Ambient Temperature (Service) | -40 °C ... 80°C (cable, fixed arrangement) |
| Minimum bending radius, fixed | 5 x D |
| Material: Conductor Insulation | Foamed PE (Data Line) |
| Test Voltage Conductor/Display | 2000 V (50 Hz, 1 min.) |
| Test Voltage Conductor/Conductor | 2000 V (50 Hz, 1 min.) |
| Conductor Construction Signal Cable | 19x 0.13 mm |
| Conductor diameter incl. insulation | 1.95 mm ±0.05 mm (Data Line) |
| Flammability class according to UL 94 | HB |
| Smaller bending radius, fixed mounting | 34 mm |
| Smaller bending radius, movable mounting | 67 mm |
| Minimum bending radius, flexibly positioned | 10 x D |
Technical specifications and performance data