Service time: Monday to Friday 9:00-18:00
SAC-4P-M12MSB/ 2,0-920/FSB X2X - SAC-4P-M12MSB/ 2,0-920/FSB X2X 1416298 PHOENIX CONTACT Bus system cable SAC-4P-M12MSB/2-920/M12FSB X2X 14162..
In Stock Hot Product

SAC-4P-M12MSB/ 2,0-920/FSB X2X

SAC-4P-M12MSB/ 2,0-920/FSB X2X 1416298 PHOENIX CONTACT Bus system cable SAC-4P-M12MSB/2-920/M12FSB X2X 14162..

$0.00USD
4898 in stock
Key Specifications
GTIN:4055626067629
(Cable):No hazardous substances above threshold values
Orderkey:1416298
Packing unit:1
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626067629
(Cable)No hazardous substances above threshold values
Orderkey1416298
Packing unit1
(Dimensions)60 V DC
ETIM 5.0 (eCl@ss)EC001855
ETIM 6.0 (eCl@ss)EC001855
ETIM 7.0 (eCl@ss)EC001855
China RoHS (Cable)Environmentally friendly use period: unlimited = EFUP-e
UNSPSC 13.2 (ETIM)31251501
Coding (Dimensions)B-coded
Custom tariff number85444290
Contact material (General)CuSn
Material, knurls (General)Zinc die-cast, nickel-plated
Rated voltage (Dimensions)48 V AC
Sealing material (General)NBR
Status display (Dimensions)No
(Standards and Regulations)-20 °C ... 80 °C (cable, flexible installation)
eCl@ss 5.1 (Classifications)27060300
eCl@ss 6.0 (Classifications)27279200
eCl@ss 7.0 (Classifications)27279218
eCl@ss 8.0 (Classifications)27279218
eCl@ss 9.0 (Classifications)27060311
Material of grip body (General)TPU, hardly inflammable, self-extinguishing
Degree of pollution (Dimensions)3
Number of positions (Dimensions)4
Overvoltage category (Dimensions)II
Contact carrier material (General)TPU GF
Contact surface material (General)Ni/Au
Insulation resistance (Dimensions)≥ 100 MΩ
Rated current at 40°C (Dimensions)4 A
Length of cable (Key Commercial Data)2 m
Shielding (Standards and Regulations)Tinned copper braided shield
Cable type (Standards and Regulations)CAN Bus/DeviceNet
Attenuation (Standards and Regulations)≤ 22.9 dB/km (with 1 MHz)
Wire colors (Standards and Regulations)Red-black, blue-white
Acceleration (Standards and Regulations)3 m/s²
Cable weight (Standards and Regulations)90 kg/km
Halogen-free (Standards and Regulations)in accordance with DIN VDE 0472 part 815
Insertion/withdrawal cycles (Dimensions)≥ 100
UL AWM style (Standards and Regulations)21198 (80°C/300 V)
Overall twist (Standards and Regulations)2 pairs around a drain wire in the center to the core
Twisted pairs (Standards and Regulations)2 cores to the pair
Bending radius (Standards and Regulations)70 mm
Cable capacity (Standards and Regulations)nom. 40 nF/km (Data cable)
Wave impedance (Standards and Regulations)120 Ω ±10 % (with 1 MHz)
AWG signal line (Standards and Regulations)24
Cable structure (Standards and Regulations)2xAWG24/19+2xAWG22/19
Loop resistance (Standards and Regulations)≤ 181.80 Ω/km (Data cable)
Traversing path (Standards and Regulations)4.5 m
Traversing rate (Standards and Regulations)3 m/s
AWG power supply (Standards and Regulations)22
Flame resistance (Standards and Regulations)UL 1581, Sec. 1060 (FT-1)
Other resistance (Standards and Regulations)Low adhesion
Conductor material (Standards and Regulations)Tin-plated Cu litz wires
Flammability rating according to UL 94 (General)HB
Flammability rating according to UL 94 (Material)HB
Insulation resistance (Standards and Regulations)≥ 5 GΩ*km (Data cable)
External sheath, color (Standards and Regulations)violet RAL 4001
Nominal voltage, cable (Standards and Regulations)≤ 300 V (Peak value, not for high-power applications)
Outer sheath, material (Standards and Regulations)PUR
Test voltage Core/Core (Standards and Regulations)2000 V (50 Hz, 1 min.)
Type of pair shielding (Standards and Regulations)Plastic-coated aluminum foil, aluminum side outside
Conductor cross section (Standards and Regulations)2x 0.25 mm² (Data cable)
Optical shield covering (Standards and Regulations)80 %
Number of bending cycles (Standards and Regulations)5000000
Test voltage Core/Shield (Standards and Regulations)2000 V (50 Hz, 1 min.)
Cable type (abbreviation) (Standards and Regulations)920
External cable diameter D (Standards and Regulations)6.7 mm ±0,3 mm
Material conductor insulation (Standards and Regulations)Foamed PE (Data cable)
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 80 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations)19x 0.13 mm
Core diameter including insulation (Standards and Regulations)1.95 mm ±0.05 mm (Data cable)
Conductor structure, voltage supply (Standards and Regulations)19x 0.15 mm
Minimum bending radius, fixed installation (Standards and Regulations)5 x D
Minimum bending radius, flexible installation (Standards and Regulations)10 x D
Minimum bending radius, drag chain applications (Standards and Regulations)10 x D

Product Description

Bus system cable, 4-pole halogen-free, shielded, M12 straight connector, encoding: B, a M12 straight female, encoding: B, cable length: 2 m
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Bus system cable, 4-position, PUR halogen-free, violet RAL 4001, shielded, Plug straight M12, B-coded, on Socket straight M12, B-coded, cable length: 2 m

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide