Technical Specifications

ParameterValue
GTIN4055626901497
(Cable)No hazardous substances above threshold values
Orderkey1090408
(Drawings)
Packing unit1
ETIM 5.0 (eCl@ss)EC001855
ETIM 6.0 (eCl@ss)EC001855
ETIM 7.0 (eCl@ss)EC001855
China RoHS (Cable)Environmentally friendly use period: unlimited = EFUP-e
Custom tariff number85444290
(Ambient conditions)24 V DC
Contact material (General)CuSn
Length of cable (Drawings)5 m
Material, knurls (General)Zinc die-cast, nickel-plated
Sealing material (General)NBR
Coding (Ambient conditions)A - standard
(Standards and Regulations)≤ 60 °C (cable, drag chain applications)
eCl@ss 6.0 (Classifications)27279200
eCl@ss 7.0 (Classifications)27279218
eCl@ss 8.0 (Classifications)27279218
eCl@ss 9.0 (Classifications)27060311
Material of grip body (General)TPU, hardly inflammable, self-extinguishing
Contact carrier material (General)TPU GF
Contact surface material (General)Ni/Au
Rated voltage (Ambient conditions)24 V AC
Standards/specifications (Material)M12 connector IEC 61076-2-101
Status display (Ambient conditions)3 LEDs
Cable type (Standards and Regulations)PUR, halogen-free, highly flexible, welding-sputter resistant, orange
Wire colors (Standards and Regulations)brown, white, blue, black
Acceleration (Standards and Regulations)10 m/s²
Degree of pollution (Ambient conditions)3
Halogen-free (Standards and Regulations)in accordance with DIN VDE 0472 part 815
Number of positions (Ambient conditions)4
UL AWM style (Standards and Regulations)20549 (80°C/300 V)
Overall twist (Standards and Regulations)4 wires, twisted
Overvoltage category (Ambient conditions)II
Insulation resistance (Ambient conditions)≥ 100 MΩ
Standards/regulations (Ambient conditions)M12 connector IEC 61076-2-101
AWG signal line (Standards and Regulations)22
Rated current at 40°C (Ambient conditions)4 A
Traversing path (Standards and Regulations)10 m
Traversing rate (Standards and Regulations)3 m/s
Ambient temperature (operation) (Dimensions)-25 °C ... 90 °C (Plug / socket)
Flame resistance (Standards and Regulations)in acc. with UL FT-2
Other resistance (Standards and Regulations)hydrolysis and microbe resistant
Cable abbreviation (Standards and Regulations)LiF9Y11Y
Conductor material (Standards and Regulations)Bare Cu litz wires
Special properties (Standards and Regulations)Sheath resistant to welding beads, can be recycled, matt, without adhesion, wear-resistant, flame resistant and self-extinguishing
Conductor resistance (Standards and Regulations)approx. 57 Ω/km
Flammability rating according to UL 94 (General)HB
Insertion/withdrawal cycles (Ambient conditions)≥ 100
Flammability rating according to UL 94 (Material)HB
Insulation resistance (Standards and Regulations)≥ 20 MΩ*km
Protective circuit/component (Ambient conditions)unwired
External sheath, color (Standards and Regulations)orange RAL 2003
Nominal voltage, cable (Standards and Regulations)300 V (Peak value, not for high-power applications)
Outer sheath, material (Standards and Regulations)PUR
Test voltage Core/Core (Standards and Regulations)3000 V (Spark test)
Conductor cross section (Standards and Regulations)4x 0.34 mm² (Signal line)
Number of bending cycles (Standards and Regulations)5000000
Cable type (abbreviation) (Standards and Regulations)810
External cable diameter D (Standards and Regulations)6.4 mm ±0.1 mm
Material conductor insulation (Standards and Regulations)PP
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 80 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations)42x 0.10 mm
Core diameter including insulation (Standards and Regulations)1.55 mm ±0.05 mm (Signal line)
Dimensional drawingPlug, M12 x 1, straight, shielded (Drawings)
Minimum bending radius, fixed installation (Standards and Regulations)5 x D
Minimum bending radius, flexible installation (Standards and Regulations)10 x D
Minimum bending radius, drag chain applications (Standards and Regulations)10 x D
Circuit diagramContact assignment of the M12 plug and the M12 socket (Drawings)
Schematic diagramPin assignment M12 socket, 4-pos., A-coded, view female side (Drawings)

Product Description

Sensor/actuator cable, 4-pole, halogen-free, solder splash resistant, highly flexible, orange RAL 2003, M12 straight male connector, coding: A, to M12 angled connection female, coding: A, with 3 LEDs,
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Dimensional drawingPlug, M12 x 1, straight, shielded

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top