| Parameter | Value |
|---|---|
| GTIN | 4046356568654 |
| (Cable) | No hazardous substances above threshold values |
| Orderkey | 1454040 |
| Catalog page | Page 153 (C-4-2013) |
| Packing unit | 1 pc |
| (Dimensions) | IP69K |
| Country of origin | PL (Poland) |
| China RoHS (Cable) | Environmentally friendly use period: unlimited = EFUP-e |
| Custom tariff number | 85444290 |
| (Ambient conditions) | 250 V DC |
| Minimum order quantity | 10 pc |
| Contact material (General) | CuSn |
| Material, knurls (General) | Stainless steel |
| Sealing material (General) | FPM |
| Coding (Ambient conditions) | A - standard |
| Torque (Ambient conditions) | 0.4 Nm (M12 connector) |
| (Standards and Regulations) | -15 °C ... 105 °C (cable, flexible installation) |
| Material of grip body (General) | PP |
| Standard designation (Material) | M12 connector |
| Standards/regulations (Material) | IEC 61076-2-101 |
| Degree of protection (Dimensions) | IP65 |
| Contact carrier material (General) | PP |
| Contact surface material (General) | Ni/Au |
| Rated voltage (Ambient conditions) | 250 V AC |
| Status display (Ambient conditions) | No |
| Weight per Piece (excluding packing) | 101.700 g |
| Length of cable (Key Commercial Data) | 2 m |
| Cable type (Standards and Regulations) | PE-X black |
| Wire colors (Standards and Regulations) | brown, white, blue, black |
| Acceleration (Standards and Regulations) | 10 m/s² |
| Cable weight (Standards and Regulations) | 44 kg/km |
| Degree of pollution (Ambient conditions) | 3 |
| Halogen-free (Standards and Regulations) | in accordance with DIN VDE 0472 part 815 |
| Number of positions (Ambient conditions) | 4 |
| Overall twist (Standards and Regulations) | 4 wires, twisted |
| Overvoltage category (Ambient conditions) | II |
| Bending radius (Standards and Regulations) | 52 mm |
| Insulation resistance (Ambient conditions) | ≥ 100 MΩ |
| Standards/regulations (Ambient conditions) | M12 connector IEC 61076-2-101 |
| AWG signal line (Standards and Regulations) | 20 |
| Rated current at 40°C (Ambient conditions) | 4 A |
| Traversing path (Standards and Regulations) | 10 m |
| Traversing rate (Standards and Regulations) | 3 m/s |
| Ambient temperature (operation) (Dimensions) | -40 °C ... 105 °C (Plug / socket) |
| Flame resistance (Standards and Regulations) | according to DIN 60332-1-2 |
| Other resistance (Standards and Regulations) | UV resistant according to DIN VDE 0276-605 |
| Resistance to oil (Standards and Regulations) | in accordance with DIN EN 60811-2-1 |
| Cable abbreviation (Standards and Regulations) | Li2X2X |
| Conductor material (Standards and Regulations) | Bare Cu litz wires |
| Fume corrosiveness (Standards and Regulations) | according to IEC 60754 |
| Special properties (Standards and Regulations) | Irradiated |
| Test voltage, cable (Standards and Regulations) | ≥ 3000 V AC |
| Conductor resistance (Standards and Regulations) | ≤ 39 Ω/km (at 20 °C) |
| Flammability rating according to UL 94 (General) | V0 |
| Insertion/withdrawal cycles (Ambient conditions) | ≥ 100 |
| Flammability rating according to UL 94 (Material) | V0 |
| Insulation resistance (Standards and Regulations) | ≥ 100 MΩ*km (at 20 °C) |
| Protective circuit/component (Ambient conditions) | unwired |
| Thickness, insulation (Standards and Regulations) | approx. 0.3 mm (Core insulation) |
| Concentration of fumes (Standards and Regulations) | according to DIN EN 61034 |
| External sheath, color (Standards and Regulations) | black-gray RAL 7021 |
| Nominal voltage, cable (Standards and Regulations) | ≤ 300 V AC |
| Outer sheath, material (Standards and Regulations) | PE-X |
| Conductor cross section (Standards and Regulations) | 4x 0.5 mm² (Signal line) |
| Number of bending cycles (Standards and Regulations) | 2000000 |
| Cable type (abbreviation) (Standards and Regulations) | 28X |
| External cable diameter D (Standards and Regulations) | 5.2 mm ±0.2 mm |
| Material conductor insulation (Standards and Regulations) | PE-X |
| Length of twist, overall twist (Standards and Regulations) | 61.6 mm |
| Ambient temperature (operation) (Standards and Regulations) | -40 °C ... 105 °C (cable, fixed installation) |
| Conductor structure signal line (Standards and Regulations) | 28x 0.15 mm |
| Core diameter including insulation (Standards and Regulations) | 1.6 mm ±0.05 mm (Signal line) |
| Smallest bending radius, fixed installation (Standards and Regulations) | 26 mm |
| Smallest bending radius, movable installation (Standards and Regulations) | 52 mm |
Technical specifications and performance data