| Parameter | Value |
|---|---|
| 250 V DC | |
| Type | Plug straight M12 |
| Coding | A |
| Shielded | no |
| Cable type | PUR, halogen-free, highly flexible, welding-sputter resistant, orange [810] |
| Application | Standard |
| Coding type | A |
| Cable length | 1 m |
| Halogen-free | in accordance with DIN VDE 0472 part 815 |
| Product type | Sensor/actuator cable |
| UL AWM Style | 20549 (80°C/300 V) |
| Overall twist | 4 wires, twisted |
| Seal material | NBR |
| Status display | no |
| AWG signal line | 22 |
| Contact material | CuSn |
| Flame resistance | in acc. with UL FT-2 |
| Other resistance | hydrolysis and microbe resistant |
| Tightening torque | 0.4 Nm |
| Conductor material | Bare Cu litz wires |
| Nominal current IN | 4 A |
| Nominal voltage UN | 250 V AC |
| Single wire, color | brown, white, blue, black |
| Special properties | Sheath resistant to welding beads, can be recycled, matt, without adhesion, wear-resistant, flame resistant and self-extinguishing |
| Degree of pollution | 3 |
| Dimensional drawing | |
| Number of positions | 4 |
| Degree of protection | IP65 |
| No. of cable outlets | 1 |
| Overvoltage category | II |
| Standard designation | M12 connector |
| Insulation resistance | ≥ 20 MΩ*km |
| Material of grip body | TPU, hardly inflammable, self-extinguishing |
| External sheath, color | orange RAL 2003 |
| Nominal voltage, cable | 300 V (Peak value, not for high-power applications) |
| Outer sheath, material | PUR |
| Status display present | No |
| Test voltage Core/Core | 3000 V (Spark test) |
| Conductor cross section | 4x 0.34 mm² (Signal line) |
| External cable diameter | 6.40 mm ±0.1 mm |
| Contact carrier material | TPU GF |
| Contact surface material | Ni/Au |
| Material wire insulation | PP |
| Standards/specifications | IEC 61076-2-101 |
| Max. conductor resistance | approx. 57 Ω/km |
| Material for screw connection | Zinc die-cast, nickel-plated |
| Wire diameter incl. insulation | 1.55 mm ±0.05 mm (Signal line) |
| Ambient temperature (operation) | -40 °C ... 80 °C (cable, fixed installation) |
| Conductor structure signal line | 42x 0.10 mm |
| Dynamic load capacity (bending) | Max. bending cycles: 5000000, Bending radius: 10 x D, Traversing path: 10 m, Traversing rate: 3 m/s, Acceleration: 10 m/s², Ambient temperature: ≤ 60 °C |
| Flammability rating according to UL 94 | HB |
| Minimum bending radius, fixed installation | 5 x D |
| Smallest bending radius, fixed installation | 32 mm |
| Minimum bending radius, flexible installation | 10 x D |
| Smallest bending radius, movable installation | 64 mm |
Technical specifications and performance data