| Parameter | Value |
|---|---|
| 48 V DC | |
| Shielded | No |
| Feed rate | 3 m/s |
| Cable type | Halogen-free PUR black |
| Abbreviation | Li9Y11Y |
| Acceleration | 10 m/s² |
| Advance path | 10 m |
| Cable Weight | 51 kg/km |
| Cable length | 0.15 m |
| Codification | to |
| Construction | M12 Straight Connector |
| Line Section | 4x 0.75 mm² (signal conductor) |
| Product Type | Sensor/Actuator Cables |
| UL AWM Style | 20549 / 10152 (80°C/300 V) |
| Encoding Type | to |
| Total cabling | 4 longitudinally stranded conductors |
| Bending radius | 48 mm |
| Locking system | Clip Lock |
| Oil Resistance | according to DIN EN 60811-2-1, 168 h at 100 °C |
| AWG Signal Line | 18 |
| Gasket material | Silicone |
| Line Resistance | ≤ 26 Ω/km (at 20 °C) |
| Number of poles | 4 |
| Contact material | Cu Alloy |
| Dimension Scheme | |
| Flame Resistance | according to UL 758/1581 (horizontal) |
| Protection Index | IP67 |
| Special Features | flexible |
| Other resistances | resistant to hydrolysis and microbes |
| Outer Wrap, Color | greyish black RAL 7021 |
| Status Indication | No |
| Contact resistance | ≤ 8 mΩ |
| Grip body material | TPU |
| Nominal Current IN | 8 A |
| Nominal voltage UN | 48 V AC |
| Protection Circuit | Unplugged |
| Test Voltage Cable | ≥ 3000 V AC (Spark Test) |
| Absence of halogens | according to DIN VDE 0472 part 815 |
| Conductive Material | Naked Cu Conductor |
| Cable Outer Diameter | 5.7 mm ±0.15 mm |
| Outer Wrap, Material | PUR |
| Single Driver, Color | brown, blue, black, white |
| Insulation resistance | ≥ 100 MΩ |
| Nominal Voltage Cable | ≤ 300 V AC |
| Number of Cable Outlets | 1 |
| Contact Support Material | AP 6.6 |
| Number of bending cycles | 4000000 |
| Cable Type (abbreviation) | PUR |
| Material: Contact Surface | Nickel plated |
| Screw connection material | unavailable |
| Wall Thickness Insulation | ≥ 0.21 mm |
| Wall Thickness Outer Wrap | ≥ 0.38 mm |
| Line Insulation Resistance | ≥ 1 GΩ*km (at 20 °C) |
| Available Status Indication | No |
| Ambient Temperature (Service) | -25 °C ... 80 °C (Cable, movable arrangement) |
| Minimum bending radius, fixed | 5 x D |
| Material: Conductor Insulation | PP |
| Conductor Construction Signal Cable | 42x 0.15 mm |
| Conductor diameter incl. insulation | 1.69 mm ±0.05 mm (signal conductor) |
| Flammability class according to UL 94 | V2 |
| Minimum bending radius, flexibly positioned | 10 x D |
Technical specifications and performance data