Service time: Monday to Friday 9:00-18:00
SAC-4P-M 8MS/0,6-PUR/M 8FS 2NC - SAC-4P-M 8MS/0,6-PUR/M 8FS 2NC 1093778 PHOENIX CONTACT Sensor/actuator cable, 4-position, PUR halogen-free, ..
In Stock Hot Product

SAC-4P-M 8MS/0,6-PUR/M 8FS 2NC

SAC-4P-M 8MS/0,6-PUR/M 8FS 2NC 1093778 PHOENIX CONTACT Sensor/actuator cable, 4-position, PUR halogen-free, ..

$0.00USD
3361 in stock
Key Specifications
GTIN:4055626914954
Orderkey:1093778
(Drawings):
Packing unit:1
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626914954
Orderkey1093778
(Drawings)
Packing unit1
ETIM 6.0 (eCl@ss)EC001855
ETIM 7.0 (eCl@ss)EC001855
Custom tariff number85444290
(Ambient conditions)60 V DC
Contact material (General)CuSn
Length of cable (Drawings)0.6 m
Material, knurls (General)Zinc die-cast, nickel-plated
Sealing material (General)NBR
Coding (Ambient conditions)A - standard
(Standards and Regulations)-25 °C ... 80 °C (cable, flexible installation)
eCl@ss 9.0 (Classifications)27060311
Material of grip body (General)TPU, hardly inflammable, self-extinguishing
Contact carrier material (General)TPU GF
Contact surface material (General)Ni/Au
Rated voltage (Ambient conditions)48 V AC
Standards/specifications (Material)M8 connector IEC 61076-2-104
Status display (Ambient conditions)No
Cable type (Standards and Regulations)PUR halogen-free black
Wire colors (Standards and Regulations)brown, blue, black
Acceleration (Standards and Regulations)10 m/s²
Cable weight (Standards and Regulations)18 kg/km
Degree of pollution (Ambient conditions)3
Halogen-free (Standards and Regulations)in accordance with DIN VDE 0472 part 815
Number of positions (Ambient conditions)4
UL AWM style (Standards and Regulations)20549 / 10493 (80°C/300 V)
Overall twist (Standards and Regulations)3 wires, twisted
Overvoltage category (Ambient conditions)II
Bending radius (Standards and Regulations)44 mm
Insulation resistance (Ambient conditions)≥ 100 MΩ
Standards/regulations (Ambient conditions)M8 connector IEC 61076-2-104
AWG signal line (Standards and Regulations)24
Rated current at 40°C (Ambient conditions)4 A
Traversing path (Standards and Regulations)10 m
Traversing rate (Standards and Regulations)3 m/s
Ambient temperature (operation) (Dimensions)-25 °C ... 90 °C (Plug / socket)
Flame resistance (Standards and Regulations)in accordance with UL 758/1581 FT2
Other resistance (Standards and Regulations)hydrolysis and microbe resistant
Resistance to oil (Standards and Regulations)in accordance with DIN EN 60811-2-1
Cable abbreviation (Standards and Regulations)Li9Y11Y-HF
Conductor material (Standards and Regulations)Bare Cu litz wires
Special properties (Standards and Regulations)Flexible cable conduit capable
Test voltage, cable (Standards and Regulations)≥ 3000 V
Conductor resistance (Standards and Regulations)≤ 78 Ω/km (at 20 °C)
Flammability rating according to UL 94 (General)HB
Insertion/withdrawal cycles (Ambient conditions)≥ 100
Flammability rating according to UL 94 (Material)HB
Insulation resistance (Standards and Regulations)≥ 100 GΩ*km (at 20 °C)
Protective circuit/component (Ambient conditions)unwired
Thickness, insulation (Standards and Regulations)≥ 0.21 mm (Core insulation)
External sheath, color (Standards and Regulations)black-gray RAL 7021
Nominal voltage, cable (Standards and Regulations)≤ 300 V
Outer sheath thickness (Standards and Regulations)approx. 0.5 mm
Outer sheath, material (Standards and Regulations)PUR
Conductor cross section (Standards and Regulations)3x 0.25 mm²
Number of bending cycles (Standards and Regulations)10000000
Cable type (abbreviation) (Standards and Regulations)PUR
External cable diameter D (Standards and Regulations)3.6 mm ±0.15 mm
Material conductor insulation (Standards and Regulations)PP
Length of twist, overall twist (Standards and Regulations)40 mm
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 80 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations)32x 0.10 mm
Core diameter including insulation (Standards and Regulations)1.17 mm ±0.02 mm
Circuit diagramContact assignment of M8 plugs/sockets (Drawings)
Dimensional drawingM8 x 1 male plug, straight version (Drawings)
Smallest bending radius, fixed installation (Standards and Regulations)18 mm
Smallest bending radius, movable installation (Standards and Regulations)36 mm
Schematic diagramPin assignment M8 socket, 4-pos., view female side (Drawings)

Product Description

Sensor/actuator cable, 4-pole, halogen-free PUR, grayish black RAL 7021, Straight male connector M8, to Straight connection female M8, cable length: 0.6 m, Pin 2 not connected
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Dimensional drawingM8 x 1 male plug, straight version

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top