| Parameter | Value |
|---|---|
| 60 V DC | |
| Type | free cable end |
| Coding | A |
| Shielded | yes |
| Bus system | INTERBUS |
| Cable type | INTERBUS [950] |
| Application | Standard |
| Sensor type | INTERBUS |
| Cable length | 5 m |
| Cable weight | 41 kg/km |
| Product type | Data cable preassembled |
| Test voltage | 800 V |
| UL AWM Style | 20963 (80°C/30 V) |
| Overall twist | 2 pairs around a drain wire in the center to the core |
| Seal material | NBR |
| Twisted pairs | 2 cores to the pair |
| Status display | no |
| Wave impedance | 75 Ω ±10 Ω (Signal line) |
| AWG signal line | 26 |
| Contact material | CuSn |
| Conductor material | Tin-plated Cu litz wires |
| Nominal current IN | 4 A |
| Nominal voltage UN | 48 V AC |
| Single wire, color | red-blue, green-yellow |
| Conductor structure | 2xAWG26/19+2xAWG22/19 |
| Degree of pollution | 3 |
| Number of positions | 4 |
| Transmission medium | Copper |
| Degree of protection | IP65 |
| No. of cable outlets | 1 |
| Overvoltage category | II |
| Signal type/category | INTERBUS |
| Insulation resistance | ≥ 100 MΩ |
| Material of grip body | TPU, hardly inflammable, self-extinguishing |
| Thickness, insulation | 0.24 mm (Conductor insulation, signal line) |
| External sheath, color | black RAL 9005 |
| Nominal voltage, cable | ≤ 100 V |
| Outer sheath, material | PUR |
| Status display present | No |
| Test voltage Core/Core | 1000 V (50 Hz, 1 min.) |
| Type of pair shielding | Aluminum-lined polyester foil |
| Conductor cross section | 2x 0.14 mm² (Signal line) |
| External cable diameter | 5.20 mm ±0.2 mm |
| Optical shield covering | 85 % |
| Thickness, outer sheath | approx. 0.75 mm |
| Contact carrier material | TPU GF |
| Contact surface material | Ni/Au |
| Material wire insulation | PP |
| Test voltage Core/Shield | 1000.00 V (50 Hz, 1 min.) |
| Max. conductor resistance | ≤ 150 Ω/km (Signal line) |
| Material for screw connection | Zinc die-cast, nickel-plated |
| Wire diameter incl. insulation | 0.97 mm (Signal line) |
| Ambient temperature (operation) | -40 °C ... 80 °C (cable, fixed installation) |
| Conductor structure signal line | 19x 0.10 mm |
| Dynamic load capacity (bending) | Max. bending cycles: 1000000, Bending radius: 110 mm, Traversing path: 6 m, Traversing rate: 4 m/s, Acceleration: 4 m/s² |
| Flammability rating according to UL 94 | HB |
| Minimum bending radius, fixed installation | 5 x D |
| Smallest bending radius, fixed installation | 26 mm |
| Minimum bending radius, flexible installation | 7.5 x D |
| Smallest bending radius, movable installation | 39 mm |
| Contact Color (signal designation) Contact (optional) | 1 (Socket) RD (0.34 mm²) |