Key Specifications
GTIN:4046356568692
(Cable):No hazardous substances above threshold values
Orderkey:1454082
Catalog page:Page 153 (C-4-2013)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356568692
(Cable)No hazardous substances above threshold values
Orderkey1454082
Catalog pagePage 153 (C-4-2013)
Packing unit1 pc
(Dimensions)IP69K
Country of originPL (Poland)
China RoHS (Cable)Environmentally friendly use period: unlimited = EFUP-e
Custom tariff number85444290
(Ambient conditions)250 V DC
Contact material (General)CuSn
Material, knurls (General)Stainless steel
Sealing material (General)FPM
Coding (Ambient conditions)A - standard
Torque (Ambient conditions)0.4 Nm (M12 connector)
(Standards and Regulations)-15 °C ... 105 °C (cable, flexible installation)
Material of grip body (General)PP
Standard designation (Material)M12 connector
Standards/regulations (Material)IEC 61076-2-101
Degree of protection (Dimensions)IP65
Contact carrier material (General)PP
Contact surface material (General)Ni/Au
Rated voltage (Ambient conditions)250 V AC
Status display (Ambient conditions)No
Weight per Piece (excluding packing)232.800 g
Length of cable (Key Commercial Data)5 m
Cable type (Standards and Regulations)PE-X black
Wire colors (Standards and Regulations)brown, white, blue, black
Acceleration (Standards and Regulations)10 m/s²
Cable weight (Standards and Regulations)44 kg/km
Degree of pollution (Ambient conditions)3
Halogen-free (Standards and Regulations)in accordance with DIN VDE 0472 part 815
Number of positions (Ambient conditions)4
Overall twist (Standards and Regulations)4 wires, twisted
Overvoltage category (Ambient conditions)II
Bending radius (Standards and Regulations)52 mm
Insulation resistance (Ambient conditions)≥ 100 MΩ
Standards/regulations (Ambient conditions)M12 connector IEC 61076-2-101
AWG signal line (Standards and Regulations)20
Rated current at 40°C (Ambient conditions)4 A
Traversing path (Standards and Regulations)10 m
Traversing rate (Standards and Regulations)3 m/s
Ambient temperature (operation) (Dimensions)-40 °C ... 105 °C (Plug / socket)
Flame resistance (Standards and Regulations)according to DIN 60332-1-2
Other resistance (Standards and Regulations)UV resistant according to DIN VDE 0276-605
Resistance to oil (Standards and Regulations)in accordance with DIN EN 60811-2-1
Cable abbreviation (Standards and Regulations)Li2X2X
Conductor material (Standards and Regulations)Bare Cu litz wires
Fume corrosiveness (Standards and Regulations)according to IEC 60754
Special properties (Standards and Regulations)Irradiated
Test voltage, cable (Standards and Regulations)≥ 3000 V AC
Conductor resistance (Standards and Regulations)≤ 39 Ω/km (at 20 °C)
Flammability rating according to UL 94 (General)V0
Insertion/withdrawal cycles (Ambient conditions)≥ 100
Flammability rating according to UL 94 (Material)V0
Insulation resistance (Standards and Regulations)≥ 100 MΩ*km (at 20 °C)
Protective circuit/component (Ambient conditions)unwired
Thickness, insulation (Standards and Regulations)approx. 0.3 mm (Core insulation)
Concentration of fumes (Standards and Regulations)according to DIN EN 61034
External sheath, color (Standards and Regulations)black-gray RAL 7021
Nominal voltage, cable (Standards and Regulations)≤ 300 V AC
Outer sheath, material (Standards and Regulations)PE-X
Conductor cross section (Standards and Regulations)4x 0.5 mm² (Signal line)
Number of bending cycles (Standards and Regulations)2000000
Cable type (abbreviation) (Standards and Regulations)28X
External cable diameter D (Standards and Regulations)5.2 mm ±0.2 mm
Material conductor insulation (Standards and Regulations)PE-X
Length of twist, overall twist (Standards and Regulations)61.6 mm
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 105 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations)28x 0.15 mm
Core diameter including insulation (Standards and Regulations)1.6 mm ±0.05 mm (Signal line)
Smallest bending radius, fixed installation (Standards and Regulations)26 mm
Smallest bending radius, movable installation (Standards and Regulations)52 mm

Product Description

Sensor/Actuator Cable, 4-Pole, Halogen-Free PE-X, Grey-Black RAL 7021, Free Cable End, to Straight Connecting Female M12, Coding: A, Cable Length: 5 m, For Outdoor Applications, With Stainless Steel K
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified