Service time: Monday to Friday 9:00-18:00
SAC-4P-30,0-28X/M12FS SH OD - SAC-4P-30,0-28X/M12FS SH OD 1408855 PHOENIX CONTACT Sensor/actuator cable SAC-4P-30,0-28X/M12FS SH OD 1408855
In Stock Hot Product

SAC-4P-30,0-28X/M12FS SH OD

SAC-4P-30,0-28X/M12FS SH OD 1408855 PHOENIX CONTACT Sensor/actuator cable SAC-4P-30,0-28X/M12FS SH OD 1408855

$0.00USD
4869 in stock
Key Specifications
GTIN:4046356835015
(Cable):For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey:1408855
Packing unit:1
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356835015
(Cable)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey1408855
Packing unit1
(Dimensions)-40 °C ... 85 °C (On sudden changes in temperature (according to IEC 60512-11-4))
UNSPSC 11 (ETIM)31251501
ETIM 3.0 (eCl@ss)EC001855
ETIM 4.0 (eCl@ss)EC001855
ETIM 5.0 (eCl@ss)EC001855
ETIM 6.0 (eCl@ss)EC001855
ETIM 7.0 (eCl@ss)EC001855
China RoHS (Cable)Environmentally Friendly Use Period = 50
REACh SVHC (Cable)
UNSPSC 13.2 (ETIM)31251501
UNSPSC 6.01 (ETIM)31251501
UNSPSC 12.01 (ETIM)31251501
Custom tariff number85444290
UNSPSC 7.0901 (ETIM)31251501
(Ambient conditions)60 V DC
Contact material (General)CuSn
Material, knurls (General)Stainless steel
Sealing material (General)FPM
Coding (Ambient conditions)A - standard
(Standards and Regulations)-15 °C ... 105 °C (cable, flexible installation)
eCl@ss 4.0 (Classifications)27060306
eCl@ss 4.1 (Classifications)27060306
eCl@ss 5.0 (Classifications)27061801
eCl@ss 5.1 (Classifications)27061800
eCl@ss 6.0 (Classifications)27279200
eCl@ss 7.0 (Classifications)27279218
eCl@ss 8.0 (Classifications)27279218
eCl@ss 9.0 (Classifications)27060311
Material of grip body (General)PP
Standard designation (Material)M12 connector
Standards/regulations (Material)IEC 61076-2-101
Contact carrier material (General)PP
Contact surface material (General)Ni/Au
Rated voltage (Ambient conditions)48 V AC
Status display (Ambient conditions)No
Length of cable (Key Commercial Data)30 m
Shielding (Standards and Regulations)Braided copper wires
Cable type (Standards and Regulations)PE-X black
Wire colors (Standards and Regulations)brown, white, blue, black
Acceleration (Standards and Regulations)10 m/s²
Cable weight (Standards and Regulations)74 kg/km
Degree of pollution (Ambient conditions)3
Halogen-free (Standards and Regulations)in accordance with DIN VDE 0472 part 815
Number of positions (Ambient conditions)4
Overall twist (Standards and Regulations)4 wires, twisted
Bending radius (Standards and Regulations)68 mm
Cable capacity (Standards and Regulations)≤ 100 nF/km (Conductor-conductor, asymmetrical/touching)
Insulation resistance (Ambient conditions)≥ 100 MΩ
Standards/regulations (Ambient conditions)M12 connector IEC 61076-2-101
AWG signal line (Standards and Regulations)20
Rated current at 40°C (Ambient conditions)4 A
Traversing path (Standards and Regulations)10 m
Traversing rate (Standards and Regulations)3 m/s
Ambient temperature (operation) (Dimensions)-40 °C ... 105 °C (Plug / socket)
Flame resistance (Standards and Regulations)according to DIN 60332-1-2
Other resistance (Standards and Regulations)UV resistant according to DIN VDE 0276-605
Resistance to oil (Standards and Regulations)in accordance with DIN EN 60811-2-1
Cable abbreviation (Standards and Regulations)Li2X2X-C-Vl-2X
Conductor material (Standards and Regulations)Bare Cu litz wires
Special properties (Standards and Regulations)Irradiated
Test voltage, cable (Standards and Regulations)≥ 3000 V AC
Conductor inductance (Standards and Regulations)0.64 mH/km (at 1 kHz)
Conductor resistance (Standards and Regulations)≤ 39 Ω/km (at 20 °C)
Flammability rating according to UL 94 (General)V0
Flammability rating according to UL 94 (Material)V0
Insulation resistance (Standards and Regulations)≥ 100 MΩ*km (at 20 °C)
Protective circuit/component (Ambient conditions)unwired
Thickness, insulation (Standards and Regulations)approx. 0.3 mm (Core insulation)
External sheath, color (Standards and Regulations)black-gray RAL 7021
Material, inner sheath (Standards and Regulations)PE-X
Nominal voltage, cable (Standards and Regulations)≤ 300 V AC
Outer sheath, material (Standards and Regulations)PE-X
Conductor cross section (Standards and Regulations)4x 0.5 mm² (Signal line)
Optical shield covering (Standards and Regulations)85 %
Number of bending cycles (Standards and Regulations)1000000
Cable type (abbreviation) (Standards and Regulations)28X
External cable diameter D (Standards and Regulations)6.8 mm ±0.2 mm
Material conductor insulation (Standards and Regulations)PE-X
Length of twist, overall twist (Standards and Regulations)108.8 mm
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 105 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations)28x 0.15 mm
Core diameter including insulation (Standards and Regulations)1.6 mm ±0.05 mm (Signal line)
Smallest bending radius, fixed installation (Standards and Regulations)34 mm
Smallest bending radius, movable installation (Standards and Regulations)68 mm

Product Description

Sensor/actuator cable, 4-pole, halogen-free PE-X/PE-X, greyish black RAL 7021, shielded, free cable end, to straight female M12, coding: A, cable length: 30 m, for outdoor applications, with stainless
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Sensor/actuator cable, 4-position, PE-X/PE-X halogen-free, black-gray RAL 7021, shielded, cable length: 30 m, for outdoor applications, with high-grade steel knurl

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top