Key Specifications
GTIN:4046356892896
Orderkey:1410151
Packing unit:1
ETIM 5.0 (eCl@ss):EC001855
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356892896
Orderkey1410151
Packing unit1
ETIM 5.0 (eCl@ss)EC001855
ETIM 6.0 (eCl@ss)EC001855
ETIM 7.0 (eCl@ss)EC001855
UNSPSC 13.2 (ETIM)31251501
Custom tariff number85444290
(Ambient conditions)Material conformance FDA 21 CFR 177.2600
Contact material (General)CuSn
Material, knurls (General)Stainless steel
Sealing material (General)FKM
Coding (Ambient conditions)A - standard
Torque (Ambient conditions)0.4 Nm (M12 connector)
(Standards and Regulations)-25 °C ... 105 °C (cable, flexible installation)
eCl@ss 5.1 (Classifications)27061800
eCl@ss 6.0 (Classifications)27279200
eCl@ss 7.0 (Classifications)27279218
eCl@ss 8.0 (Classifications)27279218
eCl@ss 9.0 (Classifications)27060311
Material of grip body (General)PP
Standard designation (Material)Material conformance
Standards/regulations (Material)FDA 21 CFR 177.2600
Contact carrier material (General)PP
Contact surface material (General)Ni/Au
Rated voltage (Ambient conditions)48 V AC
Status display (Ambient conditions)No
Length of cable (Key Commercial Data)20 m
Shielding (Standards and Regulations)Braided copper wires
Cable type (Standards and Regulations)Halogen-free PP gray shielded
Wire colors (Standards and Regulations)brown, white, blue, black
Acceleration (Standards and Regulations)10 m/s²
Cable weight (Standards and Regulations)40 kg/km
Degree of pollution (Ambient conditions)3
Halogen-free (Standards and Regulations)in accordance with DIN VDE 0472 part 815
Number of positions (Ambient conditions)4
Overall twist (Standards and Regulations)4 wires, twisted
Overvoltage category (Ambient conditions)II
Insulation resistance (Ambient conditions)≥ 100 MΩ
Standards/regulations (Ambient conditions)M12 connector IEC 61076-2-101
AWG signal line (Standards and Regulations)22
Rated current at 40°C (Ambient conditions)4 A
Traversing path (Standards and Regulations)10 m
Traversing rate (Standards and Regulations)3 m/s
Ambient temperature (operation) (Dimensions)-40 °C ... 105 °C (Plug / socket)
Other resistance (Standards and Regulations)Resistant to cold bending and cold impacts According to DIN EN 60811-1-4 (-40 °C)
Cable abbreviation (Standards and Regulations)Li9YV1-C-V1-9Y
Conductor material (Standards and Regulations)Bare Cu litz wires
Special properties (Standards and Regulations)FDA compliant according to FDA 21 CFR 177.2600
Test voltage, cable (Standards and Regulations)≥ 3000 V AC (Spark test)
Conductor resistance (Standards and Regulations)58 Ω/km (at 20 °C)
Insertion/withdrawal cycles (Ambient conditions)≥ 100
Thickness, insulation (Standards and Regulations)≥ 0.21 mm (Core insulation)
External sheath, color (Standards and Regulations)gray RAL 7035
Nominal voltage, cable (Standards and Regulations)≤ 300 V AC
Outer sheath thickness (Standards and Regulations)approx. 0.8 mm
Outer sheath, material (Standards and Regulations)PP-EPDM
Conductor cross section (Standards and Regulations)4x 0.34 mm² (Signal line)
Optical shield covering (Standards and Regulations)85 %
Number of bending cycles (Standards and Regulations)2000000
Test voltage Core/Shield (Standards and Regulations)≥ 2000 V AC (for 60 s)
Cable type (abbreviation) (Standards and Regulations)600
External cable diameter D (Standards and Regulations)5.55 mm ±0.2 mm
Material conductor insulation (Standards and Regulations)PP
Length of twist, overall twist (Standards and Regulations)48 mm
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 105 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations)42x 0.10 mm
Core diameter including insulation (Standards and Regulations)1.27 mm ±0.02 mm (Signal line)
Minimum bending radius, fixed installation (Standards and Regulations)5 x D
Minimum bending radius, flexible installation (Standards and Regulations)10 x D
Minimum bending radius, drag chain applications (Standards and Regulations)10 x D

Product Description

Sensor/actuator cable, 4-pole, halogen-free PP-EPDM, grey RAL 7035, shielded, free cable end, to straight connection female M12, coding: A, cable length: 20 m, Hygienic design, with stainless steel kn
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Sensor/actuator cable, 4-position, PP-EPDM halogen-free, gray RAL 7035, shielded, free cable end, on Socket straight M12, A-coded, cable length: 20 m, Hygienic design, with high-grade steel knurl