Service time: Monday to Friday 9:00-18:00
SAC-4P-2-PUR/M12FS SHNC SH5 BK - SAC-4P-2-PUR/M12FS SHNC SH5 BK 1057744 PHOENIX CONTACT Sensor/actuator cable SAC-4P-2-PUR/M12FS SHNC SH5 BK ..
In Stock Hot Product

SAC-4P-2-PUR/M12FS SHNC SH5 BK

SAC-4P-2-PUR/M12FS SHNC SH5 BK 1057744 PHOENIX CONTACT Sensor/actuator cable SAC-4P-2-PUR/M12FS SHNC SH5 BK ..

$0.00USD
4008 in stock
Key Specifications
GTIN:4055626703787
(Cable):For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey:1057744
Packing unit:1
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626703787
(Cable)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey1057744
Packing unit1
UNSPSC 11 (ETIM)31251501
ETIM 2.0 (eCl@ss)EC000830
ETIM 3.0 (eCl@ss)EC001855
ETIM 4.0 (eCl@ss)EC001855
ETIM 5.0 (eCl@ss)EC001855
ETIM 6.0 (eCl@ss)EC001855
ETIM 7.0 (eCl@ss)EC001855
China RoHS (Cable)Environmentally Friendly Use Period = 50
UNSPSC 13.2 (ETIM)31251501
UNSPSC 6.01 (ETIM)31251501
UNSPSC 12.01 (ETIM)31251501
Custom tariff number85444290
UNSPSC 7.0901 (ETIM)31251501
(Ambient conditions)60 V DC
Contact material (General)CuSn
Material, knurls (General)Zinc die-cast, nickel-plated
Sealing material (General)NBR
Coding (Ambient conditions)A - standard
(Standards and Regulations)-25 °C ... 80 °C (cable, flexible installation)
eCl@ss 4.0 (Classifications)27060306
eCl@ss 4.1 (Classifications)27060306
eCl@ss 5.0 (Classifications)27061801
eCl@ss 5.1 (Classifications)27061801
eCl@ss 6.0 (Classifications)27279200
eCl@ss 7.0 (Classifications)27279218
eCl@ss 8.0 (Classifications)27279218
eCl@ss 9.0 (Classifications)27060311
Material of grip body (General)TPU, hardly inflammable, self-extinguishing
Contact carrier material (General)TPU GF
Contact surface material (General)Ni/Au
Rated voltage (Ambient conditions)48 V AC
Status display (Ambient conditions)No
Length of cable (Key Commercial Data)2 m
Shielding (Standards and Regulations)Tinned copper braided shield
Cable type (Standards and Regulations)PUR halogen-free black
Wire colors (Standards and Regulations)brown, white, blue, black
Acceleration (Standards and Regulations)10 m/s²
Cable weight (Standards and Regulations)46 kg/km
Degree of pollution (Ambient conditions)3
Halogen-free (Standards and Regulations)in accordance with DIN VDE 0472 part 815
Number of positions (Ambient conditions)4
UL AWM style (Standards and Regulations)20549 / 10493 (80°C/300 V)
Overall twist (Standards and Regulations)4 wires, twisted
Overvoltage category (Ambient conditions)II
Bending radius (Standards and Regulations)59 mm
Cable capacity (Standards and Regulations)≤ 80 pF/m (Conductor-Conductor)
Insulation resistance (Ambient conditions)≥ 100 MΩ
Wave impedance (Standards and Regulations)≥ 62 Ω (f = 10 MHz)
AWG signal line (Standards and Regulations)22
Rated current at 40°C (Ambient conditions)4 A
Traversing path (Standards and Regulations)10 m
Traversing rate (Standards and Regulations)3 m/s
Ambient temperature (operation) (Dimensions)-25 °C ... 90 °C (Plug / socket)
Flame resistance (Standards and Regulations)in acc. with UL FT-2
Other resistance (Standards and Regulations)Highly resistant to acids, alkaline solutions and solvents
Resistance to oil (Standards and Regulations)in accordance with DIN EN 60811-2-1
Cable abbreviation (Standards and Regulations)Li9Y-V1-C-V1-11Y
Conductor material (Standards and Regulations)Bare Cu litz wires
Special properties (Standards and Regulations)Flexible cable conduit capable
Test voltage, cable (Standards and Regulations)≥ 3000 V
Conductor inductance (Standards and Regulations)approx. 0.75 mH/km (f = 1 kHz)
Conductor resistance (Standards and Regulations)max. 58 Ω/km (at 20 °C)
Flammability rating according to UL 94 (General)HB
Insertion/withdrawal cycles (Ambient conditions)≥ 100
Flammability rating according to UL 94 (Material)HB
Insulation resistance (Standards and Regulations)≥ 100 GΩ*km (at 20 °C)
Thickness, insulation (Standards and Regulations)≥ 0.21 mm
External sheath, color (Standards and Regulations)black-gray RAL 7021
Nominal voltage, cable (Standards and Regulations)≤ 300 V
Outer sheath thickness (Standards and Regulations)approx. 1 mm
Outer sheath, material (Standards and Regulations)PUR
Conductor cross section (Standards and Regulations)4x 0.34 mm² (Signal line)
Optical shield covering (Standards and Regulations)85 %
Number of bending cycles (Standards and Regulations)2000000
Cable type (abbreviation) (Standards and Regulations)PUR
External cable diameter D (Standards and Regulations)5.9 mm ±0.2 mm
Material conductor insulation (Standards and Regulations)PP
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 80 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations)42x 0.10 mm
Core diameter including insulation (Standards and Regulations)1.27 mm ±0.02 mm (Signal line)
Stripping length of the free conductor end (Key Commercial Data)50 mm
Minimum bending radius, fixed installation (Standards and Regulations)5 x D
Smallest bending radius, fixed installation (Standards and Regulations)29.5 mm
Minimum bending radius, flexible installation (Standards and Regulations)10 x D
Smallest bending radius, movable installation (Standards and Regulations)59 mm
Minimum bending radius, drag chain applications (Standards and Regulations)10 x D

Product Description

Sensor/actuator cable, 4-pole, halogen-free PUR, greyish black RAL 7021, shielded, free cable end, to Straight connection female M12, coding: A, cable length: 2 m, Customer variant, Display to PIN5
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Sensor/actuator cable, 4-position, PUR halogen-free, black-gray RAL 7021, shielded, free cable end, on Socket straight M12, A-coded, cable length: 2 m, Customer version, Shield on PIN5

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top