| Parameter | Value |
|---|---|
| 1.10 mm (Outer cable sheath) | |
| Shielded | no |
| Cable type | PUR irradiated halogen-free yellow [160] |
| Cable length | 100 m |
| Cable weight | 57 kg/km |
| Product type | Cable by the meter |
| Test voltage | 2000 V (50 Hz, 5 minutes) |
| Overall twist | 4 wires, twisted |
| AWG signal line | 18 |
| Flame resistance | according to DIN VDE 0472 Part 804 |
| Conductor material | Bare Cu litz wires |
| Single wire, color | brown, white, blue, black |
| Special properties | Irradiated |
| Dimensional drawing | |
| Number of positions | 4 |
| Thickness, insulation | 0.25 mm (Core insulation) |
| External sheath, color | yellow |
| Nominal voltage, cable | 300 V AC |
| Outer sheath, material | PUR |
| Conductor cross section | 4x 0.75 mm² (Signal line) |
| External cable diameter | 6.20 mm ±0.2 mm |
| Material wire insulation | PE |
| Max. conductor resistance | ≤ 26 mΩ/m |
| Wire diameter incl. insulation | 1.6 mm ±0.1 mm (Signal line) |
| Ambient temperature (operation) | -50 °C ... 105 °C (cable, fixed installation) |
| Conductor structure signal line | 24x 0.21 mm |
| Dynamic load capacity (bending) | Max. bending cycles: 5000000, Bending radius: 10 x D, Traversing path: 10 m, Traversing rate: 3 m/s |
| Dynamic load capacity (torsion) | Torsion: ±360 °/m |
| Minimum bending radius, fixed installation | 3 x D |
| Smallest bending radius, fixed installation | 19 mm |
| Minimum bending radius, flexible installation | 12 x D |
| Smallest bending radius, movable installation | 75 mm |