Service time: Monday to Friday 9:00-18:00
SAC-4P-10,9-PUR/M12FSS PE SH - SAC-4P-10,9-PUR/M12FSS PE SH 1090820 PHOENIX CONTACT Power cable, 4-position, PUR halogen-free, orange RAL 2..
In Stock Hot Product

SAC-4P-10,9-PUR/M12FSS PE SH

SAC-4P-10,9-PUR/M12FSS PE SH 1090820 PHOENIX CONTACT Power cable, 4-position, PUR halogen-free, orange RAL 2..

$0.00USD
4613 in stock
Key Specifications
GTIN:4055626902203
(Cable):For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey:1090820
(Drawings):
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626902203
(Cable)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey1090820
(Drawings)
Packing unit1 pc
(Dimensions)IP67
Country of originDE (Germany)
ETIM 5.0 (eCl@ss)EC001855
ETIM 6.0 (eCl@ss)EC001855
ETIM 7.0 (eCl@ss)EC001855
China RoHS (Cable)Environmentally Friendly Use Period = 50
REACh SVHC (Cable)
Custom tariff number85444290
Minimum order quantity50 pc
Contact material (General)CuZn
Length of cable (Drawings)10.9 m
Material, knurls (General)Zinc die-cast, nickel-plated
Coding (Ambient conditions)S power
Torque (Ambient conditions)0.4 Nm (M12 connector)
(Standards and Regulations)-30 °C ... 90 °C (cable, flexible installation)
eCl@ss 8.0 (Classifications)27279218
eCl@ss 9.0 (Classifications)27060311
Material of grip body (General)PP
Degree of protection (Dimensions)IP65
Contact carrier material (General)PA
Contact surface material (General)Ni/Au
Rated voltage (Ambient conditions)690 V AC
Standards/specifications (Material)M12 connector IEC 61076-2-111
Status display (Ambient conditions)No
Weight per Piece (excluding packing)1,580.000 g
Shielding (Standards and Regulations)Tinned copper-braided shield, approx. 85% covering
Cable type (Standards and Regulations)PUR halogen-free orange shielded
Color handle area (Ambient conditions)black
Wire colors (Standards and Regulations)Black 1, black 2, black 3, green/yellow
Acceleration (Standards and Regulations)10 m/s²
Degree of pollution (Ambient conditions)3
Halogen-free (Standards and Regulations)according to VDE 0282-13 Appendix C
Number of positions (Ambient conditions)4
UL AWM style (Standards and Regulations)20234 / 10492 (80°C/1000 V)
Overall twist (Standards and Regulations)4 wires optimally twisted
Overvoltage category (Ambient conditions)III
Torsion force (Standards and Regulations)± 25 °/m
Insulation resistance (Ambient conditions)≥ 100 MΩ
Standards/regulations (Ambient conditions)M12 connector IEC 61076-2-111
Rated current at 40°C (Ambient conditions)12 A
Traversing path (Standards and Regulations)10 m
Traversing rate (Standards and Regulations)3 m/s
AWG power supply (Standards and Regulations)16
Ambient temperature (operation) (Dimensions)-25 °C ... 85 °C (Plug / socket)
Flame resistance (Standards and Regulations)according to EN 60332-1-2
Other resistance (Standards and Regulations)UV resistant
Resistance to oil (Standards and Regulations)in accordance with DIN EN 60811-2-1
Cable abbreviation (Standards and Regulations)9YSLC11Y-JZ
Conductor material (Standards and Regulations)Bare Cu litz wires
Test voltage, cable (Standards and Regulations)4260 V AC (5 min.)
Conductor resistance (Standards and Regulations)≤ 13.3 Ω/km (at 20 °C)
Flammability rating according to UL 94 (General)V0
Insertion/withdrawal cycles (Ambient conditions)> 100
Flammability rating according to UL 94 (Material)V0
Insulation resistance (Standards and Regulations)≥ 10 MΩ*km (at 20 °C)
Protective circuit/component (Ambient conditions)unwired
Thickness, insulation (Standards and Regulations)0.4 mm
External sheath, color (Standards and Regulations)orange RAL 2003
Nominal voltage, cable (Standards and Regulations)1000 V AC
Outer sheath thickness (Standards and Regulations)1.2 mm
Outer sheath, material (Standards and Regulations)PUR
Conductor cross section (Standards and Regulations)4x 1.5 mm²
Number of bending cycles (Standards and Regulations)4000000
Cable type (abbreviation) (Standards and Regulations)PUR
External cable diameter D (Standards and Regulations)9.7 mm ±0,3 mm
Dimensional drawingM12 x 1 socket, straight (Drawings)
Material conductor insulation (Standards and Regulations)PP
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 90 °C (cable, fixed installation)
Core diameter including insulation (Standards and Regulations)≤ 2.5 mm
Conductor structure, voltage supply (Standards and Regulations)78x 0.15 mm
Minimum bending radius, fixed installation (Standards and Regulations)5 x D
Minimum bending radius, flexible installation (Standards and Regulations)7.5 x D
Minimum bending radius, drag chain applications (Standards and Regulations)10 x D
Schematic diagramPin assignment of M12 socket, 4-pos., S-coded, socket side view (Drawings)

Product Description

Power cable, 4-pole halogen-free, shielded (Advanced Shielding Technology), free cable end, to straight female M12, coding: S, cable length: 10.9 m, for alternating current up to 12 A/690 V
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Dimensional drawingM12 x 1 socket, straight

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top