| Parameter | Value |
|---|---|
| IP67 | |
| Coding | A - standard |
| Torque | 0.4 Nm (M12 connector) |
| Cable type | PUR halogen-free black |
| Wire colors | brown, white, blue, black |
| Acceleration | 10 m/s² |
| Cable weight | 30 kg/km |
| Halogen-free | in accordance with DIN VDE 0472 part 815 |
| UL AWM style | 20549 / 10493 (80°C/300 V) |
| Overall twist | 4 wires, twisted |
| Rated voltage | 250 V |
| Bending radius | 47 mm |
| Status display | No |
| AWG signal line | 22 |
| Length of cable | 10 m |
| Traversing path | 10 m |
| Traversing rate | 3 m/s |
| Contact material | CuSn |
| Flame resistance | according to UL 758/1581 (horizontal) |
| Material, knurls | Zinc die-cast, nickel-plated |
| Other resistance | Highly resistant to acids, alkaline solutions and solvents |
| Pollution degree | 3 |
| Sealing material | NBR |
| Resistance to oil | in accordance with DIN EN 60811-2-1 |
| Cable abbreviation | Li9Y11Y-HF |
| Conductor material | Bare Cu litz wires |
| Special properties | Flexible cable conduit capable |
| Number of positions | 4 |
| Test voltage, cable | ≥ 3000 V |
| Conductor resistance | ≤ 58 Ω/km |
| Degree of protection | IP65 |
| Overvoltage category | II |
| Insulation resistance | ≥ 10 MΩ |
| Material of grip body | TPU, hardly inflammable, self-extinguishing |
| Standards/regulations | M12 connector IEC 61076-2-101 |
| Thickness, insulation | ≥ 0.21 mm |
| External sheath, color | black-gray RAL 7021 |
| Nominal voltage, cable | ≤ 300 V |
| Outer sheath thickness | approx. 0.8 mm |
| Outer sheath, material | PUR |
| Rated current at 40°C | 4 A |
| Conductor cross section | 4x 0.34 mm² |
| Contact carrier material | TPU GF |
| Contact surface material | Ni/Au |
| Number of bending cycles | 4000000 |
| Cable type (abbreviation) | PUR |
| External cable diameter D | 4.7 mm ±0.15 mm |
| Insertion/withdrawal cycles | ≥ 100 |
| Protective circuit/component | Unwired |
| Material conductor insulation | PP |
| Ambient temperature (operation) | -25 °C ... 90 °C (Plug / socket) |
| Conductor structure signal line | 42x 0.10 mm |
| Core diameter including insulation | 1.27 mm ±0.02 mm |
| Flammability rating according to UL 94 | HB |
| Minimum bending radius, fixed installation | 5 x D |
| Stripping length of the free conductor end | 50 mm |
| Smallest bending radius, fixed installation | 23.5 mm |
| Minimum bending radius, flexible installation | 10 x D |
| Smallest bending radius, movable installation | 47 mm |
| Minimum bending radius, drag chain applications | 10 x D |
Technical specifications and performance data
Installation and operation guide