| Parameter | Value |
|---|---|
| GTIN | Four trillion fifty five billion six hundred twenty six million four hundred fifty eight thousand seventy six |
| (Size) | 60 V DC |
| (Cable) | Any hazardous substances above the threshold values |
| Sales key | BF1CDD - |
| Pieces/pack. | 1 PCS |
| Encoding (Size) | B-coded |
| ETIM 6.0 (eCl@ss) | EC001855 |
| ETIM 7.0 (eCl@ss) | EC001855 |
| China RoHS (Cable) | Period for proper use: unlimited = EFUP-and |
| N. of poles (Size) | Four |
| Number customs tariff | Eighty five million four hundred forty four thousand two hundred ninety |
| Rating voltage (Size) | 48 V AC |
| eCl@ss 6.0 (Rankings) | Twenty seven million two hundred seventy nine thousand two hundred |
| eCl@ss 7.0 (Rankings) | Twenty seven million two hundred seventy nine thousand two hundred eighteen |
| eCl@ss 9.0 (Rankings) | Twenty seven million sixty thousand three hundred eleven |
| Nut material (General) | Zinc die-cast, nickel-plated |
| The code for the order | One million four hundred twenty six thousand three hundred nine |
| Pollution degree (Size) | Three |
| Material gasket (General) | NBR |
| Contact material (General) | CuSn |
| Material handles (General) | TPU, hardly inflammable, self-extinguishing |
| Overvoltage category (Size) | II |
| Signalling status of (Size) | No |
| The amount of minimum order | 50 PCS |
| Insulation resistance (Size) | ≥ 100 MΩ |
| Rated current at 40 ℃ (Size) | 4 To |
| (Regulations and requirements) | -20 °C ... 80 °C (cable, mobile installation) |
| Insert material latch (General) | TPU GF |
| Length. cable (Commercial data) | 0.6 m |
| Material surface contacts (General) | Ni/Au |
| Weight per piece (package included) | 58,000 g |
| Shielding (Regulations and requirements) | Wire braid tinned copper |
| Cable type (Regulations and requirements) | CAN BUS/DeviceNet |
| Color wire (Regulations and requirements) | red-black, blue-white |
| Attenuation (Regulations and requirements) | ≤ 22,9 dB/km (with 1 MHz) |
| Bend radius (Regulations and requirements) | 70 mm |
| Acceleration (Regulations and requirements) | 3 m/s2 |
| UL AWM Style (Regulations and requirements) | 21198 (80 °C / 300 V) |
| Capacity line (Regulations and requirements) | nom. 40 nF/km (data Line) |
| Class behaviour according to UL 94 (General) | HB |
| Class behaviour according to UL 94 (Material) | HB |
| Lay the entire (Regulations and requirements) | 2 pairs around a flexible conductor applied in the center of the soul |
| Signal line AWG (Regulations and requirements) | Twenty four |
| Structure cable (Regulations and requirements) | 2xAWG24/19+2xAWG22/19 |
| Flame resistance (Regulations and requirements) | UL 1581, Sec. 1060 (FT-1) |
| Positioning speed (Regulations and requirements) | 3 m/s |
| Twisting in pairs (Regulations and requirements) | 2-pair conductors |
| Supply voltage AWG (Regulations and requirements) | Twenty two |
| Cover screen optical (Regulations and requirements) | 80 % |
| Positioning movement (Regulations and requirements) | 4.5 m |
| The other resistance (Regulations and requirements) | non-adherent |
| Insulation resistance (Regulations and requirements) | ≥ 5 GΩ*km (data Line) |
| Cable outer diameter D (Regulations and requirements) | 6.7 mm ±0.3 mm |
| External sheath, color (Regulations and requirements) | purple RAL 4001 |
| Outer sheath, material (Regulations and requirements) | WHILE |
| Rated voltage of cable (Regulations and requirements) | ≤ 300 V (peak Value, not for strong current) |
| Resistance of the pair (Regulations and requirements) | ≤ 181,80 Ω/km (data Line) |
| Test voltage wire/wire (Regulations and requirements) | 2000 V (50 Hz, 1 min.) |
| Conductor cross section (Regulations and requirements) | 2x 0.25 mm2 (data Line) |
| The absence of halogens (Regulations and requirements) | according to DIN VDE 0472 Part 815 |
| The conductive material (Regulations and requirements) | Cu wire, tin-plated |
| The weight of the cable (Regulations and requirements) | 90 kg/km |
| Characteristic impedance (Regulations and requirements) | 120 Ω ±10 % (1 MHz) |
| Material insulation wire (Regulations and requirements) | PE foam (data Line) |
| Test voltage wire/shield (Regulations and requirements) | 2000 V (50 Hz, 1 min.) |
| Cable type (abbreviation) (Regulations and requirements) | Nine hundred twenty |
| Tree conductor signal line (Regulations and requirements) | 19x 0.13 mm |
| Type of shielding in pairs (Regulations and requirements) | Aluminium film plastic-coated, side, aluminum outside |
| Bend radius, minimum, fixed (Regulations and requirements) | 5 x D |
| Bend radius, minimum, flexible (Regulations and requirements) | 10 x D |
| Ambient temperature (operation) (Regulations and requirements) | -40 °C ... 80 °C (cable, fixed installation) |
| The number of cycles of bending (Regulations and requirements) | Five million |
| Structure conductor supply voltage (Regulations and requirements) | 19x 0.15 mm |
| Wire diameter including insulation (Regulations and requirements) | A 1.95 mm ±0.05 mm (data Line) |
| Bend radius, minimum, insert cable drag chains (Regulations and requirements) | 10 x D |
Technical specifications and performance data