Key Specifications
GTIN:4055626956169
Orderkey:1100833
(Drawings):
Packing unit:1
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626956169
Orderkey1100833
(Drawings)
Packing unit1
(Dimensions)IP67
Custom tariff number85444290
Contact material (General)CuZn
Length of cable (Drawings)0.5 m
Material, knurls (General)Zinc die-cast, nickel-plated
Coding (Ambient conditions)S power
Torque (Ambient conditions)0.4 Nm
(Standards and Regulations)-30 °C ... 80 °C (cable, flexible installation)
eCl@ss 9.0 (Classifications)27060311
Material of grip body (General)PP
Degree of protection (Dimensions)IP65
Contact carrier material (General)PA
Contact surface material (General)Ni/Au
Rated voltage (Ambient conditions)690 V AC
Standards/specifications (Material)M12 connector IEC 61076-2-111
Status display (Ambient conditions)No
Cable type (Standards and Regulations)PUR halogen-free black
Color handle area (Ambient conditions)black
Wire colors (Standards and Regulations)Black 1, black 2, black 3, green/yellow
Acceleration (Standards and Regulations)10 m/s²
Cable weight (Standards and Regulations)114 kg/km
Degree of pollution (Ambient conditions)3
Halogen-free (Standards and Regulations)in accordance with DIN VDE 0472 part 815
Number of positions (Ambient conditions)4
UL AWM style (Standards and Regulations)20234 / 10492 (80°C/1000 V)
Overall twist (Standards and Regulations)4 wires, twisted
Overvoltage category (Ambient conditions)III
Standards/regulations (Ambient conditions)M12 connector IEC 61076-2-111
DiagramCurrent carrying capacity (Drawings)
Rated current at 40°C (Ambient conditions)12 A
Traversing path (Standards and Regulations)10 m
Traversing rate (Standards and Regulations)3 m/s
AWG power supply (Standards and Regulations)16
Flame resistance (Standards and Regulations)According to UL 758/1581 (Cable Flame)
Other resistance (Standards and Regulations)Hydrolysis and microbe resistant as per VDE 0282 section 10
Resistance to oil (Standards and Regulations)According to DIN EN 60811-2-1, 168 h at 100°C
Cable abbreviation (Standards and Regulations)Li9YV1-11Y
Conductor material (Standards and Regulations)Bare Cu litz wires
Test voltage, cable (Standards and Regulations)≥ 10000 V AC (Spark test)
Conductor resistance (Standards and Regulations)≤ 13 Ω/km (at 20 °C)
Flammability rating according to UL 94 (General)V0
Insertion/withdrawal cycles (Ambient conditions)> 100
Flammability rating according to UL 94 (Material)V0
Insulation resistance (Standards and Regulations)≥ 1 GΩ*km (at 20 °C)
Protective circuit/component (Ambient conditions)unwired
Thickness, insulation (Standards and Regulations)≥ 0.36 mm
External sheath, color (Standards and Regulations)black-gray RAL 7021
Nominal voltage, cable (Standards and Regulations)≤ 1000 V AC
Outer sheath thickness (Standards and Regulations)approx. 1.3 mm
Outer sheath, material (Standards and Regulations)PUR
Conductor cross section (Standards and Regulations)4x 1.5 mm²
Number of bending cycles (Standards and Regulations)2000000
Cable type (abbreviation) (Standards and Regulations)PUR
External cable diameter D (Standards and Regulations)8.8 mm ±0.25 mm
Material conductor insulation (Standards and Regulations)PP
Length of twist, overall twist (Standards and Regulations)93 mm
Ambient temperature (operation) (Standards and Regulations)-50 °C ... 80 °C (cable, fixed installation)
Circuit diagramContact assignment of the M12 socket (Drawings)
Core diameter including insulation (Standards and Regulations)2.45 mm ±0.05 mm
Conductor structure, voltage supply (Standards and Regulations)78x 0.15 mm
Minimum bending radius, fixed installation (Standards and Regulations)5 x D
Minimum bending radius, flexible installation (Standards and Regulations)10 x D
Minimum bending radius, drag chain applications (Standards and Regulations)10 x D

Product Description

Power cable, 4-pole halogen-free, free cable end, to straight female M12, coding: S, cable length: 0.5 m, for alternating current up to 12 A/690 V
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

DiagramCurrent carrying capacity

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top