| Parameter | Value |
|---|---|
| GTIN | 4017918961176 |
| Note | Made to Order (non-returnable) |
| Orderkey | 1518795 |
| (Material) | -5 °C ... 80 °C (cable, flexible installation) |
| Catalog page | Page 38 (C-4-2013) |
| Packing unit | 1 pc |
| (Dimensions) | IP68 |
| Country of origin | PL (Poland) |
| Custom tariff number | 85444290 |
| (Ambient conditions) | 250 V DC |
| Cable type (Material) | PUR halogen-free black |
| Wire colors (Material) | brown, blue, black |
| Cable weight (Material) | 26 kg/km |
| Overall twist (Material) | 3 wires, twisted |
| Bending radius (Material) | 44 mm |
| AWG signal line (Material) | 22 |
| Contact material (General) | CuSn |
| Material, knurls (General) | Zinc die-cast, nickel-plated |
| Sealing material (General) | NBR |
| Traversing path (Material) | 10 m |
| Traversing rate (Material) | 3 m/s |
| Coding (Ambient conditions) | A - standard |
| Torque (Ambient conditions) | 0.4 Nm (M12 connector) |
| (Standards and Regulations) | No hazardous substances above threshold values |
| Standard designation (Cable) | M12 connector |
| Cable abbreviation (Material) | Li9Y11Y |
| Conductor material (Material) | Bare Cu litz wires |
| Standards/regulations (Cable) | IEC 61076-2-101 |
| Test voltage, cable (Material) | 3000 V |
| Conductor resistance (Material) | ≤ 58 Ω/m |
| Material of grip body (General) | TPU, hardly inflammable, self-extinguishing |
| Insulation resistance (Material) | ≥ 100 GΩ*km |
| Thickness, insulation (Material) | ≥ 0.21 mm (Core insulation) |
| Degree of protection (Dimensions) | IP65 |
| External sheath, color (Material) | black-gray RAL 7021 |
| Nominal voltage, cable (Material) | 300 V |
| Outer sheath, material (Material) | PUR |
| Conductor cross section (Material) | 0.34 mm² |
| Contact carrier material (General) | TPU GF |
| Contact surface material (General) | Ni/Au |
| External cable diameter (Material) | 4.40 mm |
| Rated voltage (Ambient conditions) | 250 V AC |
| Number of bending cycles (Material) | 4000000 |
| Standards/specifications (Material) | M12 connector IEC 61076-2-101 |
| Status display (Ambient conditions) | No |
| Weight per Piece (excluding packing) | 90.700 g |
| Length of cable (Key Commercial Data) | 3 m |
| China RoHS (Standards and Regulations) | Environmentally friendly use period: unlimited = EFUP-e |
| Degree of pollution (Ambient conditions) | 3 |
| Material conductor insulation (Material) | PP |
| Number of positions (Ambient conditions) | 3 |
| Overvoltage category (Ambient conditions) | II |
| Ambient temperature (operation) (Material) | -40 °C ... 80 °C (cable, fixed installation) |
| Conductor structure signal line (Material) | 42x 0.10 mm |
| Insulation resistance (Ambient conditions) | ≥ 100 MΩ |
| Standards/regulations (Ambient conditions) | M12 connector IEC 61076-2-101 |
| Rated current at 40°C (Ambient conditions) | 4 A |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 90 °C (Plug / socket) |
| Core diameter including insulation (Material) | 1.27 mm ±0.02 mm |
| Flammability rating according to UL 94 (Cable) | HB |
| Flammability rating according to UL 94 (General) | HB |
| Insertion/withdrawal cycles (Ambient conditions) | ≥ 100 |
| Protective circuit/component (Ambient conditions) | unwired |
| Smallest bending radius, movable installation (Material) | 44 mm |
Technical specifications and performance data