| Parameter | Value |
|---|---|
| GTIN | 4055626502144 |
| (Cable) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Orderkey | 1017756 |
| (General) | -25 °C ... 80 °C (cable, flexible installation) |
| Packing unit | 1 |
| (Dimensions) | 60 V DC |
| China RoHS (Cable) | Environmentally Friendly Use Period = 50 |
| REACh SVHC (Cable) | Lead 7439-92-1 |
| Shielding (General) | Braided copper wires |
| Cable type (General) | PUR halogen-free black |
| Custom tariff number | 85444290 |
| Wire colors (General) | brown, blue, black |
| Acceleration (General) | 10 m/s² |
| Cable weight (General) | 26 kg/km |
| Halogen-free (General) | in accordance with DIN VDE 0472 part 815 |
| UL AWM style (General) | 20549 |
| Overall twist (General) | 3 wires, twisted |
| Bending radius (General) | 50 mm |
| AWG signal line (General) | 24 |
| Traversing path (General) | 10 m |
| Traversing rate (General) | 3 m/s |
| Flame resistance (General) | in accordance with UL 758/1581 FT2 |
| Other resistance (General) | Highly resistant to acids, alkaline solutions and solvents |
| Rated voltage (Dimensions) | 48 V AC |
| Resistance to oil (General) | in accordance with DIN EN 60811-2-1 |
| Cable abbreviation (General) | Li9Y-V1-C-V1-11Y |
| Conductor material (General) | Bare Cu litz wires |
| Special properties (General) | Flexible cable conduit capable |
| Test voltage, cable (General) | 3000 V |
| Conductor resistance (General) | max. 79 Ω/km |
| Insulation resistance (General) | ≥ 100 GΩ*km |
| Thickness, insulation (General) | ≥ 0.21 mm (Core insulation) |
| External sheath, color (General) | black-gray RAL 7021 |
| Nominal voltage, cable (General) | 300 V |
| Number of positions (Dimensions) | 3 |
| Outer sheath, material (General) | PUR |
| Conductor cross section (General) | 3x 0.25 mm² (Signal line) |
| Optical shield covering (General) | 80 % |
| Number of bending cycles (General) | 10000000 |
| Cable type (abbreviation) (General) | PUR |
| External cable diameter D (General) | 4.35 mm ±0.2 mm |
| Length of cable (Key Commercial Data) | 0.65 m |
| Material conductor insulation (General) | PP |
| Ambient temperature (operation) (General) | -40 °C ... 80 °C (cable, fixed installation) |
| Conductor structure signal line (General) | 32x 0.10 mm |
| Core diameter including insulation (General) | 1.17 mm ±0.02 mm (Signal line) |
| Smallest bending radius, fixed installation (General) | 22 mm |
| Smallest bending radius, movable installation (General) | 44 mm |