| Parameter | Value |
|---|---|
| 60 V DC | |
| Shielded | no |
| Cable type | PUR halogen-free black [PUR] |
| Cable length | 3 m |
| Cable weight | 18 kg/km |
| Halogen-free | in accordance with DIN VDE 0472 part 815 |
| Product type | Distributor with cable |
| Test voltage | ≥ 3000 V |
| UL AWM Style | 20549 / 10493 (80°C/300 V) |
| Overall twist | 3 wires, twisted |
| AWG signal line | 24 |
| Flame resistance | in accordance with UL 758/1581 FT2 |
| Other resistance | hydrolysis and microbe resistant |
| Resistance to oil | in accordance with DIN EN 60811-2-1 |
| Conductor material | Bare Cu litz wires |
| Nominal voltage UN | 48 V AC |
| Single wire, color | brown, blue, black |
| Special properties | Flexible cable conduit capable |
| Dimensional drawing | |
| Max. bending cycles | 10000000 |
| Number of positions | 3 |
| Insulation resistance | ≥ 100 GΩ*km (at 20 °C) |
| Thickness, insulation | ≥ 0.21 mm (Core insulation) |
| External sheath, color | black-gray RAL 7021 |
| Nominal voltage, cable | ≤ 300 V |
| Outer sheath, material | PUR |
| Conductor cross section | 3x 0.25 mm² (Signal line) |
| External cable diameter | 3.6 mm ±0.15 mm |
| Thickness, outer sheath | approx. 0.5 mm |
| Material wire insulation | PP |
| Max. conductor resistance | ≤ 78 Ω/km (at 20 °C) |
| Length of twist, overall twist | 40 mm |
| Wire diameter incl. insulation | 1.17 mm ±0.02 mm |
| Ambient temperature (operation) | -40 °C ... 80 °C (cable, fixed installation) |
| Conductor structure signal line | 32x 0.10 mm |
| Smallest bending radius, fixed installation | 18 mm |
| Smallest bending radius, movable installation | 36 mm |
Technical specifications and performance data
Installation and operation guide