Service time: Monday to Friday 9:00-18:00
SAC-3P-M8MS/0,15PUR/BI-1L-Z180 - SAC-3P-M8MS/0,15PUR/BI-1L-Z180 1420747 PHOENIX CONTACT Sensor/actuator cable SAC-3P-M8MS/0,15PUR/BI-1L-Z180 ..
In Stock Hot Product

SAC-3P-M8MS/0,15PUR/BI-1L-Z180

SAC-3P-M8MS/0,15PUR/BI-1L-Z180 1420747 PHOENIX CONTACT Sensor/actuator cable SAC-3P-M8MS/0,15PUR/BI-1L-Z180 ..

$0.00USD
3697 in stock
Key Specifications
GTIN:4055626233956
(Cable):For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey:1420747
Packing unit:1
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626233956
(Cable)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey1420747
Packing unit1
ETIM 5.0 (eCl@ss)EC001855
ETIM 6.0 (eCl@ss)EC001855
ETIM 7.0 (eCl@ss)EC001855
China RoHS (Cable)Environmentally Friendly Use Period = 50
REACh SVHC (Cable)
UNSPSC 13.2 (ETIM)31251501
Custom tariff number85444290
(Ambient conditions)Valve connector EN 175301-803
Contact material (General)CuSn
Material, knurls (General)Zinc die-cast, nickel-plated
Sealing material (General)TPU (Seal molded)
Coding (Ambient conditions)A - standard
(Standards and Regulations)-25 °C ... 80 °C (cable, flexible installation)
eCl@ss 6.0 (Classifications)27279200
eCl@ss 7.0 (Classifications)27279218
eCl@ss 8.0 (Classifications)27279218
eCl@ss 9.0 (Classifications)27060311
Material of grip body (General)TPU, hardly inflammable, self-extinguishing
Standard designation (Material)Valve connector
Standards/regulations (Material)EN 175301-803
Contact carrier material (General)TPU GF
Contact surface material (General)Ni/Au
Rated voltage (Ambient conditions)24 V AC
Status display (Ambient conditions)1 LED
Length of cable (Key Commercial Data)0.15 m
Material housing valve plug (General)TPU
Valve plug contact material (General)CuSn
Cable type (Standards and Regulations)PUR halogen-free black
Wire colors (Standards and Regulations)brown, blue, black
Acceleration (Standards and Regulations)10 m/s²
Cable weight (Standards and Regulations)23 kg/km
Degree of pollution (Ambient conditions)3
Halogen-free (Standards and Regulations)in accordance with DIN VDE 0472 part 815
Number of positions (Ambient conditions)3
UL AWM style (Standards and Regulations)20549
Overall twist (Standards and Regulations)3 wires, twisted
Overvoltage category (Ambient conditions)III
Bending radius (Standards and Regulations)44 mm
Insulation resistance (Ambient conditions)≥ 100 MΩ
Standards/regulations (Ambient conditions)M8 connector IEC 61076-2-104
AWG signal line (Standards and Regulations)22
Rated current at 40°C (Ambient conditions)4 A
Traversing path (Standards and Regulations)10 m
Traversing rate (Standards and Regulations)3 m/s
Ambient temperature (operation) (Dimensions)-20 °C ... 85 °C (valve plug)
Flame resistance (Standards and Regulations)in accordance with UL 758/1581 FT2
Other resistance (Standards and Regulations)Highly resistant to acids, alkaline solutions and solvents
Valve plug contact insert material (General)PA 6.6
Resistance to oil (Standards and Regulations)in accordance with DIN EN 60811-2-1
Valve plug contact surface material (General)Sn
Cable abbreviation (Standards and Regulations)Li9Y11Y
Conductor material (Standards and Regulations)Bare Cu litz wires
Special properties (Standards and Regulations)Flexible cable conduit capable
Test voltage, cable (Standards and Regulations)≥ 3000 V
Conductor resistance (Standards and Regulations)max. 58 Ω/km (at 20 °C)
Flammability rating according to UL 94 (General)HB
Flammability rating according to UL 94 (Material)HB
Insulation resistance (Standards and Regulations)≥ 100 GΩ*km (at 20 °C)
Thickness, insulation (Standards and Regulations)≥ 0.21 mm (Core insulation)
External sheath, color (Standards and Regulations)black-gray RAL 7021
Nominal voltage, cable (Standards and Regulations)≤ 300 V
Outer sheath, material (Standards and Regulations)PUR
Conductor cross section (Standards and Regulations)3x 0.34 mm² (Signal line)
Number of bending cycles (Standards and Regulations)10000000
Cable type (abbreviation) (Standards and Regulations)PUR
External cable diameter D (Standards and Regulations)3.85 mm ±0.15 mm
Material conductor insulation (Standards and Regulations)PP
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 80 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations)42x 0.10 mm
Core diameter including insulation (Standards and Regulations)1.27 mm ±0.02 mm (Signal line)
Smallest bending radius, fixed installation (Standards and Regulations)19 mm
Smallest bending radius, movable installation (Standards and Regulations)38 mm

Product Description

Sensor/actuator cable, 3-pole, halogen-free PUR, grayish black RAL 7021, Straight M8 connector, coding: A, a BI valve connectors (11 mm), with 1 LED, Circuit: Z diode, cable length: 0.15 m
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Sensor/actuator cable, 3-position, PUR halogen-free, black-gray RAL 7021, Plug straight M8, A-coded, on Valve connector BI (11 mm), with 1 LED, connected with Z diode, cable length: 0.15 m

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top