

| Parameter | Value |
|---|---|
| GTIN | 4055626129426 |
| Orderkey | 1417945 |
| Packing unit | 1 |
| (Dimensions) | 60 V DC |
| ETIM 5.0 (eCl@ss) | EC001855 |
| ETIM 6.0 (eCl@ss) | EC001855 |
| ETIM 7.0 (eCl@ss) | EC001855 |
| UNSPSC 13.2 (ETIM) | 31251501 |
| Coding (Dimensions) | A - standard |
| Custom tariff number | 85444290 |
| Contact material (General) | CuSn |
| Material, knurls (General) | Zinc die-cast, nickel-plated |
| Rated voltage (Dimensions) | 48 V AC |
| Sealing material (General) | NBR |
| Status display (Dimensions) | No |
| (Standards and Regulations) | -25 °C ... 80 °C (cable, flexible installation) |
| eCl@ss 5.1 (Classifications) | 27061801 |
| eCl@ss 6.0 (Classifications) | 27279200 |
| eCl@ss 7.0 (Classifications) | 27279218 |
| eCl@ss 8.0 (Classifications) | 27279218 |
| eCl@ss 9.0 (Classifications) | 27060311 |
| Material of grip body (General) | TPU, hardly inflammable, self-extinguishing |
| Degree of pollution (Dimensions) | 3 |
| Number of positions (Dimensions) | 3 |
| Overvoltage category (Dimensions) | II |
| Contact carrier material (General) | TPU GF |
| Contact surface material (General) | Ni/Au |
| Rated current at 40°C (Dimensions) | 4 A |
| Length of cable (Key Commercial Data) | 1.6 m |
| Cable type (Standards and Regulations) | PUR halogen-free black |
| Wire colors (Standards and Regulations) | brown, blue, black |
| Acceleration (Standards and Regulations) | 10 m/s² |
| Cable weight (Standards and Regulations) | 23 kg/km |
| Halogen-free (Standards and Regulations) | in accordance with DIN VDE 0472 part 815 |
| UL AWM style (Standards and Regulations) | 20549 |
| Overall twist (Standards and Regulations) | 3 wires, twisted |
| Bending radius (Standards and Regulations) | 44 mm |
| AWG signal line (Standards and Regulations) | 22 |
| Traversing path (Standards and Regulations) | 10 m |
| Traversing rate (Standards and Regulations) | 3 m/s |
| Flame resistance (Standards and Regulations) | in accordance with UL 758/1581 FT2 |
| Other resistance (Standards and Regulations) | Highly resistant to acids, alkaline solutions and solvents |
| Resistance to oil (Standards and Regulations) | in accordance with DIN EN 60811-2-1 |
| Cable abbreviation (Standards and Regulations) | Li9Y11Y |
| Conductor material (Standards and Regulations) | Bare Cu litz wires |
| Special properties (Standards and Regulations) | Flexible cable conduit capable |
| Test voltage, cable (Standards and Regulations) | ≥ 3000 V |
| Conductor resistance (Standards and Regulations) | max. 58 Ω/km (at 20 °C) |
| Flammability rating according to UL 94 (General) | HB |
| Flammability rating according to UL 94 (Material) | HB |
| Insulation resistance (Standards and Regulations) | ≥ 100 GΩ*km (at 20 °C) |
| Thickness, insulation (Standards and Regulations) | ≥ 0.21 mm (Core insulation) |
| External sheath, color (Standards and Regulations) | black-gray RAL 7021 |
| Nominal voltage, cable (Standards and Regulations) | ≤ 300 V |
| Outer sheath, material (Standards and Regulations) | PUR |
| Conductor cross section (Standards and Regulations) | 3x 0.34 mm² (Signal line) |
| Number of bending cycles (Standards and Regulations) | 10000000 |
| Cable type (abbreviation) (Standards and Regulations) | PUR |
| External cable diameter D (Standards and Regulations) | 3.85 mm ±0.15 mm |
| Material conductor insulation (Standards and Regulations) | PP |
| Ambient temperature (operation) (Standards and Regulations) | -40 °C ... 80 °C (cable, fixed installation) |
| Conductor structure signal line (Standards and Regulations) | 42x 0.10 mm |
| Core diameter including insulation (Standards and Regulations) | 1.27 mm ±0.02 mm (Signal line) |
| Smallest bending radius, fixed installation (Standards and Regulations) | 19 mm |
| Smallest bending radius, movable installation (Standards and Regulations) | 38 mm |
Technical specifications and performance data
Installation and operation guide