| Parameter | Value |
|---|---|
| GTIN | 4055626822099 |
| Orderkey | 1084047 |
| (General) | -5 °C ... 80 °C (cable, flexible installation) |
| (Drawings) | |
| Packing unit | 1 |
| (Dimensions) | IP67 |
| Cable type (General) | PUR POWER 0.75 mm² black |
| Custom tariff number | 85444290 |
| (Ambient conditions) | 250 V DC |
| Wire colors (General) | brown, white, blue, black |
| Acceleration (General) | 5 m/s² |
| Cable weight (General) | 57 kg/km |
| UL AWM style (General) | 20549 / 1061 (80°C/300 V) |
| Overall twist (General) | 4 wires, twisted |
| Bending radius (General) | 59 mm |
| AWG signal line (General) | 18 |
| Traversing path (General) | 5 m |
| Traversing rate (General) | 3 m/s |
| Flame resistance (General) | according to UL 758/1581 (horizontal) |
| Length of cable (Drawings) | 2.4 m |
| Other resistance (General) | hydrolysis and microbe resistant |
| Resistance to oil (General) | According to DIN EN 60811-2-1, 168 h at 100°C |
| Torque (Ambient conditions) | 0.4 Nm |
| Cable abbreviation (General) | LiY11Y |
| Conductor material (General) | Bare Cu litz wires |
| eCl@ss 9.0 (Classifications) | 27060311 |
| Test voltage, cable (General) | ≥ 3000 V |
| Conductor resistance (General) | max. 26 Ω/km (at 20 °C) |
| Insulation resistance (General) | ≥ 1 MΩ*km (at 20 °C) |
| Thickness, insulation (General) | ≥ 0.23 mm (Core insulation) |
| External sheath, color (General) | black-gray RAL 7021 |
| Nominal voltage, cable (General) | ≤ 300 V |
| Outer sheath, material (General) | PUR |
| Conductor cross section (General) | 4x 0.75 mm² (power line) |
| Degree of protection (Dimensions) | IP65 |
| Number of bending cycles (General) | 2000000 |
| Rated voltage (Ambient conditions) | 250 V AC |
| Cable type (abbreviation) (General) | 186 |
| External cable diameter D (General) | 5.9 mm ±0.15 mm |
| Material conductor insulation (General) | PVC |
| Degree of pollution (Ambient conditions) | 3 |
| Number of positions (Ambient conditions) | 3 |
| Ambient temperature (operation) (General) | -25 °C ... 80 °C (cable, fixed installation) |
| Conductor structure signal line (General) | 42x 0.15 mm |
| Overvoltage category (Ambient conditions) | II |
| Rated current at 40°C (Ambient conditions) | 4 A |
| Core diameter including insulation (General) | 1.75 mm ±0.05 mm |
| Minimum bending radius, fixed installation (General) | 5 x D |
| Minimum bending radius, flexible installation (General) | 10 x D |
| Smallest bending radius, movable installation (General) | 59 mm |
Technical specifications and performance data