| Parameter | Value |
|---|---|
| 60 V DC | |
| Type | Plug straight M12 |
| Coding | A |
| General | For applications in circuits of intrinsic safety protection type "i". Electrical values following EN 60079-14. |
| Material | CuSn (Contact) |
| Shielded | yes |
| Bus system | PROFIBUS PA |
| Cable type | Fieldbus FOUNDATION/PROFIBUS PA, blue [961] |
| Application | Process technology |
| Coding type | A (Standard) |
| Sensor type | PROFIBUS PA |
| Cable length | 0.5 m |
| Cable weight | 56.552 kg/km |
| Product type | Data cable preassembled |
| Signal speed | 0.66 c |
| Overall twist | One pair with one drain wire and fillers for core |
| Seal material | NBR |
| Twisted pairs | 2 cores to the pair |
| Cable capacity | 147 pF/m (at 1 kHz, core/shield) |
| Status display | no |
| AWG signal line | 18 |
| Cable impedance | 100 Ω ±20 % (At 31.25 kHz) |
| Flame resistance | UL 1685 (CSA FT 4) |
| Tensile strength | 260 N |
| Conductor material | Tin-plated Cu litz wires |
| Nominal current IN | 4 A |
| Nominal voltage UN | 48 V AC |
| Shield attenuation | 3.00 dB/km (at 39 kHz) |
| Single wire, color | blue, orange |
| Special properties | UL standards PLTC-ER and ITC |
| Conductor structure | 2xAWG18/7 + 1xAWG20/7 |
| Degree of pollution | 3 |
| Dimensional drawing | |
| Number of positions | 3 |
| Transmission medium | Copper |
| Working capacitance | 78 nF (at 1 kHz) |
| Degree of protection | IP65 |
| No. of cable outlets | 1 |
| Overvoltage category | II |
| Signal type/category | PROFIBUS PA, 31.25 kbps |
| Thickness, insulation | 0.50 mm |
| External sheath, color | blue RAL 5015 |
| Nominal voltage, cable | 300 V |
| Outer sheath, material | PVC |
| Status display present | No |
| Conductor cross section | 2x 0.75 mm² (Signal line) |
| External cable diameter | 7.50 mm ±0.25 mm |
| Optical shield covering | 100 % |
| Thickness, outer sheath | 1.00 mm |
| Material wire insulation | PO (Signal line) |
| Max. conductor resistance | ≤ 19.35 Ω/km (Signal line) |
| Insertion/withdrawal cycles | ≥ 100 |
| Wire diameter incl. insulation | 2.24 mm ±0.05 mm |
| Ambient temperature (operation) | -25 °C ... 90 °C |
| Conductor structure signal line | 7x 0.40 mm |
| Flammability rating according to UL 94 | HB |
| Smallest bending radius, fixed installation | 75 mm |
| Contact Color (signal designation) Contact (optional) | 1 (Plug) OG (DATA+) 1 (Socket) |
Technical specifications and performance data
Installation and operation guide