Service time: Monday to Friday 9:00-18:00
SAC-3P-M 8MS/ 4,5-PUR/M 8FR - SAC-3P-M 8MS/ 4,5-PUR/M 8FR 1085911 PHOENIX CONTACT Sensor/actuator cable, 3-position, PUR halogen-free, bla..
In Stock Hot Product

SAC-3P-M 8MS/ 4,5-PUR/M 8FR

SAC-3P-M 8MS/ 4,5-PUR/M 8FR 1085911 PHOENIX CONTACT Sensor/actuator cable, 3-position, PUR halogen-free, bla..

$0.00USD
4241 in stock
Key Specifications
GTIN:4055626876832
(Cable):For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey:1085911
(Drawings):
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626876832
(Cable)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey1085911
(Drawings)
Packing unit1
ETIM 6.0 (eCl@ss)EC001855
ETIM 7.0 (eCl@ss)EC001855
China RoHS (Cable)Environmentally Friendly Use Period = 50
REACh SVHC (Cable)
Custom tariff number85444290
(Ambient conditions)60 V DC
Contact material (General)CuSn
Length of cable (Drawings)4.5 m
Material, knurls (General)Zinc die-cast, nickel-plated
Sealing material (General)NBR
Coding (Ambient conditions)A - standard
(Standards and Regulations)-25 °C ... 80 °C (cable, flexible installation)
eCl@ss 6.0 (Classifications)27279200
eCl@ss 7.0 (Classifications)27279218
eCl@ss 9.0 (Classifications)27060311
Material of grip body (General)TPU, hardly inflammable, self-extinguishing
Contact carrier material (General)TPU GF
Contact surface material (General)Ni/Au
Rated voltage (Ambient conditions)48 V AC
Standards/specifications (Material)M8 connector IEC 61076-2-104
Status display (Ambient conditions)No
Cable type (Standards and Regulations)PUR halogen-free black
Wire colors (Standards and Regulations)brown, blue, black
Acceleration (Standards and Regulations)10 m/s²
Cable weight (Standards and Regulations)18 kg/km
Degree of pollution (Ambient conditions)3
Halogen-free (Standards and Regulations)in accordance with DIN VDE 0472 part 815
Number of positions (Ambient conditions)3
UL AWM style (Standards and Regulations)20549 / 10493 (80°C/300 V)
Overall twist (Standards and Regulations)3 wires, twisted
Overvoltage category (Ambient conditions)II
Bending radius (Standards and Regulations)44 mm
Insulation resistance (Ambient conditions)≥ 100 MΩ
Standards/regulations (Ambient conditions)M8 connector IEC 61076-2-104
AWG signal line (Standards and Regulations)24
Rated current at 40°C (Ambient conditions)4 A
Traversing path (Standards and Regulations)10 m
Traversing rate (Standards and Regulations)3 m/s
Ambient temperature (operation) (Dimensions)-25 °C ... 90 °C (Plug / socket)
Flame resistance (Standards and Regulations)in accordance with UL 758/1581 FT2
Other resistance (Standards and Regulations)hydrolysis and microbe resistant
Resistance to oil (Standards and Regulations)in accordance with DIN EN 60811-2-1
Cable abbreviation (Standards and Regulations)Li9Y11Y-HF
Conductor material (Standards and Regulations)Bare Cu litz wires
Special properties (Standards and Regulations)Flexible cable conduit capable
Test voltage, cable (Standards and Regulations)≥ 3000 V
Conductor resistance (Standards and Regulations)≤ 78 Ω/km (at 20 °C)
Flammability rating according to UL 94 (General)HB
Insertion/withdrawal cycles (Ambient conditions)≥ 100
Flammability rating according to UL 94 (Material)HB
Insulation resistance (Standards and Regulations)≥ 100 GΩ*km (at 20 °C)
Protective circuit/component (Ambient conditions)unwired
Thickness, insulation (Standards and Regulations)≥ 0.21 mm (Core insulation)
External sheath, color (Standards and Regulations)black-gray RAL 7021
Nominal voltage, cable (Standards and Regulations)≤ 300 V
Outer sheath thickness (Standards and Regulations)approx. 0.5 mm
Outer sheath, material (Standards and Regulations)PUR
Conductor cross section (Standards and Regulations)3x 0.25 mm²
Number of bending cycles (Standards and Regulations)10000000
Cable type (abbreviation) (Standards and Regulations)PUR
External cable diameter D (Standards and Regulations)3.6 mm ±0.15 mm
Material conductor insulation (Standards and Regulations)PP
Length of twist, overall twist (Standards and Regulations)40 mm
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 80 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations)32x 0.10 mm
Core diameter including insulation (Standards and Regulations)1.17 mm ±0.02 mm
Circuit diagramContact assignment of M8 plugs/sockets (Drawings)
Dimensional drawingM8 x 1 male plug, straight version (Drawings)
Smallest bending radius, fixed installation (Standards and Regulations)18 mm
Smallest bending radius, movable installation (Standards and Regulations)36 mm
Schematic diagramPin assignment M8 socket, 3-pos., view female side (Drawings)

Product Description

Sensor/actuator cable, 3-pole, halogen-free PUR, greyish black RAL 7021, M8 straight male connector, to M8 angled connection female, cable length: 4.5 m
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Dimensional drawingM8 x 1 male plug, straight version

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide