| Parameter | Value |
|---|---|
| GTIN | 4046356673242 |
| Note | Made to Order (non-returnable) |
| (Cable) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Orderkey | 1447280 |
| Catalog page | Page 196 (C-2-2017) |
| Packing unit | 1 pc |
| (Dimensions) | IP68 |
| Country of origin | DE (Germany) |
| China RoHS (Cable) | Environmentally Friendly Use Period = 50 |
| REACh SVHC (Cable) | Lead 7439-92-1 |
| Custom tariff number | 85444290 |
| (Ambient conditions) | 60 V DC |
| Contact material (General) | CuSn |
| Material, knurls (General) | Zinc die-cast, nickel-plated |
| Coding (Ambient conditions) | A - standard |
| (Standards and Regulations) | -25 °C ... 80 °C (cable, flexible installation) |
| Material of grip body (General) | TPU, hardly inflammable, self-extinguishing |
| Standard designation (Material) | M8 connector |
| Standards/regulations (Material) | IEC 61076-2-104 |
| Degree of protection (Dimensions) | IP65 |
| Contact carrier material (General) | TPU GF |
| Contact surface material (General) | Ni/Au |
| Rated voltage (Ambient conditions) | 48 V AC |
| Status display (Ambient conditions) | No |
| Weight per Piece (excluding packing) | 243.500 g |
| Length of cable (Key Commercial Data) | 10 m |
| Cable type (Standards and Regulations) | PVC black |
| Wire colors (Standards and Regulations) | brown, blue, black |
| Cable weight (Standards and Regulations) | 29 kg/km |
| Number of positions (Ambient conditions) | 3 |
| Overall twist (Standards and Regulations) | 3 wires, twisted |
| Insulation resistance (Ambient conditions) | ≥ 100 MΩ |
| Standards/regulations (Ambient conditions) | M8 connector IEC 61076-2-104 |
| AWG signal line (Standards and Regulations) | 24 |
| Rated current at 40°C (Ambient conditions) | 4 A |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 90 °C (Plug / socket) |
| Flame resistance (Standards and Regulations) | As per UL-Style 2464 |
| Cable abbreviation (Standards and Regulations) | LiYY |
| Conductor material (Standards and Regulations) | Bare Cu litz wires |
| Test voltage, cable (Standards and Regulations) | ≤ 3000 V |
| Conductor resistance (Standards and Regulations) | max. 79 Ω/km (at 20 °C) |
| Insertion/withdrawal cycles (Ambient conditions) | ≥ 100 |
| Insulation resistance (Standards and Regulations) | ≥ 100 MΩ*km (at 20 °C) |
| Protective circuit/component (Ambient conditions) | unwired |
| Thickness, insulation (Standards and Regulations) | ≥ 0.23 mm (Core insulation) |
| External sheath, color (Standards and Regulations) | black RAL 9005 |
| Nominal voltage, cable (Standards and Regulations) | ≥ 300 V |
| Outer sheath thickness (Standards and Regulations) | ≥ 0.76 mm |
| Outer sheath, material (Standards and Regulations) | PVC |
| Conductor cross section (Standards and Regulations) | 3x 0.25 mm² (Signal line) |
| Cable type (abbreviation) (Standards and Regulations) | PVC |
| External cable diameter D (Standards and Regulations) | 4.2 mm ±0.15 mm |
| Material conductor insulation (Standards and Regulations) | PVC |
| Ambient temperature (operation) (Standards and Regulations) | -40 °C ... 80 °C (cable, fixed installation) |
| Conductor structure signal line (Standards and Regulations) | 14x 0.15 mm |
| Core diameter including insulation (Standards and Regulations) | 1.17 mm ±0.05 mm |
Technical specifications and performance data